We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

column Product List and Ranking from 68 Manufacturers, Suppliers and Companies | IPROS GMS

Last Updated: Aggregation Period:Mar 18, 2026~Apr 14, 2026
This ranking is based on the number of page views on our site.

column Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Mar 18, 2026~Apr 14, 2026
This ranking is based on the number of page views on our site.

  1. アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  2. 東ソー バイオサイエンス事業部 計測分野 Tokyo//Chemical
  3. 日本ウォーターズ(米国本社 Waters Corporation)  Tokyo//Testing, Analysis and Measurement
  4. 4 サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K. Tokyo//Testing, Analysis and Measurement
  5. 5 Sartorius Stedim Japan K.K. Tokyo//Pharmaceuticals and Biotechnology

column Product ranking

Last Updated: Aggregation Period:Mar 18, 2026~Apr 14, 2026
This ranking is based on the number of page views on our site.

  1. Innovative solid-phase extraction column Oasis PRiME HLB 日本ウォーターズ(米国本社 Waters Corporation) 
  2. ACQUITY UPLC column 日本ウォーターズ(米国本社 Waters Corporation) 
  3. The non-denaturing analysis of antibody-drug conjugates (ADCs) is settled with this! 東ソー バイオサイエンス事業部 計測分野
  4. Resolute Linear Chromatography Column Sartorius Stedim Japan K.K.
  5. 4 GC column "SE-30/SE-54" アジレント・テクノロジー株式会社

column Product List

601~630 item / All 652 items

Displayed results

Column "Select Low Sulfur"

Highly reliable quantitative results can be obtained! Mechanical stability suppresses particle detachment.

"Select Low Sulfur" is a column designed to meet the specific needs of the petrochemical field, capable of detecting sulfur compounds in propylene at low detection limits. Due to its very high inertness to volatile reactive sulfur components, it achieves extremely low detection limits. Its unique selectivity prevents co-elution and matrix interference in propylene analysis. 【Features】 ■ The column has very high inertness, achieving good peak shapes for active compounds. ■ Low detection limits for sulfur compounds. ■ Prevents co-elution and matrix interference in propylene analysis. ■ High retention of volatile components achieved through a highly permeable PLOT stationary phase. ■ Consistent column inertness achieved through a unique QC testing procedure. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-1701P"

Designed and processed for the analysis of organochlorine pesticides! Introduction of chemical bonds and cross-linking types.

The "DB-1701P" is a low/mid-polarity GC column. It has been tested to minimize pesticide degradation and ensure low ECD bleed. It can be used as a substitute for HP-PAS1701. It features chemical bonding and cross-linking, and is capable of solvent cleaning. 【Features】 ■ Low/mid polarity ■ Substitute for HP-PAS1701 ■ Specifically designed and treated for the analysis of organic chlorine pesticides ■ Tested to minimize pesticide degradation and ensure low ECD bleed ■ Solvent cleaning available *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "VF-1701 Pesticides"

Proven performance in ECD or MS detection! Improved sensitivity achieved through ultra-low bleed.

The "VF-1701 Pesticides" is a column specifically designed for the analysis of trace pesticide residues. Our columns undergo pre-shipment testing with key pesticides, including endrin and aldrin, ensuring appropriate performance and consistency of results. Additionally, they are highly deactivated for the analysis of trace pesticides, allowing for better detection limits. 【Features】 ■ Designed specifically for the analysis of trace pesticide residues ■ Individual column tests conducted using key pesticides, including endrin and aldrin ■ Enhanced detection limits for measuring trace pesticides due to advanced deactivation ■ Proven performance with ECD or MS detection ■ Improved sensitivity achieved through ultra-low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 8 CB for Pesticides"

Excellent inertness proven by tests using DDT! Providing highly reliable data.

The "CP-Sil 8 CB for Pesticides" is a column that achieves linear column response at the femtogram level. This product is equipped with an integrated retention gap, which prevents issues caused by solvent aggregation, allowing for repeated splitless injections without degrading the phase. Furthermore, the integrated retention gap prevents leaks from connections, significantly extending the column's lifespan. 【Features】 ■ Improved productivity due to linear column response down to the femtogram level ■ Proven excellent inertness through tests using DDT, providing reliable data ■ On-column injection is possible ■ The integrated retention gap prevents issues caused by solvent aggregation, allowing for repeated splitless injections without degrading the phase *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column pair 'DB-CLP1/CLP2'

Eliminate the need for column exchange! The medium-polarity stable phase enables reliable analysis with high speed and low bleed.

The "DB-CLP1/CLP2" is a highly flexible universal column pair for nine types of EPA dual ECD pesticide methods. The medium-polarity stable phase enables reliable analysis with high speed and low bleed. The reliable high-speed column provides excellent separation capability along with outstandingly low bleed, eliminating the need for time-consuming column exchanges. 【Features】 ■ Universal column pair designed for pesticide analysis ■ Suitable for dual column, dual ECD GC analysis ■ Medium-polarity stable phase enables reliable analysis with high speed and low bleed ■ Eliminates the need for time-consuming column exchanges ■ Tested with strict testing procedures, with performance summary sheets attached to all columns *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Non-polar column "HP-PAS5"

Chemical bonding and cross-linking type! Specifically designed and processed for the analysis of organic chlorine pesticides.

The "HP-PAS5" is a non-polar column specifically designed and treated for the analysis of organochlorine pesticides. The operating temperature range is -60 to 325/350°C, and it has undergone ECD testing to minimize pesticide decomposition and achieve low ECD bleed. It features chemical bonding and cross-linking, is washable with solvents, and has been tested against strict QC industry standards, providing high reliability in the accuracy and integrity of analytical results. 【Features】 ■ Non-polar ■ Specifically designed and treated for the analysis of organochlorine pesticides ■ ECD testing ensures minimal pesticide decomposition and low ECD bleed ■ Chemical bonding and cross-linking type ■ Washable with solvents *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Rapid-MS"

Outstanding sensitivity following the FactorFour VF-5ms! Compatible with any manufacturer's GC!

"Rapid-MS" is a capillary column that performs GC/MS analysis at speeds approximately 3 to 5 times faster under temperature ramp conditions and about 10 times faster under isothermal conditions. To accommodate a wide range of analyses, it is available with film thicknesses from 0.1 to 1.0 μm, while also improving the S/N ratio by about 3 times. It can be connected to any manufacturer's GC. 【Features】 ■ Maximizes productivity with rapid analysis ■ Excellent sensitivity following the FactorFour VF-5ms ■ Compatible with any manufacturer's GC (used for GC/MS) *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "VF-17ms for PAH"

The confirmation column of the EPA method, which maximizes the reliability of analysis results, is suitable!

The "VF-17ms for PAH" is a column that can separate polycyclic aromatic hydrocarbons, which are regulated by the EU and EPA, in less than 30 minutes. With inertization technology, it improves data quality and maximizes the reliability of analytical results, making it suitable as a confirmation column for EPA methods. It is a chemical bond/crosslink type that can be cleaned with solvents, helping to reduce column replacement costs. 【Features】 ■ Capable of separating polycyclic aromatic hydrocarbons regulated by the EU and EPA in less than 30 minutes ■ Improves data quality through inertization technology ■ Highly suitable as a confirmation column for EPA methods, maximizing the reliability of analytical results ■ A chemical bond/crosslink type that can be cleaned with solvents, helping to reduce column replacement costs ■ Subjected to tests based on very strict QC specifications in the industry regarding column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 88 for Dioxins"

A leak-free integrated retention gap! Extends column life when using splitless injection.

"CP-Sil 88 for Dioxins" is an ultra-high polarity column specifically designed for the separation of dioxins and dibenzofurans. It features an integrated retention gap, which prevents issues caused by solvent condensation and allows for repeated splitless injection without degrading the stationary phase. Additionally, the column's lifespan is extended, and data quality is significantly improved. 【Features】 ■ High-polarity stationary phase with selectivity specialized for the separation of dioxins and dibenzofurans ■ Integrated retention gap with no leaks, extending column lifespan during splitless injection ■ Capable of measuring low concentrations of 2,3,7,8-TCDD ■ Columns with a thin film configuration and a temperature program limit of 270°C are also available *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-624"

Chemical bonding and cross-linking type! No cryo-focusing required with U.S. EPA Method 502.2!

The DB-624 is a GC column specifically developed for the analysis of volatile contaminants. It is suitable for U.S. EPA Methods 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, and 8260. Our company continues to pursue further improvements in analytical performance standards such as separation efficiency, retention time reproducibility, and peak height ratios. 【Features】 ■ Specifically developed for the analysis of volatile contaminants ■ No cryo-focus required for U.S. EPA Method 502.2 ■ Suitable for U.S. EPA Methods 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, and 8260 ■ Excellent inertness towards active substances ■ Chemical bonding and cross-linking type *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-VRX"

A wide operating temperature range of -20 to 260℃! Introducing a low-polarity column that can be cleaned with solvents!

The "DB-VRX" is a low-polarity column designed with unique selectivity to achieve appropriate resolution for volatile compounds. It features excellent peak shape and fully complies with U.S. EPA Methods 502.2, 524.2, and 8260. This type of column, which utilizes chemical bonding and cross-linking, does not require cooling below room temperature to separate six "gases." A wide operating temperature range of -20 to 260°C is also one of its characteristics. 【Features】 ■ Unique selectivity designed to achieve appropriate separation capability in the analysis of volatile compounds: U.S. EPA Methods 502.2, 524.2, and 8260 ■ The 0.45mm inner diameter column has a greater theoretical plate count per meter than the 0.53mm inner diameter column, minimizing co-elution in GC methods ■ No cooling below room temperature is required for the separation of six "gases" ■ Fast analysis - Less than 30 minutes (with appropriate sample throughput) - Less than 8 minutes (when using a 0.18mm inner diameter column) *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Select Mineral Oil"

Available in fuse silica and UltiMetal! We also offer economical packs of 3 and 6.

The "Select Mineral Oil" column is designed for the high-speed analysis of mineral oils and features a stabilized non-polar bonded phase. It can withstand temperatures up to 375/400°C and enables high-speed analysis based on the DIN H53 and DIN-EN-ISO 9377-2 methods. With excellent temperature stability, it can analyze hydrocarbons from C4 to C40 in less than 10 minutes, significantly reducing bake-out time. 【Features】 ■ Stabilized non-polar bonded phase designed for the high-speed analysis of mineral oils ■ Appropriate selectivity that enhances the reliability of analysis results for total petroleum hydrocarbons (TPH) based on the DIN H53 N-ISO 9377-2 method ■ Capable of analyzing hydrocarbons from C4 to C40 in less than 10 minutes ■ Low bleed ■ Available in fused silica and UltiMetal *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Select Low Ammonia"

Designed for GC/NCD! Introducing a column that can obtain highly reliable qualitative/quantitative results!

The "Select Low Ammonia" column is designed to enable simple and rapid analysis of ammonia gas in light hydrocarbons using GC/NCD. This column achieves a low detection limit for ammonia at the ppbv level. Please feel free to contact us when needed. 【Features】 ■ Low detection limit for ammonia in light hydrocarbons ■ Designed for GC/NCD ■ Restrictor connected ■ It has undergone testing based on the industry's very stringent QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative and quantitative results. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 88"

High selectivity for positional isomers and geometric isomers! Separation columns for compounds with similar boiling points and polarities.

"CP-Sil 88" is a column that uses stabilized high-purity cyano-propyl as the liquid phase. It demonstrates high separation capability even for compounds with similar boiling points and polarities, such as positional isomers and geometric isomers. Please feel free to contact us when you need assistance. 【Features】 ■ High selectivity for positional isomers and geometric isomers ■ High-purity cyano-propyl liquid phase ■ Non-covalent high-polarity column *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-FFAP CB"

By using a chemical bonding type of liquid phase, we prevent the collapse of the liquid phase due to acid!

The "CP-FFAP CB" is a column that guarantees the analysis of free fatty acids. Due to its high maximum operating temperature of 250°C, it can analyze free fatty acids from C2 to C24 in a single measurement without the need for derivatization. By using a chemically bonded liquid phase, it prevents the breakdown of the liquid phase due to acids. Even with continuous injection of large amounts of water or organic solvents, the column does not get damaged. 【Features】 ■ Guarantees the analysis of free fatty acids ■ Analyzes fatty acids from C2 to C24 in one go without the need for derivatization ■ High durability against water and organic solvents ■ Chemically bonded for long lifespan *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Agilent GC columns applicable to the test items of each pharmaceutical article in GC analysis.

Publication of test items such as 'purity test (6) carbon monoxide' and 'quantitative method'!

This is an introduction to the target GC columns in accordance with the 18th revision of the Japanese Pharmacopoeia (Ministry of Health, Labour and Welfare Notification No. 220, June 7, 2021). It includes items such as "nitrous oxide" and "acethexamide" under "Pharmaceutical Articles," as well as "part numbers" and "specified columns." You can view detailed information through the related links. We encourage you to read it. 【Listed Items (Partial)】 ■ Pharmaceutical Articles ■ Test Items ■ Part Numbers ■ Names *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraBOND Q"

Introducing analysis columns for C1 to C9 hydrocarbons and halogenated compounds!

"PoraBOND Q" is a GC capillary column that can be widely used for the analysis of volatile organic solvents and hydrocarbons. This product is capable of withstanding repeated analyses of moisture-containing samples. The polymer used as the adsorbent has high purity, and even when used at 320°C, decomposition of compounds due to the adsorbent is minimal. 【Features】 ■ Provides stable data with a chemically bonded PLOT column ■ Capable of analyzing various hydrocarbons ■ Expanded maximum operating temperature *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraPLOT Q-HT"

The reproducibility of retention time is stable! Water elutes with a sharp peak, improving quantitative accuracy.

"PoraPLOT Q-HT" is a column for the analysis of volatile compounds. The maximum operating temperature has been expanded to 290°C. It can be used for applications involving halogenated compounds, hydrocarbons C1 to C6, organic solvents, and more. Please feel free to consult us when you need assistance. 【Features】 ■ Suitable for the analysis of a wide range of volatile compounds from high polarity to non-polar ■ Water elutes with sharp peaks, improving quantification accuracy ■ Stable reproducibility of retention times *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT Q"

Durable and recommended "Q" column! Good separation can be achieved in various applications.

"HP-PLOT Q" is a column made of bonded polystyrene-divinylbenzene. It can be used at a temperature limit of -60 to 270/290°C. Good separations are achieved in applications involving hydrocarbons, CO2, methane, air/CO, water, polar solvents, sulfur compounds, and more. It provides high separation in a shorter time compared to traditional packed columns. Please feel free to consult us when you need assistance. 【Features】 ■ Bonded polystyrene-divinylbenzene (DVB) column ■ A PLOT column with intermediate polarity between Porapak-Q and Porapak-N ■ A PLOT column that serves as an alternative to packed columns ■ High separation in a shorter time than traditional packed columns ■ Requires a minimum of 1 hour for conditioning *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-Q"

Separation of ethane, ethylene, and acetylene! Intermediate polarity PLOT column of Porapak-Q and Porapak-N.

The "GS-Q" is a column suitable for the analysis of gases containing fluorinated compounds and sulfur compounds. (Excluding SO2) It can be used within a temperature range of -60 to 250°C. The minimum conditioning time required is 1 hour, and it separates ethane, ethylene, and acetylene. Please feel free to contact us when you need assistance. 【Features】 ■ Porous divinylbenzene homopolymer ■ A PLOT column with intermediate polarity between Porapak-Q and Porapak-N ■ Separates ethane, ethylene, and acetylene ■ Not suitable for quantifying polar compounds ■ Minimum conditioning time: 1 hour *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT U"

It can be used in a wide range of applications such as CO2, methane, air/CO, water, solvents, alcohols, and ketones.

"HP-PLOT U" is a column with a stationary phase bonded with divinylbenzene/dimethacrylate ethylene glycol. It can be used in a wide range of applications including C1 to C7 hydrocarbons, CO2, methane, air/CO, water, dimethacrylate glycol-containing oxygen compounds, amines, solvents, alcohols, ketones, and aldehydes. Due to its high polarity, it has different selectivity and shows good peak shapes, especially for water-containing substances. 【Features】 ■ Bonded divinylbenzene/dimethacrylate ethylene glycol ■ Higher polarity than HP-PLOT Q ■ Suitable for C1 to C7 hydrocarbons, CO2, methane, air/CO, water, oxygen-containing compounds, amines, solvents, alcohols, ketones, and aldehydes ■ Provides high separation in a shorter time compared to traditional packed columns *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraPLOT U"

Prevent particle detachment as much as possible! Elute volatile compounds from high polarity to non-polar at symmetrical peaks.

"PoraPLOT U" is an analytical column for halogenated compounds, hydrocarbons, and ketones. It elutes high-polarity volatile compounds with well-symmetrical peaks. Water in the sample does not affect the retention time and does not cause broadening. Please feel free to consult us when needed. 【Features】 ■ Elutes volatile compounds from high polarity to non-polar with symmetrical peaks ■ Minimizes particle shedding *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-Alumina KCl"

Special deactivation! A versatile column suitable for the analysis of light hydrocarbons of C1 to C8 hydrocarbon isomers.

"GS-Alumina KCl" is a column that has undergone special inertization and can be rapidly regenerated. This product, which completely adsorbs water, can be regenerated at 200°C in less than 7 hours. It is also suitable for the separation of cyclopropane from propylene and is recommended as an alternative to sodium sulfide alumina due to its regenerability. 【Features】 ■ High polarity alumina phase ■ Special inertization ■ Faster, more efficient, and highly sensitive compared to equivalent packed columns ■ Minimal conditioning required ■ Recommended as an alternative to sodium sulfide alumina due to its regenerability *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT Al2O3 S"

Ideal for accurate quantitative analysis of diene! Separating propadiene and butadiene from the flow of ethylene and propylene.

The "HP-PLOT Al2O3 S" is a column that can separate gases at room temperature. It is suitable for KCI-treated inactive alumina. Different inert treatments have been applied to Al2O3, providing good resolution in hydrocarbon isomer analysis. We offer products with film thicknesses of 5.00, 8.00, and 15.00 μm. Please feel free to consult us when you need assistance. 【Features】 ■ Inactivated with KCl ■ Lower retention for olefins compared to corresponding paraffins ■ A standard column suitable for the analysis of lower hydrocarbons in C1 to C8 hydrocarbon isomers ■ Particularly suitable for accurate quantitative analysis of dienes, especially separating propyne and butadiene from the flow of ethylene and propylene *For more details, please refer to the PDF materials or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-Alumina"

High-speed, efficient, and highly sensitive! Suitable for the separation of propylene from cyclopropane.

"GS-Alumina" is a general-purpose column suitable for the analysis of light hydrocarbons in C1 to C8 hydrocarbon isomers. It is fast, efficient, and highly sensitive. Due to its regenerability, it is recommended as an alternative to sodium sulfide alumina. It is also suitable for the separation of propylene from cyclopropane. Please feel free to consult us when needed. 【Features】 ■ High polarity alumina phase ■ Special inertization ■ Fast, efficient, and highly sensitive ■ Separation of C1 to C4 saturated and unsaturated hydrocarbons ■ General-purpose column suitable for the analysis of light hydrocarbons in C1 to C8 hydrocarbon isomers *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-GasPro"

Separation of CO and CO2 in a single column! Suitable for the analysis of light hydrocarbons and sulfur gases.

The "GS-GasPro" is a column that can be used at temperature limits of -80 to 260/300°C. With its unique bonded silica PLOT column technology, it offers retention stability that is not affected by water. Agilent's commitment to reliability and reproducibility in its products supports the improvement of quality levels demanded by chromatography experts. Please feel free to consult us when needed. 【Features】 ■ Unique bonded silica PLOT column technology ■ Suitable for analysis of light hydrocarbons and sulfur gases ■ Retention stability unaffected by water ■ Separates CO and CO2 with a single column ■ Ideal PLOT column for GC/MS - does not generate particles *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-SilicaPLOT"

Separation of cyclopropane and propylene! Analysis of carbon dioxide and sulfur gas at ppm levels.

"CP-SilicaPLOT" is a column that provides high separation and fast analysis. It is ideal for the analysis of COS, CFC, hydrocarbons, propylene, and sulfur gases in ethylene. It can analyze carbon dioxide and sulfur gases at the ppm level and separate cyclopropane and propylene. Please feel free to contact us when you need assistance. 【Features】 ■ Retention time is unaffected by water ■ Analyzes carbon dioxide and sulfur gases at ppm levels ■ Separates cyclopropane and propylene *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CarboBOND"

No particle trap needed with chemical bonding type! Stability and robustness enhance the reproducibility of results.

"CarboBOND" is a column compliant with ASTM D 2505. It is suitable for the analysis of hydrocarbons in ethylene, gases in ethylene and propylene, He, Xe, CO, Ne, CH4, CO2, O2/Ar, N2, and Kr. High-boiling compounds can also be eluted in a short time, and since it is not affected by water, the reproducibility of retention times is excellent. 【Features】 ■ Column compliant with ASTM D 2505 ■ Maximum operating temperature extended to 300°C ■ Stability and robustness enhance the reproducibility of results ■ Chemical bond type, no particle trap required *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Duraguard Column

No need for press-fit connectors! Concentrate the sample at the tip of the column to achieve better peak shape.

The "Duraguard Column" incorporates deactivated fused silica, which helps avoid issues arising from connections. It is a "one-piece" guard column that does not require a press-fit connector. It minimizes contamination at the column inlet, extending its lifespan. Additionally, samples containing difficult-to-separate analytes such as pesticides or drugs can be separated without the influence of unions. 【Features】 ■ One-piece guard column ■ Minimizes contamination at the column inlet, extending column lifespan ■ Concentrates the sample at the column tip for improved peak shape ■ Minimizes contamination from the mass-selective detector (MSD) originating from the column (when used in transfer line) *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Peptide Standard Sample for Bio-pharmaceutical Analysis LC Column

Freeze-dried high recovery glass auto-sampler vials shipped with analysis certificate!

The "Peptide Standard Sample" is an LC column for biopharmaceutical analysis that contains 10 types of hydrophilic, hydrophobic, and basic peptides with a molecular weight range of 757 to 2845 Da. It is freeze-dried in high-recovery glass auto-sampler vials and shipped with an analysis certificate. Please feel free to contact us when you need it. 【Features】 ■ 10-peptide quality control standard sample ■ Hydrophilic, hydrophobic, and basic peptides ■ Molecular weight of 757 to 2845 Da ■ Freeze-dried in high-recovery glass auto-sampler vials ■ Comes with an analysis certificate *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration