We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

column×アジレント・テクノロジー株式会社 - List of Manufacturers, Suppliers, Companies and Products

column Product List

61~75 item / All 225 items

Displayed results

Volatile amine and diamine analysis column "CP-Wax"

Provides symmetrical peaks due to the inert performance of the basic reagent! Shows good inertness.

We would like to introduce our product, "CP-Wax for Volatile Amines and Diamines." It is optimized for the analysis of volatile amines and diamines, particularly C3 to C8 amines and diamines, providing symmetrical peaks due to the inert performance of basic reagents. It demonstrates good inertness towards basic compounds. Please feel free to contact us when you need assistance. 【Features】 ■ Reliable analysis of volatile amines and diamines ■ Symmetrical peaks due to the inactivation of basic reagents ■ Good inertness towards basic compounds *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Wax for Amines"

Introduction of columns compliant with EPA Method 607 featuring symmetrical peaks due to base reagent inactivation!

"CP-Wax for Amines" is a column designed for the analysis of C4 to C10 amines, diamines, and aromatic amines. It complies with EPA Method 607 and features symmetrical peaks due to the inactivation of basic reagents. Please feel free to contact us if you have any inquiries. 【Features】 ■ For the analysis of C4 to C10 amines, diamines, and aromatic amines ■ Complies with EPA 607 ■ Symmetrical peaks due to the inactivation of basic reagents *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "VF-5 Pesticides"

Guaranteeing appropriate performance and consistency of results! Advanced deactivation to enhance ECD and MS detection.

The "VF-5 Pesticides" column is specifically designed for the analysis of pesticide residues at trace concentrations. Our columns undergo pre-shipment testing with key pesticides, including endrin and aldrin, ensuring appropriate performance and consistency of results. Due to rigorous testing based on the industry's very strict QC specifications regarding column bleed, sensitivity, and efficiency, reliable qualitative and quantitative results can be obtained. 【Features】 ■ Designed specifically for the analysis of pesticide residues at trace concentrations ■ Advanced passivation to enhance ECD and MS detection ■ Achieves appropriate performance and consistency of results through testing with key pesticides, including endrin and aldrin ■ Low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 19 CB for Pesticides"

Solvent cleaning is possible with chemical bonding and cross-linking types! Suitable as a confirmation column to obtain highly reliable results.

The "CP-Sil 19 CB for Pesticides" is a column designed for the analysis of pesticides. With lower bleed than standard polymers, it not only improves the S/N ratio and minimum detectable quantity but also has a higher temperature limit, allowing for shorter analysis times. This product comes with a connection-type retention gap for on-column injection, enabling very good detection limits. 【Features】 ■ Suitable as a confirmation column for reliable results ■ Medium polarity ■ Useful as a confirmation column ■ Chemically bonded and cross-linked type, allowing for solvent washing ■ This column includes a connection-type retention gap for on-column injection, providing very good detection limits *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-608"

Chemical bonding and cross-linking type! Achieves excellent inertness and recovery rate without decomposing pesticides.

The DB-608 is a column that demonstrates excellent performance in the efficient analysis of chlorine-based pesticides and PCBs. This product, widely used in accordance with U.S. EPA Methods 608, 508, and 8080, achieves excellent inertness and recovery rates without decomposing pesticides. It features a chemical bond and cross-linking type, and is washable with solvents. 【Features】 ■ Specifically designed for the analysis of chlorine-based pesticides and PCBs ■ U.S. EPA Methods: 608, 508, 8080 ■ Excellent inertness and recovery rates without decomposing pesticides ■ Washable with solvents ■ Successor to the HP-608 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil PAH CB UltiMetal"

All 16 types of PAHs are separated according to EPA Method 610! A low bleed stationary phase with excellent thermal stability.

The "CP-Sil PAH CB UltiMetal" is a column that combines a stationary phase with excellent thermal stability and an UltiMetal stainless steel column tube. Thanks to its unique column configuration that leverages the advantages of both components, it is capable of separating all 16 types of PAHs designated by the EPA in accordance with EPA Method 610. It can also be used for fingerprint analysis and pattern recognition of complex hydrocarbon mixtures. 【Features】 ■ Separates all 16 types of PAHs according to EPA Method 610 ■ Low bleed stationary phase with excellent thermal stability ■ Extremely robust UltiMetal stainless steel capillary column ■ Supports temperatures up to 400/425°C ■ Has undergone testing based on the industry's very stringent QC specifications for column bleed, sensitivity, and efficiency, ensuring highly reliable qualitative and quantitative results. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 8 CB for PCB"

Ideal for ECD detection of trace PCBs! Excellent high-temperature stability ensures low bleed and ultra-long lifespan!

The "CP-Sil 8 CB for PCB" is a column that excels in high-temperature stability and is capable of continuous splitless injection. Due to the absence of cyano groups, it allows for ECD detection with a high S/N ratio. It is suitable for the ECD detection of trace amounts of PCBs and offers excellent high-temperature stability, resulting in low bleed and ultra-long life. 【Features】 ■ Excellent high-temperature stability, capable of continuous splitless injection ■ Designed for the analysis of PCBs based on the DIN method 51527 ■ Suitable for the ECD detection of trace PCBs ■ Excellent high-temperature stability leads to low bleed and ultra-long life ■ Subjected to testing based on the industry's very strict QC specifications for column bleed, sensitivity, and efficiency, ensuring highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-5.625"

Wide-ranging support for the analysis of basic, neutral, and acidic compounds! Cleaning with solvents is also possible.

The "DB-5.625" is a non-polar column of the chemical bonding type, enhanced in inertness and sensitivity through special processing. It is suitable as a standard column for the analysis of semi-volatile compounds using EPA methods 625, 1625, 8270, and CLP protocols. It features excellent thermal stability, a high temperature limit, and low bleed. Special testing has ensured performance that exceeds EPA performance standards for semi-volatile compounds. 【Features】 ■ Performance comparable to (5%-phenyl)-methylpolysiloxane ■ Non-polar ■ Performance exceeding EPA performance standards for semi-volatile compounds ■ Inert to basic, neutral, and acidic compounds ■ Excellent thermal stability, allowing for a high temperature limit and low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-5ms Semi-Volatile"

Demonstrates industry-leading sensitivity and consistency in the effective temperature range of -60 to 325/350℃!

The "HP-5ms Semi-Volatile" is a column that has been confirmed through testing to be inert to highly active compounds such as acidic and basic compounds. It demonstrates industry-leading sensitivity and consistency within an effective temperature range of -60 to 325/350°C. Testing is conducted based on Agilent's strict QC industry standards, and it features a chemical bond and cross-linking type, allowing for cleaning with solvents. 【Features】 ■ Has the same selectivity as HP-5 (5%-phenyl)-methylpolysiloxane ■ Non-polar ■ Ultra-low bleed suitable for GC/MS ■ Inertness to active compounds such as acidic and basic compounds confirmed through testing ■ Improved sensitivity and mass spectrum integrity due to excellent S/N ratio *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 5/C18 CB for PCB"

Designed for high-resolution analysis of PCBs! It has a C18 substituent and lower polarity than 100% polydimethylsiloxane.

The "CP-Sil 5/C18 CB for PCB" is a column with a C18 substituent that has lower polarity than 100% polydimethylsiloxane. Due to the absence of a cyano group, it allows for ECD detection with a high S/N ratio. With a 100m column, it can separate important isomer pairs 28/31, 56/60, 149/118, 105/153/132, and 170/190. 【Features】 ■ Designed for high-resolution analysis of PCBs ■ Has a C18 substituent and lower polarity than 100% polydimethylsiloxane ■ Allows for ECD detection with a high S/N ratio ■ Offers suitable column lengths for the separation of important isomer pairs 28/31, 56/60, 149/118, 105/153/132, and 170/190 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-Dioxin"

Separation of 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in a single analysis!

"DB-Dioxin" is a column designed for the analysis of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF). It is capable of separating 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in a single analysis. A 100 psi regulator is required to achieve the appropriate carrier gas flow rate. 【Features】 ■ Designed for the analysis of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) ■ Capable of separating 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in a single analysis ■ Low bleed ■ Chemical bonding and cross-linking type ■ Washable with solvent *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Select PAH"

Completely separate all PAH isomers! Provide accurate analysis results without false positives.

"Select PAH" is a capillary column that serves as a single solution for the analysis of polycyclic aromatic hydrocarbons (PAH). With excellent resolution for PAH isomers, it allows for the rapid, easy, and accurate quantification of PAHs in environmental and food samples. Since all isomers are separated in a single run, reliable analysis results without false positives can be obtained. 【Features】 ■ Completely separates all PAH isomers, providing accurate analysis results without false positives ■ Fully separates EPA-designated PAHs, including chrysene, triphenylene, and benzo(a)fluoranthene, in under 7 minutes, and EU-regulated PAHs in under 30 minutes ■ Provides rapid results in a single analysis ■ High sensitivity due to low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-EUPAH"

Designed for the analysis of PAHs regulated by the EU! Appropriate column dimensions to achieve reliable performance.

The "DB-EUPAH" column is optimized to achieve maximum performance in the analysis of all 16 types of polycyclic aromatic hydrocarbons (PAHs) regulated by the EU. Testing with application-specific QC test mixtures is conducted on all columns. It has very high thermal stability, allowing for accurate analysis of high-boiling PAHs such as dibenzopyrene. 【Features】 ■ Designed for the analysis of EU-regulated PAHs ■ Testing with application-specific QC test mixtures is conducted on all columns ■ Excellent resolution for important isomers such as benzo(b,j,k)fluoranthene ■ Very high thermal stability, allowing for accurate analysis of high-boiling PAHs such as dibenzopyrene ■ Excellent S/N ratio *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Select 624 CB"

Excellent column-to-column reproducibility! Highly reliable qualitative/quantitative results can be obtained.

The "CP-Select 624 CB" is a column that further enhances the reproducibility of the proven 624 stationary phase. Bleed is kept to 1/2 to 1/3 of that of typical columns (for a column with a length of 30m, an inner diameter of 0.53mm, and a film thickness of 3.00μm, the bleed specification is 9pA). With 6% cyanopropylphenyl and 94% dimethylpolysiloxane as the stationary phase, maximum inter-column reproducibility is ensured through rigorous synthesis based on strict standards and thorough characterization. 【Features】 ■ Reliable and precise separation of EPA-designated volatile compounds according to EPA methods 524.2, 624, and 8015. ■ Designated column for the pharmacopoeial method V.3.3.9 for residual solvent analysis, ensuring compliance. ■ Excellent inter-column reproducibility. ■ Low bleed. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Select 624 Hexane"

Since it undergoes testing based on QC specifications, highly reliable qualitative/quantitative results can be obtained!

The "CP-Select 624 Hexane" is a column designed for the separation of hexane isomers and dichloromethane, offering excellent reproducibility. Specialized QC tests for applications ensure appropriate resolution and inter-column reproducibility. Please feel free to contact us when you need assistance. 【Features】 ■ A stationary phase equivalent to USP G43 optimized for the separation of hexane isomers and dichloromethane ■ Separates acetonitrile and dichloromethane with a specified resolution of ≧1.0 according to USP <467> Residual Solvents ■ Excellent inter-column reproducibility ■ Undergoes testing based on very stringent industry QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results ■ Ensures the resolution of the CP-Select 624 Hexane column for separating dichloromethane from hexane isomers through application-specific QC tests *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration