Cleaning with solvent is possible, excellent peak shape! Highly reliable qualitative/quantitative results can be obtained!

The "HP-VOC" is a column precisely designed to exhibit excellent performance in the analysis of volatile organic compounds. The effective temperature range is -60 to 280/290°C, optimized for EPA Methods 502.2, 524.2, and 8260. This chemical bond/cross-linked type column provides high-quality peak shapes and can be used for applications requiring the analysis of purgeable or volatile organic compounds, volatile aromatic hydrocarbons, and unsaturated hydrocarbons. 【Features】 ■ Optimized selectivity for U.S. EPA Methods 502.2, 524.2, and 8260 ■ Low polarity ■ Excellent peak shape ■ Chemical bond/cross-linked type ■ Washable with solvent ■ Subjected to testing based on very stringent industry QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-502.2"

Wide temperature range! We also offer a 105m column suitable for the analysis of volatile compounds.

The DB-502.2 is a column that achieves excellent peak shape in analyses based on EPA Method 502.2. It features a chemical bond and crosslinking type, and can be cleaned with solvents. Rigorous testing based on extremely strict industry QC standards ensures that highly accurate and consistent analytical results can be obtained. Additionally, a wide operating temperature range of 0 to 260/280°C is one of the characteristics of this precisely designed product. 【Features】 - A 105m column is also available for the analysis of volatile compounds - Excellent peak shape - Chemical bond and crosslinking type - Can be cleaned with solvents - Due to testing based on the industry's very stringent QC specifications regarding column bleed, sensitivity, and efficiency, highly reliable qualitative and quantitative results can be achieved. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-MTBE"

Since it undergoes testing based on QC specifications, highly reliable qualitative/quantitative results can be obtained!

The "DB-MTBE" we handle is a column with a low-polarity stationary phase. It is of the chemical bonding and crosslinking type, allowing for cleaning with solvents. This product undergoes extensive testing based on extremely strict industry QC standards and is precisely designed to enable purge and trap injection without low-temperature concentration. It can separate MTBE from 2-methylpentane and 3-methylpentane, demonstrating excellent resolution over a temperature range of 35 to 260/280°C. 【Features】 ■ Low-polarity stationary phase ■ Separates MTBE from 2-methylpentane and 3-methylpentane, improving the reliability of quantitative results ■ Purge and trap injection possible without low-temperature concentration ■ Chemical bonding and crosslinking type ■ Cleaning with solvents is possible *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Select CB for MTBE"

Highly reliable qualitative/quantitative results can be obtained! Unique selectivity allows for easy analysis of MTBE!

Our column "CP-Select CB for MTBE" ensures highly reproducible results in the analysis of MTBE in reformulated gasoline. It features a wide dynamic range suitable for the quantification of MTBE, maximizing productivity for increasingly demanding volatile compound applications. It is ideal as a primary analysis column or as a complementary confirmation column. 【Features】 ■ Designed for the analysis of MTBE in reformulated gasoline ■ Unique selectivity for MTBE ■ Wide dynamic range suitable for the quantification of MTBE ■ Suitable as a primary column or confirmation column ■ Subjected to testing based on the industry's very stringent QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-TPH"

Temperature range of -10 to 320°C! Introducing high-speed analysis columns with chemical bonding and cross-linking types!

The column "DB-TPH" handled by our company is designed for the analysis of total petroleum hydrocarbons (TPH), soil analysis, and the analysis of leaks (LUFT) from underground fuel tanks. It can perform three analyses (gasoline range organic compounds, diesel range organic compounds, motor oil) in a single injection. It allows for solvent cleaning and is compatible with a temperature range of -10 to 320°C. Additionally, high quality is ensured through extensive QC testing, demonstrating excellent performance in petroleum analysis applications. 【Features】 ■ Designed for the analysis of total petroleum hydrocarbons (TPH), soil analysis, and LUFT analysis ■ Capable of performing three analyses (gasoline range organic compounds, diesel range organic compounds, motor oil) in a single injection ■ High-speed analysis ■ Chemical bonding and cross-linking type ■ Solvent cleaning is possible *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-FastFAME"

Corresponds to the requirements of AOAC, AOCS, and IOC regulatory methods! Chemical bonding, crosslinking type, solvent washable.

"DB-FastFAME" is a cyano-propyl phase designed for the high-speed and selective separation of both saturated and unsaturated fatty acid methyl esters (FAME). It also accommodates the separation of challenging cis-trans FAME isomers without compromising the separation capability obtained with conventional 100m columns. In less than 8 minutes, it can separate conventional FAMEs, including C18:1 and C18:2 cis/trans isomers, as well as common FAMEs such as DPA and EPA found in dairy fat, vegetable oils, and fish oils. 【Features】 ■ A cyano-propyl phase (G48) designed for the high-speed and selective separation of FAME ■ Ensures reproducibility of FAME equivalent chain length (ECL) values through individual testing with FAME mixtures ■ Complies with the requirements of AOAC, AOCS, and IOC regulatory methods ■ Chemically bonded, cross-linked type, solvent-washable ■ Intuvo specifications are also available *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-88"

Maximum temperature 250/260℃! Designed for the separation of fatty acid methyl esters (FAME).

We would like to introduce the column "HP-88" that we handle. It is designed for the separation of fatty acid methyl esters (FAME) and is highly polar. It excels in the separation of cis/trans isomers compared to "DB-23" and is designed to withstand even higher temperatures while having nearly the same selectivity as "CP-Sil 88." 【Features】 ■ (88%-cyanopropyl) methylallyl polysiloxane ■ Upper limit temperature 250/260℃ ■ High polarity ■ Designed for the separation of cis/trans fatty acid methyl esters (FAMEs) ■ Even better separation of cis-trans isomers than "DB-23" *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Smart key equipped 8890 GC column

Achieving long-term column performance and accurate separation through strict quality control specifications and testing!

Agilent Technologies, Inc. offers GC columns with smart keys. The smart key allows for monitoring of the column profile and the usage status of the GC column. Additionally, a wide range of stationary phases is available, from ultra-nonpolar and polyethylene glycol (PEG) to stationary phases tailored for specific applications. 【Features】 ■ The smart key enables automatic detection of instrument configuration and monitoring of usage status during operation, supporting the automation of method development. ■ A wide selection of stationary phases (low polarity, medium polarity, high polarity, application-specific stationary phases) is available. ■ Strict quality control specifications and testing ensure long-term column-to-column performance and accurate separations. ■ Optimization of the GC flow path with Agilent Ultra Inert liners, low bleed septa, certified vials, and gas screen filters. ■ Designed for the Agilent 8890 GC system. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Particle Trap Integrated PLOT PT Column

Analysis using GCMS and Capillary Flow Technology (CFT) is possible!

The "Particle Trap Integrated PLOT PT Column" is designed to enhance laboratory analysis work. There is no need to install a separate particle trap, allowing for leak-free analysis to be performed easily and reliably. The integrated particle trap technology is incorporated into the column as a single continuous fused silica tube. 【Features】 ■ Enables analysis using GCMS and Capillary Flow Technology (CFT), which have been difficult with PLOT columns until now. ■ No unions or traps are required for connecting a separate particle trap. ■ The integrated particle trap technology is incorporated into the column as a single continuous fused silica tube. *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraBOND U"

Expand the maximum operating temperature! Improve data accuracy and detection limit with a low bleed type.

"PoraBOND U" is a chemical bond-type PLOT column that uses a high-polarity polymer as an adsorbent. The maximum operating temperature has been expanded from 190°C to 300°C. By keeping the bleed level low, the detection limit can be lowered, and the stabilization time of the column can also be shortened. Additionally, because it is a chemical bond-type column, it can be applied to analytical methods that require pressure changes. 【Features】 ■ Expanded maximum operating temperature ■ Low bleed type improves data accuracy and detection limits ■ Chemical bond type for long lifespan *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraPLOT Q"

The reproducibility of retention time is stable! Water elutes at a sharp peak, improving quantification accuracy.

"PoraPLOT Q" is a column suitable for the analysis of a wide range of volatile compounds. This product can elute water with a sharp peak. It is capable of analyzing not only high-polarity volatile compounds but also non-polar hydrocarbons and permanent gases. Please feel free to consult us when you need assistance. 【Features】 ■ Applicable for the analysis of a wide range of volatile compounds from high polarity to non-polar ■ Elutes water with a sharp peak, improving quantification accuracy ■ Stable reproducibility of retention times *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraPLOT S"

Good reproducibility! Volatile compounds from high polarity to non-polar eluted with symmetrical peaks.

"PoraPLOT S" is a column for the analysis of hydrocarbons and ketones. It uses divinylbenzene-vinylpyridine as an adsorbent. It is suitable for the analysis of moderately polar volatile compounds that require higher temperatures than the maximum usage temperature. Please feel free to consult us when you need assistance. 【Features】 ■ Elution of volatile compounds from high polarity to non-polar with symmetrical peaks ■ Minimization of particle shedding ■ Good reproducibility *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT Al2O3 KCl"

Recommended for many ASTM methods! Suitable for KCI deactivated alumina.

The "HP-PLOT Al2O3 KCl" is a column that can separate gases at room temperature. It is suitable for the analysis of low molecular weight hydrocarbon isomers from C1 to C8. It has been treated with different inertization methods on Al2O3, providing good resolution in hydrocarbon isomer analysis. Please feel free to consult us when you need assistance. 【Features】 ■ Low polarity alumina phase ■ Inertized with KCl ■ Recommended for many ASTM methods ■ Suitable for alumina treated with KCl inertization ■ Lower retention of olefins compared to corresponding paraffins *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Al2O3/KCl"

High separation ability for hydrocarbons! Expands the scope of analysis with two polarities.

The "CP-Al2O3/KCl" is a column for the analysis of C1 to C5 hydrocarbons and impurities. It can analyze more compounds at once than packed columns, offers high separation capability, and allows for analysis in a shorter time. Compared to capillary columns using a liquid phase, it has higher selectivity and can separate C1 to C5 hydrocarbon isomers. 【Features】 ■ High separation capability for hydrocarbons ■ Short analysis time for hydrocarbons at temperatures above room temperature ■ Expands the range of analysis with two polarities *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Al2O3/Na2SO4"

High separation ability for hydrocarbons! A metal column that is resistant to physical shock.

The "CP-Al2O3/Na2SO4" is a column for the analysis of C1 to C5 hydrocarbons and impurities. It can analyze more compounds at once than packed columns, offering high separation capability and allowing for analysis in a shorter time. Compared to capillary columns using liquid phases, this product has high selectivity and can separate C1 to C5 hydrocarbon isomers. 【Features】 ■ High separation capability for hydrocarbons ■ Short analysis time for hydrocarbons at temperatures above room temperature ■ Expands analysis range with two polarities ■ Metal column resistant to physical shocks *For more details, please refer to the PDF document or feel free to contact us.