Liquid Cell Sample Stage 'TP-LQD-1'

Insert a spacer between the window materials to control thickness! A sample stage that also allows for powder measurement.

The "TP-LQD-1" is an assembly-type sample stage for liquid cells that can be mounted on the terahertz spectrometer "TeraProspector." It is used by setting it on a transmission automatic sample stage, and the cell thickness is controlled by inserting spacers between the window materials. It also allows for the measurement of powders. Two liquid cells are included as standard accessories. 【Features】 ■ Used by setting it on a transmission automatic sample stage ■ Controls cell thickness ■ Allows for the measurement of powders ■ Two liquid cells included as standard *For more details, please refer to the PDF materials or feel free to contact us.

  • Spectroscopic Analysis Equipment
  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Heating Sample Stage Unit 'TP-HEA-1'

The sample part is vacuumed for insulation! Heating stage unit for transmission measurement.

The "TP-HEA-1" is a heating stage unit for transmission measurements that can be mounted on the terahertz spectrometer "TeraProspector." The sample section is used under vacuum for insulation. The vacuum is manually created after the sample is set, and the unit, sealed under vacuum, is placed in the sample chamber for measurement. The temperature is monitored at the metal part that contacts the sample and controlled by an electric heater. A chiller is used for heat dissipation, circulating cooling water. 【Features】 ■ The sample section is used under vacuum for insulation. ■ The temperature is monitored at the metal part that contacts the sample. ■ A chiller and circulating cooling water are used for heat dissipation. *For more details, please refer to the PDF document or feel free to contact us.

  • Spectroscopic Analysis Equipment
  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Polarization Measurement Sample Stage UNIT 'TP-POL-1'

Can be mounted on a terahertz spectrometer! A stage for measuring the effects of polarization due to the sample.

The "TP-POL-1" is a stage designed to measure the effects of polarization by samples that can be mounted on the terahertz spectrometer "TeraProspector." It consists of a polarizer that cuts off components of the incident and detected signals other than the horizontal polarization component, and a sample holder that allows for the rotation of the inserted sample. 【Specifications】 ■ Model: TP-POL-1 ■ Sample rotation angle: 360° (can be set to any angle manually) ■ Extinction ratio: <10^-4 *For more details, please refer to the PDF document or feel free to contact us.

  • Spectroscopic Analysis Equipment
  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Automatic sample stage unit 'TP-TRM-1'

Continuous measurement is possible without opening the sample cover! Automatic sample stage unit.

The "TP-TRM-1" is an automatic sample stage unit that can be mounted on the terahertz spectrometer "TeraProspector." By attaching six samples to the sample mounting plate installed on the stage, continuous measurement of samples can be performed without opening the sample cover. This reduces the number of times the sample cover needs to be opened, improving measurement efficiency and minimizing the influx of water vapor. Additionally, we also offer the reflective automatic sample stage unit "TP-RFL-1." 【Features】 ■ Attach six samples to the plate (One location is used for reference measurement. The number of samples can be changed as an option.) ■ Continuous measurement of samples can be performed without opening the sample cover ■ Improves measurement efficiency and minimizes the influx of water vapor *For more details, please refer to the PDF document or feel free to contact us.

  • Spectroscopic Analysis Equipment
  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration