We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Circuit network.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Circuit network - List of Manufacturers, Suppliers, Companies and Products

Circuit network Product List

16~19 item / All 19 items

Displayed results

Pseudo power supply circuit network 'TNW-242F2' <CISPR compliant product>

Compliant with CISPR (International Special Committee on Radio Interference)! Direct measurement of interference voltage is possible.

The "TNW-242F2" is a pseudo power supply circuit network used to measure the interference voltage leaking from the power supply lines in the frequency range of 9 kHz to 30 MHz. By registering the correction factor of this device in our interference wave intensity measuring instruments (TNM-2401 and TNM-2402), automatic addition can be performed with key operations. The dimensions are 300 (W) × 130 (H) × 160 (D) mm, and the weight is approximately 4.5 kg. 【Features】 ■ CISPR compliant ■ Automatic addition with key operations is possible by registering the correction factor of this device in our interference wave intensity measuring instruments (TNM-2401 and TNM-2402) ■ Direct reading measurement of interference voltage is possible *For more details, please refer to the PDF document or feel free to contact us.

  • Other power sources
  • Other measurement, recording and measuring instruments
  • Other electronic parts

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pseudo Power Circuit Network 'TNW-243F・244F'

CISPR compliant! It can measure from single-phase to three-phase four-wire systems depending on the number of circuits of the test device.

The "TNW-243F・244F" is a pseudo power circuit network used to measure the interference voltage leaking from the power supply lines in the frequency range of 9 kHz to 30 MHz. It can measure from single-phase to three-phase four-wire systems depending on the number of lines of the device under test. The measurement line switching can be done using a remote switch in addition to the main unit's switch. Furthermore, by registering the correction factor of this device in our interference wave intensity meters (TNM-2401 and TNM-2402), automatic addition via key operation is possible. 【Features】 ■ CISPR compliant product ■ Measurement line switching can be done using a remote switch in addition to the main unit's switch ■ By registering the correction factor of this device in our interference wave intensity meters (TNM-2401 and TNM-2402), automatic addition via key operation is possible *For more details, please refer to the PDF document or feel free to contact us.

  • Other power sources
  • Other measurement, recording and measuring instruments
  • Other electronic parts

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pseudo power supply circuit network 'TNW-341F・342F・343F'

A pseudo power supply circuit network that can measure from single-phase to three-phase three-wire systems according to the number of phases of the test device!

The "TNW-341F, 342F, 343F" is a pseudo power supply circuit network used to measure the interference voltage leaking from the power supply lines in the frequency range of 150 kHz to 30 MHz. It can measure from single-phase to three-phase three-wire systems depending on the number of conductors of the device under test. By registering the correction factor of this device in our interference wave intensity measuring instruments (TNM-2401 and TNM-2402), automatic addition can be performed with key operations. 【Features】 ■ Compliant with CISPR standards ■ Measurement line switching can be done using a remote switch in addition to the main unit's switch ■ Automatic addition is possible with key operations by registering the correction factor of this device in our interference wave intensity measuring instruments (TNM-2401 and TNM-2402) ■ Direct reading measurement of interference voltage is possible *For more details, please refer to the PDF document or feel free to contact us.

  • Other power sources
  • Other measurement, recording and measuring instruments
  • Other electronic parts

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Power Supply Impedance Stabilization Circuit Network 'TNW-407F2・408F2'

"TNW-407F2" is a single-phase specification! "TNW-408F2" can measure from single-phase to three-phase three-wire system depending on the number of tracks.

The "TNW-407F2・408F2" is a power impedance stabilization circuit network used to measure the interference voltage leaking from the interference source to the power supply lines within the frequency range of 150 kHz to 30 MHz. The "TNW-407F2" is designed for single-phase use, while the "TNW-408F2" can measure from single-phase to three-phase three-wire systems depending on the number of phases of the device under test. By registering the correction factor of this device in our interference wave intensity measuring instruments (TNM-2401 and TNM-2402), automatic addition can be performed with key operations. 【Specifications (excerpt)】 <TNW-407F2> ■ Number of measurement phases: Single-phase ■ Power line rating: AC/DC 125V, 15A ■ Maximum rating: AC/DC 250V, 15A ■ Dimensions & weight: 300 (W) × 130 (H) × 160 (D) mm, approximately 4 kg *For more details, please refer to the PDF document or feel free to contact us.

  • Other power sources
  • Other measurement, recording and measuring instruments
  • Other electronic parts

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration