We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Column Product List and Ranking from 41 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Jan 07, 2026~Feb 03, 2026
This ranking is based on the number of page views on our site.

Column Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Jan 07, 2026~Feb 03, 2026
This ranking is based on the number of page views on our site.

  1. アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  2. ジーエルサイエンス 分析機器事業 Tokyo//Testing, Analysis and Measurement
  3. リスペクトシステムズ Tokyo//software
  4. 4 山善 Osaka//Machine elements and parts
  5. 4 null/null

Column Product ranking

Last Updated: Aggregation Period:Jan 07, 2026~Feb 03, 2026
This ranking is based on the number of page views on our site.

  1. GC column "SE-30/SE-54" アジレント・テクノロジー株式会社
  2. Key Management System "Key Checker" リスペクトシステムズ
  3. Column "Inject Column" 山善
  4. 4 AqasPrime column
  5. 5 GC column "DB-5" アジレント・テクノロジー株式会社

Column Product List

1~30 item / All 249 items

Displayed results

Column "Stainless Steel HPLC Empty Column"

If you're having trouble with columns, please give it a try first!

The "Stainless Steel Empty Column for HPLC" is a column that can accommodate a wide variety of HPLC applications. We offer screw-type and ferrule-type (swagelok type) options, with a standard frit filtration precision of 2µ. Additionally, it boasts a wide range of inner diameters and high internal precision, and the column ends have low diffusion. Based on years of experience and proven results, we manufacture products that meet our customers' needs. 【Features】 ■ Compatible with a wide variety of HPLC applications ■ Extensive range of inner diameters ■ High internal precision ■ Low diffusion column ends ■ High precision *For more details, please refer to the catalog or feel free to contact us.

  • Column Chromatography
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PEEK-made empty column for HPLC"

Most organic solvents, acids, and salts used in HPLC are available.

The "PEEK-made empty column for HPLC" is a column compatible with most organic solvents, acids, and salts used in HPLC. The contact part is made of inert PEEK, so there is no adsorption/denaturation of the target components or rust formation. A pressure test with water confirmed retention at 400 MPa. Additionally, a filling test at 30 MPa has also been confirmed. The inner diameter standard is the same as that of stainless steel columns, with no variation in volume, and handling is the same as that of stainless steel columns. 【Features】 ■ Withstands water pressure up to 400 MPa ■ Passes the filling test at 30 MPa ■ No adsorption/denaturation of the target components or rust formation ■ Compatible with most organic solvents, acids, and salts *For more details, please refer to the catalog or feel free to contact us.

  • Column Chromatography
  • High Performance Liquid Chromatograph
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column Comprehensive Catalog

This is a comprehensive catalog of columns for high-performance liquid chromatography.

This is the comprehensive catalog of columns from Sumika Chemical Analysis Service, Ltd.

  • Separation device
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Simplification of solid-phase extraction: Supel Swift HLB column

Achieve accurate and high-precision LC-MS analysis! It has both hydrophilic and hydrophobic functional groups.

The "Supel Swift HLB Column" is a polymer solid-phase column used for sample preparation in instrumental analysis. It retains both hydrophilic and hydrophobic functional groups to extract a wide range of compounds from aqueous samples. Additionally, its hydrophilic-lipophilic balance (HLB) characteristics allow it to retain components with various polarities and Log P values. 【Features】 ■ Fast flow rate and stability ■ Recovery rates for compounds with various Log P values ■ Reduces matrix effects and improves LC-MS analysis *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

F5 HPLC/UHPLC column

Separating structural isomers and related compounds through multiple interactions (MIX mode)!

We would like to introduce our "F5 HPLC/UHPLC Columns." These columns retain high-polarity basic compounds without the use of ion-pair reagents. They can separate related compounds such as metabolites. Additionally, they improve MS sensitivity by retaining compounds at high organic solvent concentrations, and 100% water mobile phase solvents can be used. 【Features】 ■ Retains high-polarity basic compounds without ion-pair reagents ■ 100% water mobile phase solvents can be used ■ Improves MS sensitivity by retaining compounds at high organic solvent concentrations ■ Can separate related compounds such as metabolites *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Key Management System 【Forvice Traka】

Key Management System for managing your company's important assets.

Forvice Traka is a key management system equipped with unique features not found in conventional key management boxes, designed to manage important assets. From the day you attach your keys to the dedicated key fob "iFob," only authorized individuals can retrieve the keys, and their usage history is automatically recorded. By using the management software "Traka32," you can check the history and finely set the time periods during which keys can be retrieved, as well as the number and types of keys that can be taken. Furthermore, by effectively utilizing features such as remote operation and history report generation, it lightens the management burden and enhances operational efficiency in key management. If you are having trouble with key or item management, please feel free to consult us, even for simple matters.

  • others
  • Personal authentication
  • Entrance and exit control system
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Bio LC column

High-resolution analysis of protein therapeutics.

Thermo Fisher Scientific's Bio LC columns separate biological samples with high resolution and efficiency. Our proprietary column chemical properties for biological samples are specifically designed for the separation of proteins, peptides, monoclonal antibodies, carbohydrates, nucleic acids, and more. - Protein HPLC columns - Peptide HPLC columns - Glycan HPLC columns - Oligonucleotide HPLC columns - Monoclonal antibody HPLC columns

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sampling Pump Gillian 10i/12

A compact and lightweight sampling pump that boasts excellent pressure load characteristics. It can be used for asbestos dispersion prevention measures.

It is suitable for measuring airborne asbestos and can also measure atmospheric concentration at site boundaries (construction plot boundaries), etc. It is a compact and lightweight model with a body weight of only 580 g. The pressure characteristics at a suction rate of 5 L/min are high, with the Gilian 10i at 10.0 kPa and the Gilian 12 at 14.2 kPa. It can measure with a suction flow rate of 5 L/min for 120 minutes. It comes with a variety of measurement and display functions, including alert displays to prevent the collection of faulty data and a fault function that automatically stops suction.

  • Other environmental analysis equipment
  • Other pumps
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Glycan Separation Technology Column

It is optimal for UPLC analysis of fluorescent (2-AB) labeled glycans with a stable amide column.

Glycoprotein analysis requires the identification of complex N-linked and O-linked structures consisting of repetitive similar sugar components. Hydrophilic interaction chromatography (HILIC) utilizing fluorescence detection is a highly reliable analytical method that effectively separates and quantifies glycan chains labeled with fluorescent labeling reagents. The Waters Glycan Separation Technology column is a dedicated QC-tested column developed for the rapid analysis of various glycan structures with excellent UPLC(R) separation capability. By combining the Waters ACQUITY UPLC(R) system with column chemistry, accurate analytical results can be obtained more quickly. 【Features】 ○ Shorter time and higher separation capability compared to conventional HPLC methods ○ Ideal for use with the ACQUITY UPLC fluorescence detection system ○ Stable and reproducible separation of labeled glycan chains Waters BEH particles and functional group bonding technology ○ QC tests using labeled glycan standards are conducted to ensure consistent column performance between batches For more details, please contact us or download the catalog.

  • Other laboratory equipment and containers
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC and GC/MS columns

Minimal downtime! Achieves excellent performance with high reproducibility even for samples that are difficult to analyze!

Agilent has been leading innovations in gas chromatography for over 40 years, introducing groundbreaking products. We also offer a comprehensive range of columns and consumables for GC and GC/MS in the industry. The Agilent J&W Ultra Inert GC columns are tested using rigorous industry-standard probes, achieving low detection limits and providing high-precision data for challenging target compounds. Our GC and GC/MS cover the essential elements required for trace analysis, dramatically improving the separation capability of MS, spectral integrity, and detection limits. 【Column Analysis Equipment Lineup (Partial)】 ■Agilent 7890B GC ■Agilent 7820A GC ■Agilent 6850 Series II GC ■Agilent 7697A Headspace Sampler ■Agilent 490 Micro GC and 490-PRO *For more details, please refer to the PDF materials or feel free to contact us.

  • Gas recovery/treatment equipment
  • Separation device
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Agilent J&W Ultra Inert GC/MS Column

Introducing a column that reduces noise and suppresses peak tailing of active compounds!

The "Agilent J&W Ultra Inert GC/MS Column" minimizes peak tailing and baseline rise of active compounds, providing excellent analytical results. Current laboratories are under increasing pressure to comply with rapidly growing regulations while delivering accurate results quickly. By using this product, you can improve the detection limits for challenging target compounds. 【Features】 ■ Detection of active compounds at trace concentrations ■ Minimal peak tailing for active analytes ■ Longer maintenance-free time, which is crucial for the equipment ■ Minimal loss and degradation of compounds for more accurate quantification *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Agilent J&W DB-WAX Ultra Inert GC Column

No need for analysis in individual FFAP columns! By standardizing, it can accommodate a wide range of applications.

The "Agilent J&W DB-WAX Ultra Inert GC Column" features extremely high inertness, providing more reliable peak shapes and excellent durability compared to standard WAX columns. In the analysis of active compounds, adsorption in the flow path significantly impacts the reliability of the analytical results. This product alleviates concerns associated with the analysis of polar compounds. 【Features】 ■ Reduces the need for troubleshooting and reanalysis ■ Saves costs on columns ■ Eliminates the need for pre-qualification of columns ■ Facilitates method conversion ■ Maintains exceptional inertness even after exposure to 250°C for 50 hours *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

DB-WAX Ultra Inert GC Column <High Reliability for Analysis>

It is suitable for chemical analysis in spice applications, quality control labs, and method development labs!

The "Agilent J&W DB-WAX Ultra Inert GC Column" dispels concerns associated with the analysis of polar compounds. It achieves excellent peak shape, reliable column-to-column reproducibility of inertness, and more stable retention times. Moreover, even after repeated temperature cycling up to the column's maximum temperature, excellent inertness is maintained over the long term. 【Features】 ■ Excellent peak shape for acidic compounds ■ Stable inert performance for alcohols and glycols ■ Excellent durability for water-soluble samples ■ Easy upgrade to more reliable qualitative and quantitative methods *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-UI 8270D Ultra Inert"

Excellent peak shape at low concentration! Individually tested at low temperatures using highly verifiable semi-volatile compounds.

We would like to introduce the GC column "DB-UI 8270D Ultra Inert" that we handle. When used for the analysis of semi-volatile organic compounds targeted by EPA Method 8270D, it provides excellent peak shapes, thereby enhancing the reliability of trace analysis in the environmental field. Thanks to Agilent's advanced manufacturing processes, optimized chemistry, and design advancements, both inertness and column-to-column reproducibility are improved, and there is no reduction in bleed or selectivity of the stationary phase. 【Features】 - Industry-leading Ultra Inert treatment and manufacturing - Highly reliable results through excellent testing protocols - "MS Grade" low bleed stationary phase minimizes interference from the column even at high temperatures *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "CP-Sil 5 CB"

We offer two types: fused silica and metal columns! GC columns with a wide usable temperature range!

The "CP-Sil 5 CB" is a column that contains 100% dimethylpolysiloxane as the liquid phase. Separation is based on the boiling points of the compounds and can be applied over a wide temperature range. This chemically bonded product has high inertness, can withstand large injections, and can be used with good reproducibility. 【Features】 ■ Contains 100% dimethylpolysiloxane as the liquid phase ■ Separation is based on the boiling points of the compounds ■ Helps reduce costs ■ Applicable to various analyses ■ Available in two types: fused silica and metal columns *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "HP-17"

Reliable qualitative/quantitative results can be obtained! No need for crosslinked polymers or chemically bonded polymers.

We would like to introduce our product, the 'HP-17'. It is a 50% phenyl / 50% methyl siloxane phase and is not a chemically bonded or crosslinked type. Therefore, this product can be used in established methods where crosslinked polymers or chemically bonded polymers are not required. Since this product is neither chemically bonded nor crosslinked, solvent cleaning is not recommended. 【Features】 ■ 50% phenyl and 50% methyl siloxane ■ It has undergone testing based on the industry's very strict QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative and quantitative results. ■ For details on QC test conditions, including test mixtures and chromatograms of results, please refer to the Agilent J&W GC Column Performance Summary included with each GC column. *For more information, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "HP-50+"

Solvent washable! For the analysis of polar compounds such as chlorine-based pesticides, herbicides, and basic drugs!

We would like to introduce the 'HP-50+' that we handle. This product, which is a medium polarity column, is generally used for the analysis of polar compounds such as chlorine-based pesticides, herbicides, and basic drugs. It is used as a second column for confirming qualitative results. Additionally, since the 0.32mm series is also effective with the 0.20mm series, methods can be easily transferred to GC/MS equipment. 【Features】 ■ (50%-Phenyl) Methylpolysiloxane ■ Slightly lower polarity than medium polarity (DB-17) ■ Suitable for confirmation analysis ■ Chemical bonding and cross-linking type ■ Solvent cleanable ■ Equivalent to USP Phase G3 *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "CP-Sil 24 CB"

It shows good peak shape in the analysis of amines! Suitable for the analysis of pharmaceuticals and pesticides.

The "CP-Sil 24 CB" is a medium-polarity GC column that uses a liquid phase of 50% phenyl and 50% dimethyl polysiloxane. Since it does not contain cyano-propyl in the liquid phase, it is suitable for detection using ECD. Additionally, this column shows good peak shapes in the analysis of amines. It is particularly suitable for the analysis of pharmaceuticals and pesticides, and when used in combination with CP-Sil 5 CB or CP-Sil 8 CB as a confirmation column, the reliability of the data is further enhanced. 【Features】 ■ Chemically bonded liquid phase for long lifespan ■ Improved sensitivity when using ECD ■ Provides high-precision data with good inertness *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "HP-101"

Available for established methods! Highly reliable qualitative/quantitative results can be obtained.

We would like to introduce our product, 'HP-101'. It is a 100% dimethylpolysiloxane phase. Since it is neither chemically bonded nor cross-linked, it can be used in established methods that employ columns without cross-linked or chemically bonded polymer phases. As this product is neither chemically bonded nor cross-linked, solvent washing is not recommended. 【Features】 ■ 100% dimethylpolysiloxane ■ It has undergone testing based on very stringent QC specifications in the industry regarding column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative and quantitative results. ■ For details on the QC test conditions, including test mixtures and chromatograms of results, please refer to the Agilent J&W GC Column Performance Summary included with each GC column. *For more information, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-225"

Excellent for the separation of cis- and trans-fatty acid methyl esters (FAMEs)! Alternative to HP-225.

We would like to introduce the GC column "DB-225" that we handle. It is a (50% cyanopropylphenyl) dimethylpolysiloxane, with medium/high polarity. It excels in the separation of cis- and trans-fatty acid methyl esters (FAMEs). It is a chemically bonded and cross-linked type, allowing for solvent cleaning. 【Features】 ■ (50% cyanopropylphenyl) dimethylpolysiloxane ■ Medium/high polarity ■ Chemically bonded and cross-linked type ■ Solvent cleaning possible ■ Alternative to HP-225 ■ Equivalent to USP Phase G7 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "CP-Sil 43 CB"

An ideal column for the analysis of inductively coupled compounds! Separating aliphatic and aromatic compounds.

We would like to introduce the GC column "CP-Sil 43 CB" that we handle. It is a chemically bonded medium-polarity GC column with a liquid phase consisting of 25% cyanopropyl, 25% phenyl, and 50% dimethylpolysiloxane. It is equivalent to the OV-225 stationary phase used in packed columns and efficiently separates aliphatic and aromatic compounds. 【Features】 ■ Medium-polarity column with distinctive selectivity ■ Separates aliphatic and aromatic compounds ■ Long lifespan with chemically bonded liquid phase *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "CP-1301"

Excellent reproducibility and good deactivation! Thin film GC columns suitable for the analysis of herbicides, pesticides, and pharmaceuticals.

We would like to introduce the GC column "CP-1301" that we handle. This column features a non-covalently bonded phase consisting of 6% cyanopropylphenyl and 94% dimethylpolysiloxane. This medium-polarity column is suitable for the analysis of herbicides, pesticides, and pharmaceuticals. 【Features】 ■ Column with a non-covalently bonded phase of 6% cyanopropylphenyl and 94% dimethylpolysiloxane ■ Medium-polarity thin film GC column ■ Excellent reproducibility ■ Good inertness *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-WaxFF"

Chemical bonding and cross-linking type! Exhibits excellent performance, especially in complex fragrance analysis.

"DB-WaxFF" is a microbore column of Agilent's standard DB-Wax column, specially tested to maximize reproducibility between columns. It demonstrates excellent performance, particularly in complex fragrance analyses. The lower temperature limit is 20°C, which improves the separation of low-boiling compounds. The reproducibility between columns is significantly superior to other microbore columns. 【Features】 ■ Polyethylene glycol (PEG) ■ Equivalent to USP Phase G16 ■ High polarity ■ Chemical bonding/cross-linking type ■ Alternative to HP-WAX ■ Solvent washability *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-FFAP CB"

It is possible to analyze free fatty acids from C2 to C24 in a single measurement without derivatization!

The "CP-FFAP CB" is a column that guarantees the analysis of free fatty acids. Due to its high maximum operating temperature of 250°C, it is possible to analyze free fatty acids from C2 to C24 in a single measurement without the need for derivatization. By using a chemically bonded liquid phase, it prevents the breakdown of the liquid phase due to acids. Even with large continuous injections of water or organic solvents, the column does not get damaged. 【Features】 ■ Guarantees the analysis of free fatty acids ■ Analyzes fatty acids from C2 to C24 in one go without the need for derivatization ■ High durability against water and organic solvents ■ Chemically bonded for long lifespan *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Carbowax 20M/HP-20M"

Temperature range is 60 to 220°C! Suitable for alcohol, free acids, ethers, glycols, and solvents.

"Carbowax 20M/HP-20M" is a polyethylene glycol (PEG) column equivalent to USP Phase G16. The temperature range is 60 to 220°C, suitable for alcohols, free acids, ethers, glycols, and solvents. Since it is neither chemically bonded nor cross-linked, solvent washing is not recommended. DB-WAX is chemically bonded and can be used as a substitute for HP-20M. 【Features】 ■ Polyethylene glycol, MW 20,000 ■ Equivalent to USP Phase G16 ■ All of our GC columns undergo testing based on the industry's very strict QC specifications regarding column bleed, sensitivity, and efficiency ■ Capable of obtaining highly reliable qualitative/quantitative results ■ Equivalent product: Rt-CW20M F&F *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CAM"

Base-inactive treated polyethylene glycol! Designed specifically for amine analysis.

The "CAM" is a column that can achieve excellent peak shape for primary amines. It can be used as a substitute for HP-BasicWax. Since this column is neither bonded nor cross-linked, solvent washing is not recommended. It is made of base-inactive treated polyethylene glycol and is specifically designed for amine analysis. 【Features】 ■ Base-inactive treated polyethylene glycol ■ Specifically designed for amine analysis ■ Excellent peak shape for primary amines ■ Can be used as a substitute for HP-BasicWax ■ All of our GC columns undergo testing based on the industry's very strict QC specifications for column bleed, sensitivity, and efficiency ■ Capable of obtaining highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Lowox"

Unique selectivity for a wide range of oxygen-containing compounds! Suppressing particle detachment and maintaining detector performance.

"Lowox" is a highly polar column suitable for the measurement of oxygen-containing compounds. It provides solutions for the chemical and petrochemical industries, particularly suitable for trace analysis of oxidizing impurities contained in gas and liquid hydrocarbon streams. It is appropriate for preventing catalyst contamination by oxygen-containing compounds and for process/online applications (such as measuring methanol in crude oil in accordance with ASTM D7059). 【Features】 ■ Unique selectivity for a wide range of oxygen-containing compounds ■ Suppresses particle shedding to maintain detector performance ■ Proven performance in process and portable GC applications (ASTM D 7059) ■ Analyzes trace levels of oxidizing impurities in gas and liquid hydrocarbon streams ■ Highly polar ■ Suitable for monitoring catalyst contamination by oxygen-containing compounds *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-Petro"

Cleaning with solvent is possible! Introducing columns with chemical bonds and cross-linking types.

"DB-Petro" is a 100% dimethylpolysiloxane phase precisely designed for the analysis of PONA, PIANO, and PNA generated in petroleum processing. It allows for solvent cleaning with chemical bonding and crosslinking types. It has also been tested based on the industry's very strict QC standards. One of its features is a wide operating temperature range of -60 to 325/350°C, enabling highly reliable qualitative and quantitative results regarding column bleed, sensitivity, and efficiency. 【Features】 ■ 100% dimethylpolysiloxane ■ PONA, PIANO ■ High separation capability ■ Chemical bonding, crosslinking type ■ Solvent cleaning possible *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-2887"

Low bleed with high-speed analysis! Introducing columns that allow solvent cleaning with chemical bonds and crosslinking types.

The DB-2887 is a column specially designed for pseudo-distillation in accordance with ASTM method D2887. It features fast conditioning, rapid analysis, and low bleed, with a chemical bond and cross-linked type, and excellent performance between columns. With a wide operating temperature range (-60 to 350°C) and tested based on the industry's very strict QC standards, it stands out for its performance and ease of use, and solvent washing is also possible. 【Features】 ■ 100% Dimethylpolysiloxane ■ Specially designed for pseudo-distillation (SIMDIS) using ASTM method D 2887 ■ Faster conditioning and analysis with lower bleed compared to packed columns ■ Chemical bond and cross-linked type, allowing for solvent washing ■ Capable of obtaining highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 5 CB for Sulfur"

Achieving high-quality data and low detection limits! Providing accurate analytical results based on volatility.

The "CP-Sil 5 CB for Sulfur" is a column optimized for the analysis of volatile sulfur compounds. It achieves high productivity in trace analysis of sulfur compounds up to C7 mercaptans. With a non-polar phase, it can accurately separate based on volatility. High inertness allows for the elution of sulfur dioxide, resulting in high-quality data and low detection limits. 【Features】 ■ Optimized for the analysis of volatile sulfur compounds ■ Achieves high productivity in trace analysis of volatile sulfur compounds up to C7 mercaptans ■ Provides accurate analytical results based on volatility due to the non-polar phase ■ Achieves high-quality data and low detection limits through the elution of SO2 due to high inertness ■ Capable of obtaining highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration