We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Column Product List and Ranking from 41 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Jan 07, 2026~Feb 03, 2026
This ranking is based on the number of page views on our site.

Column Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Jan 07, 2026~Feb 03, 2026
This ranking is based on the number of page views on our site.

  1. アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  2. ジーエルサイエンス 分析機器事業 Tokyo//Testing, Analysis and Measurement
  3. リスペクトシステムズ Tokyo//software
  4. 4 山善 Osaka//Machine elements and parts
  5. 4 null/null

Column Product ranking

Last Updated: Aggregation Period:Jan 07, 2026~Feb 03, 2026
This ranking is based on the number of page views on our site.

  1. GC column "SE-30/SE-54" アジレント・テクノロジー株式会社
  2. Key Management System "Key Checker" リスペクトシステムズ
  3. Column "Inject Column" 山善
  4. 4 AqasPrime column
  5. 5 GC column "DB-5" アジレント・テクノロジー株式会社

Column Product List

151~180 item / All 249 items

Displayed results

C18 column "CP-Sil 19 CB"

Applicable to various analyses in the fields of environment, food and beverages, and pharmaceuticals! Cyanopropyl-based medium-polarity column.

We would like to introduce our medium-polarity column, 'CP-Sil 19 CB'. This product features a liquid phase of 14% cyanopropylphenyl and 86% dimethylpolysiloxane, demonstrating different elution behavior compared to phenyl/dimethylpolysiloxane liquid phase columns. It can be applied to various analyses in the fields of environment, food and beverages, and pharmaceuticals. 【Features】 ■ Highly reliable confirmation column ■ Chemically bonded liquid phase for long lifespan ■ Various column sizes available *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

WAX column "DB-HeavyWAX"

The retention time remains stable even at the highest operating temperature! Extended column lifespan has been achieved.

The 『DB-HeavyWAX』 polyethylene glycol (PEG) column is a high-temperature WAX column that can be used at higher temperatures than standard WAX columns. The increase in maximum operating temperature shortens analysis time, reducing the cost per analysis. Even at the maximum operating temperature, the retention time remains stable, extending the column's lifespan. The column's empty bake at the end of the analysis reduces sample carryover and suppresses ghost peaks. 【Features】 ■ Selectivity of polyethylene glycol ■ Maximum operating temperature: 280°C for isothermal analysis, 290°C for temperature-programmed analysis ■ Fast analysis: Shortened analysis time due to increased temperature limits ■ Stable retention time at maximum operating temperature, extending column lifespan *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-WAX"

The lower temperature limit is 20°C! It is low even among PEG-bound phases, improving the decomposition degree of low boiling point compounds.

We would like to introduce the GC column "DB-WAX" that we handle. It is equivalent to Polyethylene Glycol (PEG) USP Phase G16 and has high polarity. The lower temperature limit is 20°C, which is low among PEG bonded phases and improves the decomposition of low boiling point compounds. It offers column-to-column reproducibility and is a chemical bonded/cross-linked type, serving as an alternative to HP-WAX. 【Features】 ■ Equivalent to Polyethylene Glycol (PEG) USP Phase G16 ■ High polarity ■ Lower temperature limit of 20°C ・Low among PEG bonded phases, improving the decomposition of low boiling point compounds ■ Column-to-column reproducibility ■ Chemical bonded/cross-linked type *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Wax 52 CB"

High polarity - Achieving separation for a wide range of applications! Excellent reproducibility of column inertness.

"CP-Wax 52 CB" has a special cross-linked structure, allowing for a lower minimum temperature and a higher maximum temperature compared to non-bonded polyethylene glycol (PEG) columns, thereby improving the separation capability of low boiling point compounds. With guaranteed reproducibility and excellent temperature stability, CP-Wax 52 CB is suitable for EPA methods and ASTM methods. It achieves sharp, symmetrical peak shapes for highly active polar compounds. 【Features】 ■ Polyethylene glycol (PEG) phase ■ High polarity - enables separation across a wide range of applications ■ Excellent reproducibility of inertness between columns ■ Achieves sharp, symmetrical peak shapes for highly active polar compounds ■ Solvent-cleanable with chemical bonding and cross-linking type *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-FFAP"

Temperature range is 40 to 250℃! Introducing columns that allow solvent cleaning with chemical bonding and cross-linking types.

The "DB-FFAP" is a column designed for the analysis of volatile fatty acids and phenols. It has high polarity and a temperature range of 40 to 250°C. It serves as a substitute for OV-351. It features chemical bonding and cross-linking types, allowing for solvent washing. It is equivalent to SP Phase G35. Please feel free to contact us when you need assistance. 【Features】 ■ Nitroterephthalic acid modified polyethylene glycol ■ High polarity ■ Temperature range: 40 to 250°C ■ Designed for the analysis of volatile fatty acids and phenols ■ Substitute for OV-351 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-17ht"

A high temperature limit of 365℃! Achieving excellent peak shape and rapid elution with high boiling point compounds.

The "DB-17ht" is a column suitable for precise confirmation analysis over a wide temperature range. This medium-polarity column can be cleaned with solvents and is equipped with a polyimide-coated fused silica tube. It demonstrates excellent peak shape even in high-temperature operating environments. Additionally, it features rapid elution of high-boiling compounds. It is manufactured stably and efficiently using high-quality materials and processes. 【Features】 ■ (50%-Phenyl)-Methylpolysiloxane ■ Medium polarity ■ High temperature limit of 365℃ ■ Polyimide-coated fused silica tube for high temperatures ■ Achieves excellent peak shape and rapid elution for high-boiling compounds *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "VF-5ht"

Improvement of detection limits due to enhanced detector performance! Optimizing sensitivity and accuracy for the analysis of high molecular weight compounds.

The "VF-5ht" is a column suitable for analyzing high boiling point compounds at high temperatures with low bleed. It is based on ultra-low bleed technology, demonstrating high selectivity, sensitivity, and accuracy in the analysis of high molecular weight compounds. The temperature range is -60 to 400°C for fused silica and -60 to 450°C for UltiMetal stainless steel. 【Features】 ■ Improved stability extends column life and reduces downtime ■ Enhanced detector performance improves the detection limit ■ Maintains ultra-low bleed even at high temperatures, making it ideal for analyzing high boiling point compounds ■ Optimized sensitivity and accuracy for the analysis of high molecular weight compounds ■ Same selectivity as VF-5ms (bleed specification for 30m×0.25mm column is <5pA at 400°C) *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column CP-Sil 5 CB for Formaldehyde

Optimized for the analysis of formaldehyde, water, and methanol! High-efficiency non-polar column with membrane thickness.

"CP-Sil 5 CB for Formaldehyde" is a column capable of trace analysis of sulfur compounds. It is optimized for the analysis of formaldehyde, water, and methanol, and is suitable for trace analysis of sulfur compounds and some permanent gases (especially in switching systems). With a non-polar phase, it can achieve accurate separation based on volatility. 【Features】 ■ Optimized for the analysis of formaldehyde, water, and methanol ■ Capable of trace analysis of sulfur compounds ■ Capable of analyzing some permanent gases (especially in switching systems) ■ Achieves accurate separation based on volatility with a non-polar phase ■ Provides high-quality data with low detection limits by eluting sulfur components without adsorption and with high inertness ■ High-efficiency non-polar column with a thick film *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PONA"

Configured for the analysis of petroleum products! It has very high separation ability, making it suitable for detailed analysis of petroleum products.

"HP-PONA" is a 100% dimethyl polysiloxane column that allows solvent washing with a chemical bond and cross-linking type. It has very high separation capability, making it suitable for detailed analysis of petroleum products. Additionally, it has been tested based on the industry's very strict QC standards during manufacturing. Furthermore, it has also been tested for the separation capability of p-xylene and m-xylene, as well as 2,3-dimethylbutane and cyclopentane. 【Features】 ■ 100% dimethyl polysiloxane ■ Designed for analysis of petroleum products ■ Tested for separation capability of p-xylene and m-xylene, as well as 2,3-dimethylbutane and cyclopentane ■ PONA, PIANO ■ High separation capability *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-SimDist"

Achieving long lifespan for the column! Stable liquid phase at high temperatures and polyimide coating!

The "CP-SimDist" is a column specialized for pseudo-distillation (SIMDIS) analysis up to C100. It features low bleed, with a bleed level of 4-5 pA at 400°C. The stable liquid phase at high temperatures and polyimide coating contribute to the longevity of the column. For details on QC test conditions, including test mixtures and resulting chromatograms, please refer to the "Agilent J&W GC Column Performance Summary" included with each GC column. 【Features】 ■ Supports pseudo-distillation analysis up to C100 ■ High-temperature non-polar stationary phase ■ Excellent quantification due to low bleed ■ Long lifespan achieved with high-temperature polyimide coating ■ Capable of obtaining highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column 'Select Al2O3 MAPD'

Improved operational efficiency! Specializing in the analysis of methylacetylene and propadiene (MAPD).

"Select Al2O3 MAPD" is an alumina PLOT column suitable for the analysis of reactive hydrocarbons. It is stable up to 200°C and can analyze hydrocarbons up to C10. The adsorption of reactive (polar) hydrocarbons and the unstable response are significantly improved. It has up to twice the response for MAPD, making it particularly important for impurity analysis. 【Features】 ■ Suitable for the analysis of reactive hydrocarbons ■ Optimized to enhance sensitivity and response ■ Improved operational efficiency through faster analysis ■ Particularly important for impurity analysis, with twice the response for MAPD ■ Capable of obtaining highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Biodiesel"

Maintains excellent peak shape and long column life! Achieves leak prevention and ease of connection.

Biofuels are gaining attention as fuels that complement or serve as alternatives to petroleum-based fuels. This product is designed for biodiesel analysis, optimized for specific applications, and complies with ASTM and CEN testing standards. It demonstrates excellent performance in the analysis of free glycerin, total glycerin, FAME, and trace methanol. 【Features】 ■ Complies with EN14105, ASTM D6584, EN14103, EN14110, EN14331 methods ■ Chemical bond and crosslinking type ■ Capable of obtaining highly reliable qualitative/quantitative results ■ Specially treated for a temperature limit of 400°C ■ Fused silica tubes coated with polyimide for high-temperature use *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Select BioDiesel"

Achieving high precision and durability! The retention gap has undergone leak testing!

"Select BioDiesel" addresses the important challenge of extending the lifespan of columns used at very high temperatures of up to 400°C. While conventional fused silica can be used, in many cases, high temperatures shorten the lifespan of the column. By using UltiMetal columns along with a highly stable stationary phase, the consistency of results is improved, and column damage is virtually eliminated. [Features] ■ High precision and durability achieved through UltiMetal technology ■ Reliable analytical results ensured through pre-testing ■ Excellent column lifespan during operation at up to 400°C ■ UltiMetal columns with superior stability in stationary phase ■ Convenient pre-connected retention gap that has undergone leak testing *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Select Silanes"

Available for use with splitless injection! The peak shape improves due to low surfactant activity.

This product is a column that enables the analysis of silanes at ppm levels through a stabilized trifluoropropyl-methyl polysiloxane phase. The film thickness is very thick, achieving a large capacity and high retention capability for volatile silanes. Due to low bleed, composition analysis and impurity analysis can be performed down to ppm levels, and the low surface activity improves peak shape. Typical applications include % level or trace impurity analysis targeting alkylated chlorosilanes. 【Features】 ■ Large capacity and high retention capability ■ Low bleed ■ Excellent peak shape achieved by reducing surface activity ■ High sample holding capacity and retention capability provided by thick film thickness ■ Usable with valves, direct, split/splitless injection ports *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Volamine"

Available for a wide range of applications! Provides sharp amine peaks.

"CP-Volamine" is a column optimized for the separation of volatile amines. Coated with a non-polar stationary phase, it generates symmetrical peaks through MPD (Multi-Purpose Deactivation) technology. It is highly stable and can analyze volatile amines even when the sample contains a high percentage of water. 【Features】 ■ Non-polar stationary phase ■ Excellent stability for samples containing water ■ Improved productivity with a maximum temperature of 265°C ■ Provides sharp amine peaks with accurate results due to high inertness ■ Exhibits excellent performance even when the sample contains water *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 8 CB for Amines"

Separable alkanolamines! Obtain highly reliable qualitative/quantitative results.

We would like to introduce our product, 'CP-Sil 8 CB for Amines.' It has thermal stability up to 350°C and can be used for the analysis of various amines, particularly C3 to C20 and alkanolamines. For details on QC test conditions, including test mixtures and chromatograms, please refer to the Agilent J&W GC Column Performance Summary that comes with each GC column. 【Features】 ■ Base-inactive treated 5% phenyl polysiloxane ■ Optimized inertness for a variety of amine compounds ■ Thermal stability up to 350°C ■ Capable of separating amines and alkanolamines up to C20 ■ Base-inactive treated columns are also available as CP-Wax for Amines *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "VF-5 Pesticides"

Guaranteeing appropriate performance and consistency of results! Advanced deactivation to enhance ECD and MS detection.

The "VF-5 Pesticides" column is specifically designed for the analysis of pesticide residues at trace concentrations. Our columns undergo pre-shipment testing with key pesticides, including endrin and aldrin, ensuring appropriate performance and consistency of results. Due to rigorous testing based on the industry's very strict QC specifications regarding column bleed, sensitivity, and efficiency, reliable qualitative and quantitative results can be obtained. 【Features】 ■ Designed specifically for the analysis of pesticide residues at trace concentrations ■ Advanced passivation to enhance ECD and MS detection ■ Achieves appropriate performance and consistency of results through testing with key pesticides, including endrin and aldrin ■ Low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 19 CB for Pesticides"

Solvent cleaning is possible with chemical bonding and cross-linking types! Suitable as a confirmation column to obtain highly reliable results.

The "CP-Sil 19 CB for Pesticides" is a column designed for the analysis of pesticides. With lower bleed than standard polymers, it not only improves the S/N ratio and minimum detectable quantity but also has a higher temperature limit, allowing for shorter analysis times. This product comes with a connection-type retention gap for on-column injection, enabling very good detection limits. 【Features】 ■ Suitable as a confirmation column for reliable results ■ Medium polarity ■ Useful as a confirmation column ■ Chemically bonded and cross-linked type, allowing for solvent washing ■ This column includes a connection-type retention gap for on-column injection, providing very good detection limits *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-608"

Chemical bonding and cross-linking type! Achieves excellent inertness and recovery rate without decomposing pesticides.

The DB-608 is a column that demonstrates excellent performance in the efficient analysis of chlorine-based pesticides and PCBs. This product, widely used in accordance with U.S. EPA Methods 608, 508, and 8080, achieves excellent inertness and recovery rates without decomposing pesticides. It features a chemical bond and cross-linking type, and is washable with solvents. 【Features】 ■ Specifically designed for the analysis of chlorine-based pesticides and PCBs ■ U.S. EPA Methods: 608, 508, 8080 ■ Excellent inertness and recovery rates without decomposing pesticides ■ Washable with solvents ■ Successor to the HP-608 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil PAH CB UltiMetal"

All 16 types of PAHs are separated according to EPA Method 610! A low bleed stationary phase with excellent thermal stability.

The "CP-Sil PAH CB UltiMetal" is a column that combines a stationary phase with excellent thermal stability and an UltiMetal stainless steel column tube. Thanks to its unique column configuration that leverages the advantages of both components, it is capable of separating all 16 types of PAHs designated by the EPA in accordance with EPA Method 610. It can also be used for fingerprint analysis and pattern recognition of complex hydrocarbon mixtures. 【Features】 ■ Separates all 16 types of PAHs according to EPA Method 610 ■ Low bleed stationary phase with excellent thermal stability ■ Extremely robust UltiMetal stainless steel capillary column ■ Supports temperatures up to 400/425°C ■ Has undergone testing based on the industry's very stringent QC specifications for column bleed, sensitivity, and efficiency, ensuring highly reliable qualitative and quantitative results. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 8 CB for PCB"

Ideal for ECD detection of trace PCBs! Excellent high-temperature stability ensures low bleed and ultra-long lifespan!

The "CP-Sil 8 CB for PCB" is a column that excels in high-temperature stability and is capable of continuous splitless injection. Due to the absence of cyano groups, it allows for ECD detection with a high S/N ratio. It is suitable for the ECD detection of trace amounts of PCBs and offers excellent high-temperature stability, resulting in low bleed and ultra-long life. 【Features】 ■ Excellent high-temperature stability, capable of continuous splitless injection ■ Designed for the analysis of PCBs based on the DIN method 51527 ■ Suitable for the ECD detection of trace PCBs ■ Excellent high-temperature stability leads to low bleed and ultra-long life ■ Subjected to testing based on the industry's very strict QC specifications for column bleed, sensitivity, and efficiency, ensuring highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-5.625"

Wide-ranging support for the analysis of basic, neutral, and acidic compounds! Cleaning with solvents is also possible.

The "DB-5.625" is a non-polar column of the chemical bonding type, enhanced in inertness and sensitivity through special processing. It is suitable as a standard column for the analysis of semi-volatile compounds using EPA methods 625, 1625, 8270, and CLP protocols. It features excellent thermal stability, a high temperature limit, and low bleed. Special testing has ensured performance that exceeds EPA performance standards for semi-volatile compounds. 【Features】 ■ Performance comparable to (5%-phenyl)-methylpolysiloxane ■ Non-polar ■ Performance exceeding EPA performance standards for semi-volatile compounds ■ Inert to basic, neutral, and acidic compounds ■ Excellent thermal stability, allowing for a high temperature limit and low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-5ms Semi-Volatile"

Demonstrates industry-leading sensitivity and consistency in the effective temperature range of -60 to 325/350℃!

The "HP-5ms Semi-Volatile" is a column that has been confirmed through testing to be inert to highly active compounds such as acidic and basic compounds. It demonstrates industry-leading sensitivity and consistency within an effective temperature range of -60 to 325/350°C. Testing is conducted based on Agilent's strict QC industry standards, and it features a chemical bond and cross-linking type, allowing for cleaning with solvents. 【Features】 ■ Has the same selectivity as HP-5 (5%-phenyl)-methylpolysiloxane ■ Non-polar ■ Ultra-low bleed suitable for GC/MS ■ Inertness to active compounds such as acidic and basic compounds confirmed through testing ■ Improved sensitivity and mass spectrum integrity due to excellent S/N ratio *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 5/C18 CB for PCB"

Designed for high-resolution analysis of PCBs! It has a C18 substituent and lower polarity than 100% polydimethylsiloxane.

The "CP-Sil 5/C18 CB for PCB" is a column with a C18 substituent that has lower polarity than 100% polydimethylsiloxane. Due to the absence of a cyano group, it allows for ECD detection with a high S/N ratio. With a 100m column, it can separate important isomer pairs 28/31, 56/60, 149/118, 105/153/132, and 170/190. 【Features】 ■ Designed for high-resolution analysis of PCBs ■ Has a C18 substituent and lower polarity than 100% polydimethylsiloxane ■ Allows for ECD detection with a high S/N ratio ■ Offers suitable column lengths for the separation of important isomer pairs 28/31, 56/60, 149/118, 105/153/132, and 170/190 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-Dioxin"

Separation of 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in a single analysis!

"DB-Dioxin" is a column designed for the analysis of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF). It is capable of separating 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in a single analysis. A 100 psi regulator is required to achieve the appropriate carrier gas flow rate. 【Features】 ■ Designed for the analysis of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) ■ Capable of separating 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in a single analysis ■ Low bleed ■ Chemical bonding and cross-linking type ■ Washable with solvent *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Select PAH"

Completely separate all PAH isomers! Provide accurate analysis results without false positives.

"Select PAH" is a capillary column that serves as a single solution for the analysis of polycyclic aromatic hydrocarbons (PAH). With excellent resolution for PAH isomers, it allows for the rapid, easy, and accurate quantification of PAHs in environmental and food samples. Since all isomers are separated in a single run, reliable analysis results without false positives can be obtained. 【Features】 ■ Completely separates all PAH isomers, providing accurate analysis results without false positives ■ Fully separates EPA-designated PAHs, including chrysene, triphenylene, and benzo(a)fluoranthene, in under 7 minutes, and EU-regulated PAHs in under 30 minutes ■ Provides rapid results in a single analysis ■ High sensitivity due to low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-EUPAH"

Designed for the analysis of PAHs regulated by the EU! Appropriate column dimensions to achieve reliable performance.

The "DB-EUPAH" column is optimized to achieve maximum performance in the analysis of all 16 types of polycyclic aromatic hydrocarbons (PAHs) regulated by the EU. Testing with application-specific QC test mixtures is conducted on all columns. It has very high thermal stability, allowing for accurate analysis of high-boiling PAHs such as dibenzopyrene. 【Features】 ■ Designed for the analysis of EU-regulated PAHs ■ Testing with application-specific QC test mixtures is conducted on all columns ■ Excellent resolution for important isomers such as benzo(b,j,k)fluoranthene ■ Very high thermal stability, allowing for accurate analysis of high-boiling PAHs such as dibenzopyrene ■ Excellent S/N ratio *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Select 624 CB"

Excellent column-to-column reproducibility! Highly reliable qualitative/quantitative results can be obtained.

The "CP-Select 624 CB" is a column that further enhances the reproducibility of the proven 624 stationary phase. Bleed is kept to 1/2 to 1/3 of that of typical columns (for a column with a length of 30m, an inner diameter of 0.53mm, and a film thickness of 3.00μm, the bleed specification is 9pA). With 6% cyanopropylphenyl and 94% dimethylpolysiloxane as the stationary phase, maximum inter-column reproducibility is ensured through rigorous synthesis based on strict standards and thorough characterization. 【Features】 ■ Reliable and precise separation of EPA-designated volatile compounds according to EPA methods 524.2, 624, and 8015. ■ Designated column for the pharmacopoeial method V.3.3.9 for residual solvent analysis, ensuring compliance. ■ Excellent inter-column reproducibility. ■ Low bleed. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Select 624 Hexane"

Since it undergoes testing based on QC specifications, highly reliable qualitative/quantitative results can be obtained!

The "CP-Select 624 Hexane" is a column designed for the separation of hexane isomers and dichloromethane, offering excellent reproducibility. Specialized QC tests for applications ensure appropriate resolution and inter-column reproducibility. Please feel free to contact us when you need assistance. 【Features】 ■ A stationary phase equivalent to USP G43 optimized for the separation of hexane isomers and dichloromethane ■ Separates acetonitrile and dichloromethane with a specified resolution of ≧1.0 according to USP <467> Residual Solvents ■ Excellent inter-column reproducibility ■ Undergoes testing based on very stringent industry QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results ■ Ensures the resolution of the CP-Select 624 Hexane column for separating dichloromethane from hexane isomers through application-specific QC tests *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-VOC"

Cleaning with solvent is possible, excellent peak shape! Highly reliable qualitative/quantitative results can be obtained!

The "HP-VOC" is a column precisely designed to exhibit excellent performance in the analysis of volatile organic compounds. The effective temperature range is -60 to 280/290°C, optimized for EPA Methods 502.2, 524.2, and 8260. This chemical bond/cross-linked type column provides high-quality peak shapes and can be used for applications requiring the analysis of purgeable or volatile organic compounds, volatile aromatic hydrocarbons, and unsaturated hydrocarbons. 【Features】 ■ Optimized selectivity for U.S. EPA Methods 502.2, 524.2, and 8260 ■ Low polarity ■ Excellent peak shape ■ Chemical bond/cross-linked type ■ Washable with solvent ■ Subjected to testing based on very stringent industry QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration