We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Column Product List and Ranking from 17 Manufacturers, Suppliers and Companies | IPROS GMS

Last Updated: Aggregation Period:Mar 04, 2026~Mar 31, 2026
This ranking is based on the number of page views on our site.

Column Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Mar 04, 2026~Mar 31, 2026
This ranking is based on the number of page views on our site.

  1. アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  2. 山善 Osaka//Machine elements and parts
  3. 東ソー バイオサイエンス事業部 計測分野 Tokyo//Chemical
  4. 4 null/null
  5. 4 日本ウォーターズ(米国本社 Waters Corporation)  Tokyo//Testing, Analysis and Measurement

Column Product ranking

Last Updated: Aggregation Period:Mar 04, 2026~Mar 31, 2026
This ranking is based on the number of page views on our site.

  1. GC column "DB-624" アジレント・テクノロジー株式会社
  2. GC column "DB-WAX" アジレント・テクノロジー株式会社
  3. Column "Inject Column" 山善
  4. 4 Column "CP-Volamine" アジレント・テクノロジー株式会社
  5. 5 GC column "DB-1" アジレント・テクノロジー株式会社

Column Product List

181~191 item / All 191 items

Displayed results

Column "PoraPLOT Q-HT"

The reproducibility of retention time is stable! Water elutes with a sharp peak, improving quantitative accuracy.

"PoraPLOT Q-HT" is a column for the analysis of volatile compounds. The maximum operating temperature has been expanded to 290°C. It can be used for applications involving halogenated compounds, hydrocarbons C1 to C6, organic solvents, and more. Please feel free to consult us when you need assistance. 【Features】 ■ Suitable for the analysis of a wide range of volatile compounds from high polarity to non-polar ■ Water elutes with sharp peaks, improving quantification accuracy ■ Stable reproducibility of retention times *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT Q"

Durable and recommended "Q" column! Good separation can be achieved in various applications.

"HP-PLOT Q" is a column made of bonded polystyrene-divinylbenzene. It can be used at a temperature limit of -60 to 270/290°C. Good separations are achieved in applications involving hydrocarbons, CO2, methane, air/CO, water, polar solvents, sulfur compounds, and more. It provides high separation in a shorter time compared to traditional packed columns. Please feel free to consult us when you need assistance. 【Features】 ■ Bonded polystyrene-divinylbenzene (DVB) column ■ A PLOT column with intermediate polarity between Porapak-Q and Porapak-N ■ A PLOT column that serves as an alternative to packed columns ■ High separation in a shorter time than traditional packed columns ■ Requires a minimum of 1 hour for conditioning *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-Q"

Separation of ethane, ethylene, and acetylene! Intermediate polarity PLOT column of Porapak-Q and Porapak-N.

The "GS-Q" is a column suitable for the analysis of gases containing fluorinated compounds and sulfur compounds. (Excluding SO2) It can be used within a temperature range of -60 to 250°C. The minimum conditioning time required is 1 hour, and it separates ethane, ethylene, and acetylene. Please feel free to contact us when you need assistance. 【Features】 ■ Porous divinylbenzene homopolymer ■ A PLOT column with intermediate polarity between Porapak-Q and Porapak-N ■ Separates ethane, ethylene, and acetylene ■ Not suitable for quantifying polar compounds ■ Minimum conditioning time: 1 hour *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT U"

It can be used in a wide range of applications such as CO2, methane, air/CO, water, solvents, alcohols, and ketones.

"HP-PLOT U" is a column with a stationary phase bonded with divinylbenzene/dimethacrylate ethylene glycol. It can be used in a wide range of applications including C1 to C7 hydrocarbons, CO2, methane, air/CO, water, dimethacrylate glycol-containing oxygen compounds, amines, solvents, alcohols, ketones, and aldehydes. Due to its high polarity, it has different selectivity and shows good peak shapes, especially for water-containing substances. 【Features】 ■ Bonded divinylbenzene/dimethacrylate ethylene glycol ■ Higher polarity than HP-PLOT Q ■ Suitable for C1 to C7 hydrocarbons, CO2, methane, air/CO, water, oxygen-containing compounds, amines, solvents, alcohols, ketones, and aldehydes ■ Provides high separation in a shorter time compared to traditional packed columns *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraPLOT U"

Prevent particle detachment as much as possible! Elute volatile compounds from high polarity to non-polar at symmetrical peaks.

"PoraPLOT U" is an analytical column for halogenated compounds, hydrocarbons, and ketones. It elutes high-polarity volatile compounds with well-symmetrical peaks. Water in the sample does not affect the retention time and does not cause broadening. Please feel free to consult us when needed. 【Features】 ■ Elutes volatile compounds from high polarity to non-polar with symmetrical peaks ■ Minimizes particle shedding *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-Alumina KCl"

Special deactivation! A versatile column suitable for the analysis of light hydrocarbons of C1 to C8 hydrocarbon isomers.

"GS-Alumina KCl" is a column that has undergone special inertization and can be rapidly regenerated. This product, which completely adsorbs water, can be regenerated at 200°C in less than 7 hours. It is also suitable for the separation of cyclopropane from propylene and is recommended as an alternative to sodium sulfide alumina due to its regenerability. 【Features】 ■ High polarity alumina phase ■ Special inertization ■ Faster, more efficient, and highly sensitive compared to equivalent packed columns ■ Minimal conditioning required ■ Recommended as an alternative to sodium sulfide alumina due to its regenerability *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT Al2O3 S"

Ideal for accurate quantitative analysis of diene! Separating propadiene and butadiene from the flow of ethylene and propylene.

The "HP-PLOT Al2O3 S" is a column that can separate gases at room temperature. It is suitable for KCI-treated inactive alumina. Different inert treatments have been applied to Al2O3, providing good resolution in hydrocarbon isomer analysis. We offer products with film thicknesses of 5.00, 8.00, and 15.00 μm. Please feel free to consult us when you need assistance. 【Features】 ■ Inactivated with KCl ■ Lower retention for olefins compared to corresponding paraffins ■ A standard column suitable for the analysis of lower hydrocarbons in C1 to C8 hydrocarbon isomers ■ Particularly suitable for accurate quantitative analysis of dienes, especially separating propyne and butadiene from the flow of ethylene and propylene *For more details, please refer to the PDF materials or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-Alumina"

High-speed, efficient, and highly sensitive! Suitable for the separation of propylene from cyclopropane.

"GS-Alumina" is a general-purpose column suitable for the analysis of light hydrocarbons in C1 to C8 hydrocarbon isomers. It is fast, efficient, and highly sensitive. Due to its regenerability, it is recommended as an alternative to sodium sulfide alumina. It is also suitable for the separation of propylene from cyclopropane. Please feel free to consult us when needed. 【Features】 ■ High polarity alumina phase ■ Special inertization ■ Fast, efficient, and highly sensitive ■ Separation of C1 to C4 saturated and unsaturated hydrocarbons ■ General-purpose column suitable for the analysis of light hydrocarbons in C1 to C8 hydrocarbon isomers *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-GasPro"

Separation of CO and CO2 in a single column! Suitable for the analysis of light hydrocarbons and sulfur gases.

The "GS-GasPro" is a column that can be used at temperature limits of -80 to 260/300°C. With its unique bonded silica PLOT column technology, it offers retention stability that is not affected by water. Agilent's commitment to reliability and reproducibility in its products supports the improvement of quality levels demanded by chromatography experts. Please feel free to consult us when needed. 【Features】 ■ Unique bonded silica PLOT column technology ■ Suitable for analysis of light hydrocarbons and sulfur gases ■ Retention stability unaffected by water ■ Separates CO and CO2 with a single column ■ Ideal PLOT column for GC/MS - does not generate particles *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-SilicaPLOT"

Separation of cyclopropane and propylene! Analysis of carbon dioxide and sulfur gas at ppm levels.

"CP-SilicaPLOT" is a column that provides high separation and fast analysis. It is ideal for the analysis of COS, CFC, hydrocarbons, propylene, and sulfur gases in ethylene. It can analyze carbon dioxide and sulfur gases at the ppm level and separate cyclopropane and propylene. Please feel free to contact us when you need assistance. 【Features】 ■ Retention time is unaffected by water ■ Analyzes carbon dioxide and sulfur gases at ppm levels ■ Separates cyclopropane and propylene *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CarboBOND"

No particle trap needed with chemical bonding type! Stability and robustness enhance the reproducibility of results.

"CarboBOND" is a column compliant with ASTM D 2505. It is suitable for the analysis of hydrocarbons in ethylene, gases in ethylene and propylene, He, Xe, CO, Ne, CH4, CO2, O2/Ar, N2, and Kr. High-boiling compounds can also be eluted in a short time, and since it is not affected by water, the reproducibility of retention times is excellent. 【Features】 ■ Column compliant with ASTM D 2505 ■ Maximum operating temperature extended to 300°C ■ Stability and robustness enhance the reproducibility of results ■ Chemical bond type, no particle trap required *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration