AC current sensor selectable in capacities from 60A to 630A.

A lineup of 60A, 125A, 250A, 400A, and 630A is available. You can select models based on the actual current of the target circuit, cable diameter, and conditions inside the panel.

When adding AC current sensors to existing equipment circuits or branch circuits, it is important to check not only the equipment name but also the actual current, cable diameter, panel space, power supply, and communication wiring. The PAL-Plus 60A measures AC currents up to 60A, while the high-capacity versions measure 125A, 250A, 400A, and 630A. The PAL series allows you to choose between simple power sensors or AC current sensors based on the data you want to verify, circuit configuration, and current capacity. 【Challenges】 - I want to select an AC current sensor that matches the circuit capacity. - I want to manage from small capacity to main circuits using the same method. - I want to determine the rating based on actual current and cable diameter. 【Benefits of Implementation】 - Selection by rating from 60A to 630A. - Compatibility from small capacity equipment to main circuits. - Consideration of configurations that match actual current and cable diameter. You can check detailed specifications and connection configurations in the downloadable materials. For more details, please download the materials or feel free to contact us.

  • Sensors
  • Other machine tools
  • Other processing machines
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

High Current Compatible CZ375x Series for Data Centers

High-current compatible sensors for optimizing power management in data centers.

In the data center industry, accurate monitoring and control of power supply is essential for the stable operation of servers and network equipment. In particular, with the increase in power consumption, efficient operation of power units is required. Improper power management can lead to equipment failure and system downtime. The CZ375x series accurately measures large currents and contributes to the optimization of power management. [Usage Scenarios] - Power monitoring for server racks - Current measurement for UPS (Uninterruptible Power Supply) - Visualization of power consumption [Benefits of Implementation] - Accurate understanding of power usage - Efficiency of power systems - Realization of stable operation of equipment Hakuto Co., Ltd., as a specialized electronics trading company, provides optimal products tailored to customer needs. We also offer technical support to assist in solving customer challenges.

  • Sensors
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Confirm the large-capacity circuits of the press process and centrally manage multiple circuits.

Supports processes with a mix of large-capacity and small-capacity circuits. Select sensors according to the actual current and cable diameter, allowing for centralized management of multiple circuits.

In die casting and pressing processes, there may be a mix of high-capacity main circuits and low-capacity peripheral circuits. Instead of using the same rated sensors for all circuits, it is necessary to select them according to the actual current and cable diameter. The PAL series, Gateway BOX, and CEW-M4 can be combined according to their purpose, allowing for a phased configuration from circuit-specific measurements to cloud verification and centralized management. 【Challenges】 - There is a mix of high-capacity and low-capacity circuits. - I want to view multiple circuits on the same screen. - I want to compare with production schedules and inspection records. 【Benefits of Implementation】 - Use different sensors according to circuit capacity. - Consolidate multiple circuits onto a common screen. - Understand usage trends across the entire process. You can check detailed specifications and connection configurations in the downloadable materials. For more information, please feel free to download the materials or contact us.

  • Power Monitoring Equipment
  • Other machine tools
  • Other processing machines
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【TI:INA2126UA/2K5】

【Support for Electronic Component Procurement】 We support the urgent procurement of discontinued (EOL) and hard-to-obtain electronic components and semiconductors! We have established a thorough inspection system.

Are you looking for this model number product? ■Manufacturer: TI ■Model number: INA2126UA/2K5 Owen Corporation quickly procures electronic components that have become difficult to obtain due to production discontinuation or delivery issues from a global network. We will definitely issue a quotation, so you can confirm the details before placing an order, ensuring peace of mind. A veteran inspector who has monitored market distribution inventory for over 20 years conducts inspections, and only products that pass are shipped. All delivered items come with an inspection report. 【Our Inspection System】 ■X-ray Inspection Non-destructive testing to check internal structures and detect counterfeit or inferior products. ■Microscope Careful examination of lead bending and any discrepancies in printed fonts. ■Digital Caliper Dimension measurements in 0.01mm increments to detect cleverly crafted counterfeits. ■Curve Tracer Displays voltage and current characteristic waveforms between terminals on the screen to detect defective products. ★Please visit our website from the link below. ★You can view our company brochure from the download button below. ▼For other model numbers you can inquire about, please refer to the lineup below.

  • others
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Visualize the large-capacity circuits of the molding line and compare them with operational records.

Measured using large-capacity circuits that supply power to equipment groups and auxiliary systems. You can compare records of production schedules, operating days, maintenance work, and current fluctuations.

In the molding line, in addition to the main equipment, high-capacity circuits that support the operation of the entire line are used. However, if only the main equipment is monitored, it is difficult to grasp the operational status and usage trends of the entire equipment, including the related circuits. The PAL-Plus High-Capacity version continuously measures the current of high-capacity circuits that supply power to equipment groups and auxiliary systems. By comparing records of production plans, operating days, and maintenance work with current data, it can be utilized to confirm the operational status of the entire line. Additionally, it supports high-capacity circuits ranging from 125A to 630A and can output measurement data to higher-level systems via Modbus RTU communication. 【Challenges】 Want to check the operational status of high-capacity circuits other than the main equipment. Want to keep a history of operations for each circuit supplying power to the equipment group. Want to compare records of production, operations, and maintenance work with current trends. 【Benefits of Implementation】 Records current data on a circuit-by-circuit basis for circuits supplying power to the equipment group. Allows comparison of records of operating days and maintenance work with current trends. Useful for understanding and analyzing the operational status of the entire line. For more details, please download the materials or feel free to contact us.

  • Ammeter
  • Sensors
  • Other processing machines
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

High current compatible compact/thin current sensor "CZ370x series"

Realizing the miniaturization of EV charging stations and the increase in output capacity! Coreless current sensor capable of detecting ±180A with surface mounting.

The CZ370x is a magnetic coreless current sensor that incorporates Hall elements. Due to the use of high-sensitivity Hall elements, it can measure a wide range of currents that typical coreless current sensors cannot achieve. It can handle continuous currents of up to 60Arms and accurately detect currents up to ±180A. Therefore, it contributes to "increased output capacity." Additionally, compared to shunt resistors and core-type through-hole sensors, it can contribute to "miniaturization" and "reduction of manufacturing costs." ■ Miniaturization - Due to its small size and surface-mount package, it can be mounted on the back side of the circuit board. - The primary conductor has low resistance (0.27mΩ), which suppresses heat generation and allows placement in limited space on the circuit board. * It generates only 1/4 the heat of a shunt resistor (based on our comparative test data). ■ Reduction of manufacturing costs It can contribute to reduced manufacturing (assembly) costs by eliminating the need for wire connections to through holes. * For more details, please refer to the PDF document or feel free to contact us.

  • Sensors
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【TI:INA226AIDGSR】

【Support for Electronic Component Procurement】We support the urgent procurement of discontinued products (EOL products) and hard-to-obtain electronic components and semiconductors! We have established a thorough inspection system.

Are you looking for this model number product? ■Manufacturer: TI ■Model number: INA226AIDGSR Owen Corporation swiftly procures electronic components that have become difficult to obtain due to production discontinuation or delivery issues from a global network. We will definitely issue a quotation, so you can confirm the details before placing an order, ensuring peace of mind. A veteran inspector who has been monitoring market distribution inventory for over 20 years conducts inspections, and only products that pass are shipped. All delivered items will include an inspection report. 【Our Inspection System】 ■X-ray Inspection Non-destructive testing to check internal structures and detect counterfeit or inferior products. ■Microscope Carefully checks for lead bending and any discrepancies in printed fonts. ■Digital Caliper Measures dimensions with an accuracy of 0.01 mm to detect cleverly crafted counterfeits. ■Curve Tracer Displays the voltage and current characteristic waveforms between terminals on the screen to detect defective products. ★Please visit our website from the link below. ★You can view our company brochure from the download button below. ▼For other model numbers you can inquire about, please refer to the lineup below.

  • others
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

PAL-Plus High-Capacity AC Current Sensor for Communications Equipment

Retrofit Current Monitoring to Existing Panels, PDUs, and Bus-Duct Branches

PAL-Plus High-Capacity is a split-core AC current sensor with integrated measurement and communications functions. It can be retrofitted to existing power and distribution panels to capture current on high-capacity circuits such as PDU secondary circuits and bus-duct branches. Use cases • Main and branch circuits in existing power/distribution panels • PDU secondary circuits and bus-duct branches • Feeder circuits by rack row or equipment area • Adding monitoring points during equipment upgrades Business benefits • Add monitoring while retaining existing equipment • Retrofit-friendly split-core design • Convert current values into data for remote monitoring • Scale from small deployments to multi-point systems

  • Ammeter
  • LAN construction and wiring work
  • UPS/Uninterruptible Power Supply
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Retrofit split clamp-type Modbus-compatible AC current sensor for existing panels.

Retrofitting current monitoring to existing systems. We support the visualization of current data while considering the burden of facility renovations.

When adding current monitoring to existing distribution boards and power equipment, devices that can be installed according to the available space inside the panel and wiring conditions while maintaining the operation of the equipment are required. The PAL-Plus high-capacity version is a split clamp-type AC current sensor that can be installed by sandwiching it between existing wiring, allowing for installation on existing equipment without the need for power outage work. Additionally, it has built-in measurement functions and Modbus RTU (RS-485) communication capabilities, which reduces the number of devices and achieves a space-saving monitoring configuration. It is available in four models: 125A, 250A, 400A, and 630A, allowing selection based on the current values to be measured and cable diameters. 【Usage Scenarios】 - Adding current monitoring to existing equipment - Increasing monitoring points within the distribution board - Integration with existing upper-level systems 【Benefits of Implementation】 - Easy to install on existing wiring due to its split design - Reduction in the number of devices due to integrated measurement and communication - Effective use of limited space inside the panel - Transmission of current values to upper-level devices compatible with Modbus *For more details, please refer to the PDF document or feel free to contact us.

  • Ammeter
  • Server monitoring and network management tools
  • UPS/Uninterruptible Power Supply
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

PAL-Plus High-Capacity Current Sensor for Telecommunications Facilities

Modbus-Enabled Remote Monitoring for Power Panels, UPS Systems, and HVAC Loads

Communications buildings and telecom equipment rooms depend on stable operation of power panels, UPS systems, rectifiers, and cooling equipment. PAL-Plus High-Capacity is a retrofit-friendly split-core AC current sensor that outputs measured current via Modbus RTU for integration with existing monitoring systems and gateways. Use cases • Power and distribution panels in communications facilities • UPS secondary and rectifier circuits • HVAC/cooling and auxiliary equipment • Aggregating current data across multiple sites Business benefits • Remote visibility into supporting power infrastructure • Phased deployment from priority points • Easy integration using Modbus • Load-trend data for maintenance decisions

  • Ammeter
  • UPS/Uninterruptible Power Supply
  • LAN construction and wiring work
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

クランプ式で安全・簡単|PALシリーズセンサーの取付方法

後付け可能な「分割クランプ式センサー」で運用中の設備を止めることなく安全かつ簡単にセンサーを取り付けられます

Modbus RTU通信を採用したお手軽かつ、省スペースで交流電流を計測できる、 通信機能内蔵のIoTセンサー「PAL-Plus」「PAL-Plus大容量版」の取付方法をご紹介します! 【取付方法】 1. 交流電流を計測したい電線にセンサーをクランプします 2. 結束バンドで電線とセンサーをしっかり固定します 3. 完了 ※通電中の作業は、感電の恐れがありますのでご注意ください。

  • Ammeter
  • Power Monitoring Equipment
  • Demand Monitoring
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Early detection of equipment anomalies with AC current sensors for factories.

Visualize the power of the equipment and detect anomalies. Easily implementable in existing equipment with Modbus compatibility.

In factory equipment management, early detection of equipment anomalies is essential for maintaining productivity and ensuring safety. Equipment failures can lead to production line stoppages and unexpected cost increases. Our AC current sensors continuously monitor the current values of equipment and detect abnormal power consumption, helping to identify equipment anomalies early and minimize downtime. 【Usage Scenarios】 * Monitoring the current of equipment such as motors and pumps * Understanding the overall power usage of the production line * Reducing maintenance costs through anomaly detection 【Benefits of Implementation】 * Reducing the risk of equipment failure * Preventing losses due to unexpected production stoppages * Optimizing energy consumption

  • Power meter
  • Power Monitoring Equipment
  • Demand Monitoring
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

PAL-Plus High-Capacity Current Sensor for Data Center Distribution Panels

Retrofit Current Monitoring into Distribution Panels, PDUs, and PDPs

Adding current monitoring to rack distribution units such as PDUs and PDPs requires consideration of circuit count, limited panel space, wiring effort, and host-system integration. PAL-Plus High-Capacity integrates measurement and communications in each sensor. Connector and bus-cable architecture simplifies multi-point installations and retrofits. Use cases • Main and branch circuits in rack distribution panels • PDU/PDP primary and secondary circuits • New and existing distribution panels Business benefits • Add value to panels with current monitoring • Simple retrofit architecture • Reduced installation workload • Easy Modbus integration with upper-level systems

  • Ammeter
  • UPS/Uninterruptible Power Supply
  • LAN construction and wiring work
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Continuously measure the injection molding process circuit and compare it with the production history.

Added measurement points to the target circuit of the injection molding process. You can compare production plans, molding conditions, product changes, equipment usage records, and measurement history over a certain period.

In injection molding processes, there may be differences in the planned use of molding equipment and surrounding circuits. Relying solely on checks during patrols can make it difficult to keep a record of the transitions by circuit over a certain period. The PAL series, Gateway BOX, and CEW-M4 can be combined according to purpose, allowing for a phased configuration from circuit-specific measurements to cloud verification and centralized management. 【Challenges】 - I want to keep a history of the circuits in the injection molding process. - I want to compare it with molding conditions and production plans. - I need continuous data to supplement patrol inspections. 【Benefits of Implementation】 - Save the circuit history of the injection molding process. - Compare with production plans, molding conditions, and product changeovers. - Organize additional circuits and periods for verification. You can check the detailed specifications and connection configurations in the downloadable materials. For more details, please download the materials or feel free to contact us.

  • Sensors
  • Other processing machines
  • Other machine tools
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Visualizing the operating status of load equipment with current | Modbus sensor

Check the alternating current of the load equipment over time. This can be used as a basis for equipment maintenance decisions regarding operating conditions and load trends.

Load equipment may not be able to grasp changes in load solely from operational displays. The PAL series measures AC currents from 60A to 630A and outputs data via Modbus RTU. By combining it with monitoring software or PLCs, you can continuously check the operation and stop status, changes in load, and variations in operating time. 【Challenges】Unable to understand conditions outside of patrol times / Want to record load trends / Want to add measurement points to existing equipment 【Implementation Benefits】Collects current history for each piece of equipment, supporting the organization of inspection targets and comparisons before and after operational changes.

  • Ammeter
  • Power Monitoring Equipment
  • Demand Monitoring
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

電力の見える化 7つのポイント ※ポイント小冊子進呈中!

省スペース・コンパクト設計で、設置が簡単なセンサとゲートウェイBoxの活用に関する技術資料を進呈!

当資料では、ヘキサコア株式会社が提供するPALシリーズセンサー× ゲートウェイBOX活用方法や、「電力の見える化」7つのポイントに ついてご紹介しています。 小規模導入やトライアルに「すぐに」対応可能であることに加え、 サーバー・ネットワーク構築不要であること等を掲載しており、  電力の見える化に寄与する7つのポイントが記載されております。  【小冊子内容】 ■計測データを「すぐに」「手軽に」見える化&監視できるゲートウェイBOXのポイント ■交流電流・簡易積算電力量を計測できるPALシリーズセンサーのポイント ■主な取扱製品・会社概要 この他にも、「ゲートウェイBOX」や「PAL-Plus typeE」、「PAL-Plus」 などの主な取扱製品もラインアップ。ぜひ、ご一読ください。 ※詳しくはPDFをダウンロードしていただくか、お問い合わせください。

  • Sensors
  • Power Monitoring Equipment
  • Demand Monitoring
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

AC Current and Basic Power Measurement Sensor Compatible with Single-Phase 3-Wire and Three-Phase 3-Wire Systems (Rated Current: up to 630A)

The same series also includes the PAL-Plus Type E, offering a more cost-effective solution for simplified cumulative energy measurement. Learn more here.

PAL-Plus Type E2 is an IoT sensor with integrated communication capability, designed for simplified cumulative energy measurement. Four models are available, supporting rated currents of 125A, 250A, 400A, and 630A. Utilizing a two-CT measurement method, this Modbus-compatible sensor provides more accurate power monitoring even in environments with load imbalance. Key Features: Modbus RTU Protocol ensures high compatibility and easy integration with existing systems. Split-clamp design allows safe and simple installation without halting equipment operation. Ultra-compact design achieved by integrating communication functionality, enabling easy deployment even in sites with multiple measurement points. What is Simplified Measurement? Based on preset voltage and power factor values, the sensor calculates simplified cumulative energy and power from measured current values. It also outputs cumulative current values, providing consistent reference data for energy monitoring. Compatible with single-phase 3-wire and three-phase 3-wire systems. For more details about the product and simplified measurement, please feel free to contact us.

  • Power meter
  • Power Monitoring Equipment
  • Demand Monitoring
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Gradual implementation of visibility in the molding factory from critical circuits.

Select the configuration according to measurement items, circuit methods, current capacity, and management scale. It can be gradually expanded from partial introduction of important circuits to management of multiple lines.

In the visualization of the molding factory, it is necessary to organize the data to be confirmed, circuit type, current capacity, and target range, rather than applying the same sensors and management methods to all equipment. When checking alternating current, consider using PAL-Plus60A or a high-capacity version; for checking trends in simple power and simple cumulative power consumption, consider type E or type E2. The PAL series, Gateway BOX, and CEW-M4 can be combined according to the purpose, allowing for a phased configuration from circuit-specific measurements to cloud verification and centralized management. 【Challenges】 - I want to start visualization from important circuits. - I want to select equipment that matches the circuit type and capacity. - I want to gradually expand to multiple lines and locations. 【Benefits of Implementation】 - Partial implementation from important circuits. - Selection of equipment that matches the purpose, circuit, and capacity. - Gradual expansion to multiple lines and locations. You can check detailed specifications and connection configurations in the downloadable materials. For more details, please download the materials or feel free to contact us.

  • Sensors
  • Chiller
  • Injection Molding Machine
  • Current Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration