We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Mass spectrometer.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Mass spectrometer Product List and Ranking from 33 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

Mass spectrometer Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

  1. サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K. Tokyo//Testing, Analysis and Measurement
  2. 日本ウォーターズ(米国本社 Waters Corporation)  Tokyo//Testing, Analysis and Measurement
  3. 一般財団法人材料科学技術振興財団 MST Tokyo//Testing, Analysis and Measurement
  4. 4 アズサイエンス 松本本社 Nagano//Trading company/Wholesale
  5. 4 Kyoritsu Electric Corporation Shizuoka//Industrial Electrical Equipment

Mass spectrometer Product ranking

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

  1. Triple Quadrupole Mass Spectrometer (LC-MS/MS) サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K.
  2. Orbitrap Astral Mass Spectrometer サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K.
  3. [Case Study] Quantitative Analysis of Brighteners and Decomposition Products in Electrolytic Nickel Plating Solutions サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K.
  4. 4 HPLC and mass spectrometry for the analysis and testing of cosmetics and personal care products. 日本ウォーターズ(米国本社 Waters Corporation) 
  5. 4 Tandem Quadrupole Mass Spectrometer Xevo TQ Absolute 日本ウォーターズ(米国本社 Waters Corporation) 

Mass spectrometer Product List

151~160 item / All 160 items

Displayed results

Flight Time Mass Spectrometer (LC-Tof) ACQUITY RDa

A compact LC-MS that obtains precise mass information with minimal effort and allows for easy data analysis.

Mass spectrometers, particularly high-resolution mass spectrometers capable of obtaining precise mass measurements, have traditionally been perceived as complex to operate, requiring deep knowledge and experience to master. However, this product overturns that image, offering a new concept device that anyone, from beginners to experts, can operate easily. With just one click, automatic setup is completed. It features a self-diagnosis function and automation capabilities from data acquisition to result summarization. Analysis is automatically performed upon completion, and reports tailored to the user's objectives are sent immediately. Additionally, despite being a single ToF, it supports CID and can obtain fragment information. Keep this compact single ToF, which can be installed with a 100V power supply, close at hand to enhance the efficiency of your daily operations. **Features:** - Precise mass analysis for screening and structural analysis from low to high molecular weights. - Simple operation allows anyone to easily obtain desired results. - Compact and energy-efficient. - Equipped with numerous functions to support measurement tasks, including automatic setup and self-diagnosis. - DI compatible. - A wide range of dedicated automatic analysis applications for various applications.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

We will introduce Agilent's expertise in PFAS.

Agilent's Environmental Sample PFAS Analysis Resource Kit

Agilent has deep insights and extensive experience in PFAS analysis methods in water and environmental samples as a leader in the environmental analysis market for over 40 years. We support a comprehensive PFAS analysis workflow, from sample preparation to screening, quantification, and reporting.

  • Analytical Equipment and Devices
  • Soil testing
  • Water quality testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Analysis of odor components using GCMS analysis method.

It is an analytical method for separating and qualitatively and quantitatively analyzing optical isomers and cis-trans isomers.

The analysis of odor components is effective for evaluating the scent that characterizes a product and for identifying the causes of unpleasant odors. Many odor components exist as stereoisomers, and isomers can have completely different scents from each other. When distinguishing and analyzing stereoisomers, methods such as NMR may be used; however, this case will introduce an example using GC/MS. Chromatography allows for the clear separation and evaluation of target components from other components. Additionally, by using columns designed for isomer separation, it is possible to evaluate various stereoisomers that cannot be separated using general-purpose columns. Measurement method: GC/MS Product fields: Cosmetics, daily necessities, food, environment Analysis objectives: Composition evaluation, identification, product investigation For more details, please download the materials or contact us.

  • img_C0713_1.jpg
  • img_C0713_3.jpg
  • MST_FIG0001.png
  • MST_FIG0002.png
  • MST_FIG0003.png
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Gas Chromatograph - Time-of-Flight Mass Spectrometer

A method for separating components by analyzing volatile components and utilizing differences in gas adsorption or distribution coefficients with respect to the stationary phase.

The gas chromatography time-of-flight mass spectrometer (GC-TOF MS) allows for the acquisition of precise mass information by using a time-of-flight mass spectrometer to detect components separated by GC. Compared to the integer mass information obtained from a typical quadrupole mass spectrometer, the accuracy of qualitative analysis is improved. Additionally, it is equipped with various ionization methods; the hard ionization method, EI, provides partial structural information, while the soft ionization method, FI, yields molecular weight information. By combining different ionization methods, the range of analytes that can be qualitatively analyzed is expanded. Furthermore, it is also possible to directly introduce samples into the ionization chamber, allowing for the evaluation of samples that are difficult to introduce via GC, such as thermally unstable substances and non-volatile compounds.

  • Contract measurement
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Analysis Case] Identification and Quantitative Evaluation of Solvents and Additives in LIB Electrolytes

Qualitative and quantitative evaluation is possible from the sampling of the electrolyte.

The electrolyte of lithium-ion secondary batteries can be qualitatively and quantitatively analyzed using GC/MS. In the example below, ethylene carbonate (EC) and ethyl methyl carbonate (EMC) were identified as organic solvents, and vinylene carbonate (VC) was identified as an additive. It is also possible to determine the composition ratio of the solvents and the content of the additives. Additionally, other additives such as fluoroethylene carbonate (FEC) and ethylene sulfite (ES) can also be evaluated.

  • c0259-2.jpg
  • c0259-3.jpg
  • C0259-4.jpg
  • Contract Analysis
  • Contract measurement

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Analysis Case] Composition Analysis of UV Curing Resin

The identification capability is enhanced when combined with soft ionization methods.

UV-curable resins harden quickly when exposed to ultraviolet light and are widely used as coating materials and adhesives due to their ease of use. In acrylate resins, which are commonly used materials, the molecular ions of acrylate monomers are difficult to detect using the conventional ionization method of EI in GC/MS analysis, leading to insufficient structural estimation. Here, we introduce a case where, in addition to the partial structural information obtained from the conventional EI method, the use of the soft ionization method FI enabled the detection of molecular ions, allowing for the estimation of the structure of acrylate monomers.

  • c0580-2.jpg
  • c0580-3.jpg
  • Contract Analysis
  • Contract measurement

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Search Keywords Related to Mass spectrometer