We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Syringe Filter.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Syringe Filter Product List and Ranking from 6 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Jul 16, 2025~Aug 12, 2025
This ranking is based on the number of page views on our site.

Syringe Filter Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Jul 16, 2025~Aug 12, 2025
This ranking is based on the number of page views on our site.

  1. null/null
  2. null/null
  3. トムシック Tokyo//Testing, Analysis and Measurement 本社
  4. 4 null/null
  5. 5 アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement

Syringe Filter Product ranking

Last Updated: Aggregation Period:Jul 16, 2025~Aug 12, 2025
This ranking is based on the number of page views on our site.

  1. DMSO Safe - Acrodisc Syringe Filter
  2. Acrodisc WBC syringe filter for the separation of white blood cells.
  3. Sterile Syringe Filter "BioPure" [Sample Available]
  4. 4 HPLC/IC PVDF Acrodisc Syringe Filter
  5. 4 0.45 μm PSF Acrodisc Syringe Filter

Syringe Filter Product List

16~29 item / All 29 items

Displayed results

Pre-treatment NYLON syringe filter

Introducing a suitable syringe filter for assays (analysis and evaluation) based on proteins and peptides from the Economical Series.

This product is a NYLON syringe filter with excellent solvent resistance and a hydrophilic membrane. It is suitable for protein and peptide-based assays (analysis and evaluation). Available in diameters of 13mm and 25mm, with pore sizes of 0.2μm and 0.45μm, and colors can be chosen from green and white, with a total of four types in the lineup. 【Features】 ■ Membrane: NYLON (hydrophilic) ■ Excellent solvent resistance with a hydrophilic membrane ■ Suitable for protein and peptide-based assays (analysis and evaluation) ■ Incompatible solvents: Acids > 1N, halogenated solvents, highly adsorptive protein-based samples *For more details, please refer to the PDF document or feel free to contact us.

  • Other filters

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pre-treatment PTFE syringe filter

Syringe filter for organic matrix with exceptional chemical resistance.

This product is a PTFE (hydrophobic) syringe filter with excellent solvent resistance due to its hydrophobic membrane. It is ideal for corrosive samples, acid solutions, and alkaline volumes, as well as organic matrices like hexane. The diameter sizes are 13mm and 25mm, with pore sizes of 0.2μm and 0.45μm, and color-coded (purple and orange) for easy identification of the filters. There are a total of four types in the lineup. 【Features】 ■ Membrane: PTFE (hydrophobic) ■ Excellent solvent resistance, usable with most organic solvents ■ Incompatible solvents: Perchloric acid, methylene chloride (△ can be used for short periods), dioxane, formic acid >50%, 100% aqueous samples (△ can be used if pre-filtered with alcohol) *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pre-treatment PTFE (hydrophilic) syringe filter

No need for hydrophilic treatment! All-rounder PTFE filter.

This product is a hydrophilic PTFE syringe filter that possesses the inherent chemical resistance of PTFE with a hydrophilic membrane. Traditionally, using hydrophobic PTFE syringe filters with aqueous solvents required pre-filtration with alcohol or similar substances. However, this hydrophilic PTFE filter eliminates the need for such pre-treatment processes and utilizes a groundbreaking PTFE membrane that can be used with aqueous solvents. Additionally, the excellent chemical resistance inherent to PTFE remains intact, allowing for use with both organic and aqueous solvents, which eliminates the need for different filters and contributes to cost reduction. The filter is available in diameters of 13mm and 25mm, with pore sizes of 0.2μm and 0.45μm, offering a total of four variations. 【Features】 ■ Membrane: PTFE (hydrophilic) ■ All-round filter with hydrophilic membrane and inherent solvent resistance of PTFE ■ Incompatible solvents: Chlorinated solvents such as chloroform and dichloromethane *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pre-treatment PES syringe filter

Hydrophilic with low protein adsorption. Economical series.

PES (Poly Ether Sulfone) is a syringe filter with high flow rate and hydrophilic membrane that exhibits low protein adsorption. It is suitable for the filtration of bacteria, viruses, and fungi. Available in diameters of 13mm and 25mm, with pore sizes of 0.2μm and 0.45μm, there are a total of four types in the lineup. 【Features】 ■ Membrane: PES (hydrophilic) ■ High flow rate with low protein adsorption due to hydrophilic membrane ■ Applications for bacteria, fungi, and viruses ■ Incompatible solvents: High concentrations of acids, methylene chloride, chloroform, hexane, acetone, MEK, THF, DMSO

  • Other laboratory equipment and containers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pre-treatment PVDF syringe filter

Increased recovery rate of adsorptive proteins due to low protein adsorption and broad chemical resistance.

This product is a PVDF syringe filter with a hydrophilic membrane that has extremely low protein adsorption. It is resistant to a wide range of organic solvents and is suitable for biological applications involving highly adsorptive proteins, peptides, etc. There are four types available, with diameters of 13mm and 25mm, and pore sizes of 0.2μm and 0.45μm. 【Features】 ■ Membrane: PVDF (hydrophilic) ■ Excellent solvent resistance with a hydrophilic membrane ■ Ultra-low adsorption for biological applications involving proteins, peptides, etc. ■ Incompatible solvents: DMF, DMSO, MEK, acetone, and most alkaline solvents *For more details, please refer to the PDF document or feel free to contact us.

  • Other laboratory equipment and containers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Captiva Premium Syringe Filter

Sample filtration prior to HPLC, UHPLC, LC/MS, GC, and GC/MS analysis is essential for achieving optimal system performance.

Sample filtration prior to HPLC, UHPLC, LC/MS, GC, and GC/MS analysis is essential to achieve optimal system performance. The Agilent Captiva Premium Syringe Filters accelerate this process more than ever, thanks to industry-leading flow rates and loading capacity. Additionally, Agilent conducts more LC/MS tests with syringe filters than other manufacturers to ensure that there are no extracts from the filters. All Agilent Captiva Premium Syringe Filters come with HPLC or LC/MS certification. You can choose from a variety of membrane types and pore sizes to suit your needs. - Agilent Captiva Premium Syringe Filter Specifications/Price List/Details - Agilent Captiva Premium Syringe Filter Selection Guide - Premium Syringe Filter Chemical Compatibility Chart - Instructions for Use - Captiva Syringe Filter *For more details, please refer to the PDF materials or feel free to contact us.

  • Other filters

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration