We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Tesla Meter.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Tesla Meter Product List and Ranking from 28 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

Tesla Meter Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

  1. エコー電子 Saitama//Industrial Electrical Equipment
  2. メステック Saitama//Testing, Analysis and Measurement
  3. 日本電磁測器 Tokyo//Industrial Electrical Equipment
  4. 4 マグネテックジャパン 本社 Saitama//Industrial Machinery
  5. 5 大栄無線電機 Tokyo//Trading company/Wholesale

Tesla Meter Product ranking

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

  1. Piezo Driver M-2691 メステック
  2. Handheld Tesla Meter "TM55" マグネテックジャパン 本社
  3. Magnetic flux density meter Tesla meter (Gauss meter) GV-400 日本電磁測器
  4. 4 Piezo driver キーストンインターナショナル
  5. 4 Tesla meter (magnetic flux density meter) SANKO ELECTRONIC LABORATORY CO.,LTD.

Tesla Meter Product List

31~45 item / All 117 items

Displayed results

Tesla Meter / Part Number MG14T-912M

Advanced handheld Tesla meter

■Dedicated measurement probe Can be replaced without troublesome adjustments. Tip dimensions (T) 1.0 × (W) 35 × (L) 65 ■External output, external power supply ■Measurement of surface magnetic flux density: Place the probe perpendicular to the magnetic field lines. ■Measurement of spatial magnetic flux density: Insert the probe perpendicular to the magnetic field lines. ■Incorrect usage: If the probe is placed parallel to the magnetic field lines, accurate measurements cannot be obtained.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Digital Tesla Meter / Model Number M784MZ-413T

● There is a high-resolution mode for measuring DC magnetic flux density. ● The frequency response range for measuring AC magnetic flux density is broad, from 40 to 500 Hz.

● It can be powered by both dry batteries and an AC adapter. ■ Introduction This manual explains the handling precautions and usage of the Tesla meter for operators. It contains important information that should be followed to prevent harm to customers and others, as well as damage to property, ensuring the safe use of this product. Any malfunctions or troubles arising from improper handling of this product are not covered by the manufacturer's warranty. Thank you for your understanding. ■ Product Overview ● It is compact, lightweight, and easy to operate, with a large digital display that is easy to read, making it suitable for use in many locations. ● It offers two measurement ranges: 0.0 to 200.0 mT and 0 to 2000 mT, allowing for high-precision measurements across a wide range, including high magnetic field measurements. ● The power supply can use a 006P type stacked dry battery (DC9V) or the included AC100V adapter. ● The peak hold function makes it easy to measure maximum values. ● It can measure both DC magnetic flux density and AC magnetic flux density. ● Probes can be replaced without calibration. ● The auto power-off function helps prevent unnecessary battery drain.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Tesla Meter / Part Number M504M-1012K

Food, pharmaceuticals, molds, precision machining... Active in managing magnetic flux density of de-iron magnets and measuring residual magnetism of workpieces, contributing to HACCP and ISO measures.

Food, pharmaceuticals, molds, precision machining... Active in managing magnetic flux density of de-iron magnets and measuring residual magnetism of workpieces! For HACCP and ISO compliance! We also provide free software that allows for recording magnetic measurement values. Suitable for inspection and verification of de-iron magnet rods in food processing, as well as measuring residual magnetism in electronic components, accommodating various inspection and measurement scenarios!

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Piezo Driver M-2629 Series

Maximum number of channels: 6ch

Input is 2 systems/channels - A input: non-inverting input (with respect to output) - B input: inverting input (with respect to output)

  • Other process controls

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Piezo Driver M-26123-1

Low cost, compact, low noise, energy-saving

Compact: Small and vertical type. It can be installed even on narrow tabletops. Low Cost: Achieves approximately 25% cost reduction compared to conventional products. Low Noise: Generates less heat, resulting in very low noise without the use of a cooling fan. Energy Saving: Consumes less than half the current compared to conventional products, reducing running costs. Safe Design: Equipped with a "Slow ON/OFF function" that protects the piezo element during output ON/OFF.

  • Other process controls

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Smart Tesla Meter "SMT-2000"

Your "PC" and "tablet" will transform into a high-performance Tesla meter.

The "SMT-2000" is a smart Tesla meter that achieves ultra-high precision through software-defined technology. Equipped with an inspection mode, it is convenient for magnet acceptance testing, magnetization testing, and quality control. In addition to OK/NG judgment functionality, it allows for one-click data recording and listing. It also features an external trigger, enabling the construction of an inspection device with just this one unit. Furthermore, connection is as simple as plugging a single USB cable into a PC. Its minimal size allows for a "smart" installation. 【Features】 ■ Ultra-high performance with a reading accuracy of ±0.2%  ※1 Sampling rate of 10Hz, excluding digit error ■ Data recording mode included ■ Inspection mode included ■ Easy connection with only a USB cable *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Column] About the Types of Magnetic Measurements

For those who are new to magnetic measurements: Total magnetic flux measurement and magnetic flux density measurement are representative!

Let me introduce the types of magnetic measurements. The typical ones are "total magnetic flux measurement" and "magnetic flux density measurement." To put it in familiar terms, "the population of Japan = total magnetic flux" and "the population density of Tokyo = magnetic flux density." If you want to see the overall strength of the magnet, you would use total magnetic flux measurement (flux measurement), and if you want to see the strength at a specific point, you would use magnetic flux density measurement. [Overview] ■ Measurement of total magnetic flux (flux measurement) ■ Measurement of magnetic flux density *For detailed content of the column, you can view it through the related links. For more information, please feel free to contact us.

  • magnet

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Column] What Applications Are Used For? Magnetic Flux Density Measurement Edition

For those who are new to magnetic measurements: The uses of a Tesla meter (Gauss meter)!

Magnetic flux density measurement is used for various applications, which I will introduce. "Magnetic flux density measurement" is used to determine the strength and direction of the magnetic field at a specific point, such as in the measurement of permanent magnets. Additionally, it is possible to understand the distribution of magnetic flux density using a magnet analyzer. 【Overview】 <Uses of Tesla meters (Gauss meters)> ■ Point-specific magnetic measurements - Types of magnetic probes that detect magnetic flux density ■ Distribution measurement of magnetic measurements *For detailed content of the column, please refer to the related links. For more information, feel free to contact us.

  • magnet

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Magnetic Measurement Products (Tesla Meter) Guide: SENIS

Magnetic fields can be measured as vectors! A wide variety of simple models suitable for experimental use are featured.

IMS Corporation is engaged in the sales, support, and customization of SENIS products, as well as the development, manufacturing, and sales of OEM products. In this guide, we introduce a variety of products, including the 3-axis Tesla meter "3MH3," the 3-axis analog magnetic field converter "F3A," and the 3-axis magnetic probe "TP-240." Additionally, we feature many advanced current sensors that apply sophisticated magnetic field measurement technology, known for their excellent linearity and insulation properties, so please feel free to download and take a look. [Featured Products (Excerpt)] ■ 3-axis Tesla Meter 3MH3 ■ 3-axis Analog Magnetic Field Converter F3A ■ 3-axis Magnetic Probe TP-240 ■ Magnet Analyzer MAPPER ■ Current Sensor CS-03 *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration