columnのメーカーや取扱い企業、製品情報、参考価格、ランキングをまとめています。
イプロスは、 製造業 BtoB における情報を集めた国内最大級の技術データベースサイトです。

column×アジレント・テクノロジー株式会社 - メーカー・企業と製品の一覧

columnの製品一覧

61~75 件を表示 / 全 157 件

表示件数

Column "DB-TPH"

Temperature range of -10 to 320°C! Introducing high-speed analysis columns with chemical bonding and cross-linking types!

The column "DB-TPH" handled by our company is designed for the analysis of total petroleum hydrocarbons (TPH), soil analysis, and the analysis of leaks (LUFT) from underground fuel tanks. It can perform three analyses (gasoline range organic compounds, diesel range organic compounds, motor oil) in a single injection. It allows for solvent cleaning and is compatible with a temperature range of -10 to 320°C. Additionally, high quality is ensured through extensive QC testing, demonstrating excellent performance in petroleum analysis applications. 【Features】 ■ Designed for the analysis of total petroleum hydrocarbons (TPH), soil analysis, and LUFT analysis ■ Capable of performing three analyses (gasoline range organic compounds, diesel range organic compounds, motor oil) in a single injection ■ High-speed analysis ■ Chemical bonding and cross-linking type ■ Solvent cleaning is possible *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Column "DB-FastFAME"

Corresponds to the requirements of AOAC, AOCS, and IOC regulatory methods! Chemical bonding, crosslinking type, solvent washable.

"DB-FastFAME" is a cyano-propyl phase designed for the high-speed and selective separation of both saturated and unsaturated fatty acid methyl esters (FAME). It also accommodates the separation of challenging cis-trans FAME isomers without compromising the separation capability obtained with conventional 100m columns. In less than 8 minutes, it can separate conventional FAMEs, including C18:1 and C18:2 cis/trans isomers, as well as common FAMEs such as DPA and EPA found in dairy fat, vegetable oils, and fish oils. 【Features】 ■ A cyano-propyl phase (G48) designed for the high-speed and selective separation of FAME ■ Ensures reproducibility of FAME equivalent chain length (ECL) values through individual testing with FAME mixtures ■ Complies with the requirements of AOAC, AOCS, and IOC regulatory methods ■ Chemically bonded, cross-linked type, solvent-washable ■ Intuvo specifications are also available *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Column "HP-88"

Maximum temperature 250/260℃! Designed for the separation of fatty acid methyl esters (FAME).

We would like to introduce the column "HP-88" that we handle. It is designed for the separation of fatty acid methyl esters (FAME) and is highly polar. It excels in the separation of cis/trans isomers compared to "DB-23" and is designed to withstand even higher temperatures while having nearly the same selectivity as "CP-Sil 88." 【Features】 ■ (88%-cyanopropyl) methylallyl polysiloxane ■ Upper limit temperature 250/260℃ ■ High polarity ■ Designed for the separation of cis/trans fatty acid methyl esters (FAMEs) ■ Even better separation of cis-trans isomers than "DB-23" *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Column "PoraBOND U"

Expand the maximum operating temperature! Improve data accuracy and detection limit with a low bleed type.

"PoraBOND U" is a chemical bond-type PLOT column that uses a high-polarity polymer as an adsorbent. The maximum operating temperature has been expanded from 190°C to 300°C. By keeping the bleed level low, the detection limit can be lowered, and the stabilization time of the column can also be shortened. Additionally, because it is a chemical bond-type column, it can be applied to analytical methods that require pressure changes. 【Features】 ■ Expanded maximum operating temperature ■ Low bleed type improves data accuracy and detection limits ■ Chemical bond type for long lifespan *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Column "PoraPLOT Q"

The reproducibility of retention time is stable! Water elutes at a sharp peak, improving quantification accuracy.

"PoraPLOT Q" is a column suitable for the analysis of a wide range of volatile compounds. This product can elute water with a sharp peak. It is capable of analyzing not only high-polarity volatile compounds but also non-polar hydrocarbons and permanent gases. Please feel free to consult us when you need assistance. 【Features】 ■ Applicable for the analysis of a wide range of volatile compounds from high polarity to non-polar ■ Elutes water with a sharp peak, improving quantification accuracy ■ Stable reproducibility of retention times *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Column "PoraPLOT S"

Good reproducibility! Volatile compounds from high polarity to non-polar eluted with symmetrical peaks.

"PoraPLOT S" is a column for the analysis of hydrocarbons and ketones. It uses divinylbenzene-vinylpyridine as an adsorbent. It is suitable for the analysis of moderately polar volatile compounds that require higher temperatures than the maximum usage temperature. Please feel free to consult us when you need assistance. 【Features】 ■ Elution of volatile compounds from high polarity to non-polar with symmetrical peaks ■ Minimization of particle shedding ■ Good reproducibility *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Column "HP-PLOT Al2O3 KCl"

Recommended for many ASTM methods! Suitable for KCI deactivated alumina.

The "HP-PLOT Al2O3 KCl" is a column that can separate gases at room temperature. It is suitable for the analysis of low molecular weight hydrocarbon isomers from C1 to C8. It has been treated with different inertization methods on Al2O3, providing good resolution in hydrocarbon isomer analysis. Please feel free to consult us when you need assistance. 【Features】 ■ Low polarity alumina phase ■ Inertized with KCl ■ Recommended for many ASTM methods ■ Suitable for alumina treated with KCl inertization ■ Lower retention of olefins compared to corresponding paraffins *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Column "CP-Al2O3/KCl"

High separation ability for hydrocarbons! Expands the scope of analysis with two polarities.

The "CP-Al2O3/KCl" is a column for the analysis of C1 to C5 hydrocarbons and impurities. It can analyze more compounds at once than packed columns, offers high separation capability, and allows for analysis in a shorter time. Compared to capillary columns using a liquid phase, it has higher selectivity and can separate C1 to C5 hydrocarbon isomers. 【Features】 ■ High separation capability for hydrocarbons ■ Short analysis time for hydrocarbons at temperatures above room temperature ■ Expands the range of analysis with two polarities *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Column "CP-Al2O3/Na2SO4"

High separation ability for hydrocarbons! A metal column that is resistant to physical shock.

The "CP-Al2O3/Na2SO4" is a column for the analysis of C1 to C5 hydrocarbons and impurities. It can analyze more compounds at once than packed columns, offering high separation capability and allowing for analysis in a shorter time. Compared to capillary columns using liquid phases, this product has high selectivity and can separate C1 to C5 hydrocarbon isomers. 【Features】 ■ High separation capability for hydrocarbons ■ Short analysis time for hydrocarbons at temperatures above room temperature ■ Expands analysis range with two polarities ■ Metal column resistant to physical shocks *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Column "HP-PLOT Al2O3 M"

Inactivated with KCl! Suitable for the analysis of lower hydrocarbons of C1 to C8 hydrocarbon isomers.

The "HP-PLOT Al2O3 M" is a column that can separate gases at room temperature. It is suitable for accurate quantitative analysis of dienes, particularly for separating propadiene and butadiene from the flow of ethylene and propylene. It has undergone different inertization treatments on Al2O3, providing good resolution in hydrocarbon isomer analysis. 【Features】 ■ Inertized with KCl ■ Low polarity alumina phase ■ Suitable for KCl inertized alumina ■ Recommended for many ASTM methods ■ Standard column suitable for low hydrocarbon analysis of C1 to C8 hydrocarbon isomers *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Column "GS-CarbonPLOT"

High stability, combined carbon layer stationary phase! Unique selectivity for inorganic and organic gases.

The "GS-CarbonPLOT" is a column with high stability and a bonded carbon layer stationary phase. The temperature limit has been extended to 360°C. It has retention stability that is not affected by water. Agilent's commitment to reliability and reproducibility in its products supports the improvement of quality levels demanded by chromatography experts. Please feel free to consult us when needed. 【Features】 ■ High stability, bonded carbon layer stationary phase ■ Unique selectivity for inorganic and organic gases ■ Temperature limit extended to 360°C ■ Suitable for GC/MS - does not generate particles ■ Retention stability that is not affected by water *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Column "CarboPLOT P7"

Analyzing carbon monoxide at ppmR levels! Stability and robustness to enhance the reproducibility of results.

The "CarboPLOT P7" is a column compliant with ASTM D 2505. It is suitable for the analysis of samples containing oxygen or air. It can separate nitrogen and carbon monoxide, demonstrating excellent performance for quantifying carbon monoxide at the ppm level. 【Features】 ■ Column compliant with ASTM D 2505 ■ Stability and robustness that enhance result reproducibility ■ Fast separation of carbon monoxide and carbon dioxide ■ Separation of oxygen and nitrogen ■ Analysis of carbon monoxide at the ppm level *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

ZORBAX RRHD column

A new level of sensitivity and separation capability! It aligns many binding phases and flexibly responds to various analyses.

The 'ZORBAX RRHD Column' we handle achieves true high-resolution analysis without compromising stability. Thanks to its excellent flexibility, it is possible to increase the flow rate to the column's limit without reducing separation efficiency or quality. With more than 12 types of bonded phases available, including HILIC, you can select the appropriate column according to your analytical needs. 【Features】 ■ Stability up to 1200 bar: Stable use with UHPLC equipment is possible. ■ Separation capability: Stable high-resolution analysis and scalability are achieved with 1.8 μm particles, making method conversion with 3.5 μm and 5 μm particles easy. ■ More reliable compound identification: High-resolution chromatograms and a column with an inner diameter of 2.1 mm enhance MS separation capability. ■ A wide range of selectable bonded phases: By combining ZORBAX and Poroshell 120 families, it becomes easier to accommodate various samples and facilitate method conversion. *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

HP-PLOT Molesieve Column

Durable 5Å molecular sieve coating! Introducing the PLOT column for permanent gas analysis.

The "HP-PLOT Molesieve Column" separates O2, N2, CO, and CH4 within 5 minutes. Agilent offers two types of molecular sieve PLOT columns with inner diameters of 0.53 mm and 0.32 mm. They can be used in various applications, including atmospheric monitoring. Additionally, it minimizes damage to baseline spikes and multi-port valves. 【Features】 ■ PLOT column for permanent gas analysis ■ Separates O2, N2, CO, and CH4 within 5 minutes ■ Minimizes damage to baseline spikes and multi-port valves ■ Alternative to GS-Molesieve ■ This product, which completely adsorbs water, can be regenerated at 200°C in less than 7 hours *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

PoraPLOT Amines Column

Efficient analysis under conditions above room temperature! Introducing Varian's unique PLOT column for amines.

"CP-PoraPLOT Amines" is a PLOT column uniquely developed for the analysis of highly volatile amines. It efficiently analyzes under conditions above room temperature and has high selectivity for volatile amines and ammonia. Please feel free to consult us when needed. 【Features】 ■ Guarantees the analysis of volatile amines ■ Efficient analysis under conditions above room temperature ■ High selectivity for volatile amines and ammonia *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録