1~8 item / All 8 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us OnlineBefore making an inquiry
Download PDF1~8 item / All 8 items
A compact near-infrared analysis device that completes the component analysis of all solutions with just one unit. - By adopting a special optical system, analysis is possible regardless of the size of light scattering with this one unit. - Economical due to the use of commercially available test tubes. - After spectral measurement, it can transition directly to chemical analysis. - Capable of non-destructive and rapid simultaneous analysis of multiple components. - Spectra can be acquired using a mobile device via Bluetooth connection.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will introduce various application examples of non-destructive component analysis devices using near-infrared spectroscopy. If you are having difficulties with data measurement or analysis tasks, please consult us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "USB Photo Mall" is a weak light measuring instrument that allows the transfer of photo mall control signals and measurement data using USB. It is equipped with a light sensor module that incorporates a high-sensitivity light sensor (photo mall) and signal processing circuitry. Weak light emission measurements can be performed with just one cable connection to a PC. 【Features】 ■ Measure and control weak light through the PC's USB port ■ Set sensitivity and measurement conditions via control signals ■ Output detection data (analog data) ■ Lightweight at 135g, compact housing *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "USB/RS232C Photon Counter" is a weak light measuring instrument that enables weak light measurement with just one cable connection to a PC. It connects the weak light measurement directly to the PC via USB or RS232C cable, transferring control signals and measurement data from the PC. 【Features】 ■ Measure and control weak light through the PC's USB or RS232C port ■ Built-in high-sensitivity light sensor (photomultiplier) and signal processing circuit ■ Set measurement time using control signals ■ Output detection data (count numbers) *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe S009 is a cell-insertion type ultra-wide range weak light measurement device. With a combination of a ND filter switching mechanism with a 3-digit attenuation rate and a photon counter, it can measure light intensity over a range of approximately 9 digits. It is mainly used for applications such as "nozzle carryover measurement," which verifies the cleaning effect inside the nozzle using enzyme-based chemiluminescent liquids. 【Features】 ■ Compatible with cells for spectrophotometers ■ Custom cells and round petri dishes can also be accommodated upon request *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe M018-01 is a near-infrared (NIR) analysis light source that can measure NIR absorption by irradiating the target with near-infrared light and analyzing the diffuse reflected light. By inputting the light output into a spectroscopic device, non-destructive component analysis based on near-infrared absorption becomes possible. 【Features】 ■ Effective for low reflectivity targets due to high-output lamps ■ Adjustable light output to match the measurement target ■ Achieves long lifespan and high stability through air cooling of the light source ■ Compact design with mounting holes for easy fixation to optical systems *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe M020-M023 is equipped with a near-infrared light source and measures the reflection and transmission components of the target object using a combination of FT-IR or FPI spectrometers for component analysis! It features a built-in high-output light source, enabling high-sensitivity measurements in the near-infrared range. The reflection type is equipped with an optical system that allows for dark field and diffuse reflection through dual-side illumination. The transmission type can perform transmission absorption measurements using a 10x10 cell. 【Features】 ■ Simple operation by just placing the measurement target on the light receiving window ■ Selection of FT-IR or FPI spectral modules based on the wavelength range *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe M011-02 is a component analyzer that non-destructively measures lipid components in fish and meat using near-infrared (NIR) light in the range of 640-1,050 nm. It can be connected to a PC or mobile device via wired (USB) or wireless (Bluetooth) methods, allowing for the acquisition of intensity information for each wavelength. The calculation of the target component is performed using the first and second derivatives of the absorbance changes at each wavelength. 【Features】 ■ Compact and lightweight due to ultra-small sensors ■ Wireless connectivity with mobile devices via Bluetooth ■ Acquired data is output in CSV format, making it easy to edit and analyze on a PC ■ Optional feature for creating calibration curves necessary for component analysis *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration