1~8 item / All 8 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online1~8 item / All 8 items
We have integrated the strainer and check valve into one unit. This leads to streamlined piping and a reduction in construction labor. Please use it for piping and mixing valves on the primary side where a standard check valve and strainer are required.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration<Operation when used as a mixing valve> ● Hot water from the H side and cold water from the C side are mixed, and the temperature is detected by a thermoelement, which moves the valve body via a piston (the movable part of the element). When the valve body moves, the opening degrees of the hot and cold water inlets are adjusted. Once the mixed water temperature reaches the set temperature, the mixing ratio stabilizes, and a constant temperature mixed water flows out from the M side. <Operation when used as a switching valve> ● The fluid temperature flowing in from the M side is detected by a thermoelement, which moves the valve body via a piston (the movable part of the element). When the valve body moves, the opening degrees of the H side and C side outlets are adjusted. The flow path is automatically switched to the discharge ports on the H side and C side based on the fluid temperature.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt is possible to arrange everything from plan creation to mold procurement, casting, machining, and plating.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Nippon Thermostat Co., Ltd., we have applied the temperature control technology cultivated in various fields, including automobiles, to residential equipment. We have developed a variety of thermal devices suitable for temperature control in water-related areas, such as "thermo faucets and mixing valves suitable for hot water supply in bathrooms and washbasins," "thermal actuators suitable for various air conditioning system applications that operate quietly and are suitable for fluid opening and closing," and "thermo ventilation openings suitable for air control as part of ventilation systems." Recently, our products have also been adopted as key components of the next-generation hot water supply system "EcoCute," which uses natural energy to produce hot water. 【Product Lineup】 ○ Thermo Cartridge ○ Thermal Actuator (2WAY・3WAY) ○ Thermo Ventilation Opening ○ Mixing Valve For more details, please contact us or download the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDuring normal use, it operates just like a regular faucet. When the surrounding temperature drops while in a shut-off state, the thermal element detects the temperature and automatically opens to drain the water. Additionally, when the temperature of the flowing water rises, it automatically closes. This process is repeated to prevent freezing.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe low-temperature operation valve protects water pipes from freezing during winter. When the temperature reaches a level where there is a risk of freezing, the thermoelement, which is the temperature control element, detects the ambient temperature, opens the low-temperature operation valve to drain the water, and allows warm water from underground to flow in, thereby preventing freezing. Additionally, the thermoelement detects when the temperature of the warm underground water eliminates the risk of freezing and automatically closes the valve. This product performs all of the above functions automatically and maintenance-free without the need for electricity.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn floor heating, it is used together with a thermal actuator to control the indoor temperature by switching the flow of hot water on and off. You can choose the temperature sensing method from "hot water," "room temperature," or "floor surface" types. Additionally, it only requires simple button operations without any complicated procedures. Furthermore, we also offer models with a timer function to meet customer needs.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFrom the perspective of hygiene, health, and energy conservation, hot water floor heating is currently attracting attention. The heating of the PTC heater causes the thermal element to expand and contract, opening and closing the valve. This controls the flow of hot water in an ON-OFF manner. Since the valve operates gently, it does not cause water hammer. There are also products that can be used with various air conditioning equipment and are compatible with different flow rates and circuit numbers.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration