Improvements in the three-wavelength method achieve ultimate high-resolution measurement. Infrared enables more precise moisture measurement. The IM-3SCV MODEL-1900 has been updated to the IM-3SCV MODEL-2000. Feature 1: Fiber method allows measurement in various environments - The use of fiber in the measurement section makes it less susceptible to atmospheric influences such as temperature changes in the measurement area. - It can be installed in a compact space even for measurements in narrow areas. - In locations with potential explosion hazards, the fiber separates the electrical systems, allowing for safe measurements. Feature 2: Real-time measurement with high-speed analog computation - By performing analog computation, there is almost no time lag, enabling real-time measurements while also allowing for high-resolution measurements. Feature 3: Stable measurement with the three-wavelength method - The three-wavelength method achieves high-resolution measurement. Feature 4: Handy type for easy portability - It is easy to carry, avoiding moisture absorption during sample transport, and allows for simple measurements on-site.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationImprovements in the three-wavelength method achieve ultimate high-resolution measurement. Infrared enables more precise moisture measurement. The IM-3SCV MODEL-1900 has been upgraded to the IM-3SCV MODEL-2000. Feature 1: Fiber method allows measurement in diverse environments - Using fiber in the measurement section minimizes the influence of environmental factors such as temperature changes in the measurement area. - It can be installed in compact spaces even for measurements in narrow areas. - In locations with potential explosion hazards, the fiber separates the electrical systems, allowing for safe measurements. Feature 2: Real-time measurement with high-speed analog computation - By performing analog computation, there is almost no time lag, enabling real-time measurements while also allowing for high-resolution measurements. Feature 3: Stable measurements with the three-wavelength method - The three-wavelength method achieves high-resolution measurement. Feature 4: Handy type for easy portability - It is easy to carry, avoiding moisture absorption during sample transport, and allows for simple measurements on-site.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFeatures of the HKT Series 〇 Low Measurement Pressure The minimum measurement pressure is 0.14N, which minimizes damage to the film and allows for accurate measurements. 〇 Selectable Resolution You can choose a model with the necessary resolution according to your application. 〇 Excellent Measurement Reproducibility An air release that maintains a constant descent speed of the measurement head reduces damage to the film and eliminates variability caused by the operator, allowing for accurate measurements of the film. 〇 Foot-Pedal Air Release Using a foot-pedal air release allows for stable measurements while holding the object with both hands. 〇 Optional Items Data can be transferred to a PC using dedicated software. It can also be changed to a hand pump.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFeatures of the HKT Series 〇 Low Measurement Pressure The minimum measurement pressure is 0.14N, making it difficult to damage the film and allowing for accurate measurements. 〇 Selectable Resolution You can choose a model with the necessary resolution according to your application. 〇 Excellent Measurement Reproducibility An air release that maintains a constant descent speed of the measurement head reduces damage to the film and eliminates variability caused by the operator, allowing for accurate measurements of the film. 〇 Foot-operated Air Release Using a foot-operated air release allows for stable measurements while holding the object with both hands. 〇 Optional Items Data can be transferred to a PC using dedicated software. It can also be changed to a hand pump.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFeatures of the HKT Series 〇 Low Measurement Pressure The minimum measurement pressure is 0.14N, which minimizes damage to the film and allows for accurate measurements. 〇 Selectable Resolution You can choose a model with the necessary resolution according to your application. 〇 Excellent Measurement Reproducibility An air release that maintains a constant descent speed of the measurement head reduces damage to the film and eliminates variability caused by the operator, allowing for accurate measurements of the film. 〇 Foot-operated Air Release Using a foot-operated air release allows for stable measurements while holding the object with both hands. 〇 Optional Items Data can be transferred to a PC using dedicated software. It can also be changed to a hand pump.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFeatures of the HKT Series 〇 Low Measurement Pressure The minimum measurement pressure is 0.14N, making it difficult to damage the film and allowing for accurate measurements. 〇 Selectable Resolution You can choose a model with the necessary resolution according to your application. 〇 Excellent Measurement Reproducibility An air release that maintains a constant descent speed of the measurement head reduces damage to the film and eliminates variability caused by the operator, allowing for accurate measurements of the film. 〇 Foot-operated Air Release Using a foot-operated air release allows you to hold the measurement object with both hands for stable measurements. 〇 Optional Items Data can be transferred to a PC using dedicated software. It can also be changed to a hand pump.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFeature 1: Detachable Structure of Optical Fiber - The detachable structure allows for easy handling during installation. It is secured by manually turning the bag nut. Feature 2: LCD Display with Touch Panel - Measurement values are displayed large on a 3.8-inch monochrome LCD. Easy operation with the touch panel. Feature 3: Compact and Lightweight - Compared to the conventional model (IM-3SCV), it is 70% smaller in volume and 50% lighter in weight. It has become easier to carry. Feature 4: Functions - It has functions for analog output (0-10V, 0-20mA), RS232C, cumulative averaging, and standard plate calibration.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWide-range and uneven surface moisture measurement is possible! 〇 Wide-range measurement accommodates a wider variety of themes. - With a maximum measurement diameter of 190mm, it enables over three times the wide-range measurement compared to fiber-type sensors. - Surface measurement of granular deposits such as pellets, capsules, and various raw materials is also possible. 〇 Stable measurement with a three-wavelength method. - The three-wavelength method achieves high-resolution measurement. 〇 Real-time measurement with high-speed analog computation. - By performing analog computation, there is almost no time lag, allowing for real-time measurement while also enabling high-resolution measurement unique to analog systems. 〇 Easy setup in any scene using universal parts. - By securing each angle to the frame at the bottom of the main unit, strong installation is possible in various scenarios such as hanging or elevating on a stand. - Installation locations are not limited, whether online or offline on conveyors, or on desks.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe new model is approximately 30% lighter than the old model (from 550g to 390g). Thickness measurement can be easily performed by simply sandwiching the object to be measured. The upper and lower holding rollers securely hold the object, minimizing tilt and variations in measurements caused by the operator, allowing for stable measurements. Additionally, the measuring probe can slide while being pressed by the holding rollers, enabling continuous measurements. It is capable of measuring various flat and sheet-like objects (up to 5mm thick). Main measurement targets include resin sheets, glass plates, metal plates, paper, carbon sheets, etc. (Please feel free to consult us about objects other than those listed above.)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Selectable resolution You can choose a model with the necessary resolution according to your application. - Excellent measurement reproducibility The air release allows for a constant descent speed of the measurement head, reducing damage to the film and eliminating variability caused by the operator. The thickness of the film can be measured accurately. - It is a stationary type, allowing for stable measurements. - It is a foot pump type, enabling measurement work to be done with both hands.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFeatures of the HKT Series 〇 Low Measurement Pressure The minimum measurement pressure is 0.14N, which minimizes damage to the film and allows for accurate measurements. 〇 Selectable Resolution You can choose a model with the necessary resolution according to your application. 〇 Excellent Measurement Reproducibility An air release that maintains a constant descent speed of the measurement head reduces damage to the film and eliminates variability caused by the operator, allowing for accurate measurements of the film.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt is easy to continuously measure thickness just by setting the film. Measurements can be taken with a resolution of 0.01μm. The measured data can be transferred to a PC or printed out. We can also customize specifications to match the measurement objects, so please feel free to consult us if you have any measurement concerns. We also offer free rental of demo units. We have newly released the FT-A300, which is a model change from the FT-A200. It is a high-precision measuring instrument with improved operability and enhanced stability. Additionally, there is a special type for thin films, the FT-A300HR. Options include a chart printer, PC, feeding rollers, and a winding device.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe ultimate high-resolution measurement has been achieved through improvements in the three-wavelength method. Infrared enables more precise moisture measurement. The IM-3SCV MODEL-1900 has been upgraded to the IM-3SCV MODEL-2000.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration