"CLE-110" is a device that non-invasively measures the concentration of cholesterol esters in human skin and assesses total cholesterol and LDL levels in the blood. Using the infrared ATR method, it can measure various concentrations without the need for blood sampling. With a combination of a high-performance infrared detector and a high-precision bandpass filter, measurement results can be obtained in a short time. 【Features】 - Easily measure cholesterol ester levels without blood sampling - No reagents or pre-treatment required - Compact tabletop design that saves space - Achieves rapid measurement - Measurement control and data processing are all controlled by a PC *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CLE-100" is a device that non-invasively measures the concentration of cholesterol esters in human skin and assesses total cholesterol and LDL levels in the blood. By simply placing your arm on the measurement section, you can easily determine the amount of cholesterol esters. It achieves short measurement times through a combination of a high-performance infrared detector and a high-precision bandpass filter. 【Features】 ■ Easily measure cholesterol ester levels without blood sampling ■ No reagents or preprocessing required ■ Compact tabletop design ■ Achieves short measurement times ■ Measurement control and data processing are all managed by a PC *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "HYBRID-3000E" is a fluorescence polarimetry measurement device capable of rapid and highly sensitive measurement of biomolecular interactions (with a new method for measuring optical rotation). It can measure with a small sample size (100μl). Both measurement control and data processing can be performed with a single PC. Measurement values can be graphed in real-time, and sigmoid curves can be viewed on the spot. 【Features】 ■ Rapid and highly sensitive measurement of biomolecular interactions ■ Works with a small sample size (100μl) ■ Measurement control and data processing can be done with a single PC *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "SCl System" is a concrete inspection device that measures the concentration of chloride ions in concrete structures exposed to salt damage environments. The "on-site measurement system" provides measurement results on the spot and allows for analysis using the spectral spectrum of the sample. It can control the device and process data using a mini notebook PC, and it can also be powered by a dedicated portable power supply in locations without AC power (100V). By employing a bright spectrometer, it obtains well-separated data with high resolution. 【Features】 ■ "On-site measurement system" that provides results on the spot ■ Analysis using the spectral spectrum of the sample ■ Device control and data processing can be done with a mini notebook PC ■ Compatible with a dedicated portable power supply ■ Utilizes a bright spectrometer *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "MPF-330" is a multiphoton excitation photolithography device that uses femtosecond lasers. By using ultra-short pulse laser light in the range of 750 to 900 nm as the excitation source, it enables two-photon excitation of materials that have absorption in the ultraviolet to visible range. It offers higher spatial resolution than conventional photolithography using high-power lasers, allowing for nanoscale photolithography. 【Features】 ■ Multiphoton excitation photolithography device using femtosecond lasers ■ Enables two-photon excitation of materials with absorption in the ultraviolet to visible range ■ Materials do not suffer thermal damage ■ Capable of three-dimensional processing only internally ■ Achieves processing resolution beyond the diffraction limit *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "EGR-100" is a compact micro-Raman measurement device. It is equipped with a vibration isolation mechanism and an electronic cooling CCD that can cool down to below -70°C, and it has a built-in high-performance compact 532nm green laser, ensuring safety through a mechanical interlock mechanism. This product offers high cost performance, providing Raman spectra equivalent to those obtained from large micro-Raman devices. 【Features】 ■ Compact, lightweight, low-cost, and high-performance ■ Micro system with vibration isolation mechanism ■ Bright optical system equipped with a compact spectrometer and high-performance electronic cooling CCD detector ■ High-performance compact green laser included (with mechanical interlock mechanism) ■ Horizontal laser light irradiation and polarization measurement compatible (optional) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe SCM-100 is a SiC microscopic observation device that has the function of applying a pre-programmed current to the built-in diode of a SiC sample's transistor. During current application, areas where no current flows (defects) do not emit light, allowing for the detection of defects by capturing images with a camera attached to the microscope. 【Features】 ■ Capture intervals from 3 seconds to 24 hours, with a maximum of 999 images that can be saved to an SD card ■ Output voltage, output current, and status information can be sampled at a maximum speed of 0.1 seconds ■ Control of 5 power supplies and data storage possible with a single PC ■ When output to a 17-inch LCD, the observation magnification is approximately 60x to 200x ■ Allows for real-time observation of defect growth in SiC samples *For more details, please download the PDF or feel free to contact us.