LSI - Company Ranking(17 companyies in total)
Last Updated: Aggregation Period:Aug 13, 2025〜Sep 09, 2025
This ranking is based on the number of page views on our site.
Display Company Information
Company Name | Featured Products | ||
---|---|---|---|
Product Image, Product Name, Price Range | overview | Application/Performance example | |
【Features】 ○ Motionnet(R) is a high-speed serial communication system. ○ Based on five types of devices developed independently by NPM, the "G9000 series." ○ A total wiring reduction system that can be operated remotely. → Input/output control required in the FA field. → Motor control. → CPU emulation leveraging high speed. → Message communication. ○ In cyclic communication for input/output control, the maximum time is 15.1μs. → Always transfers 4 bytes of data. → Communicates by interrupting with data such as motor control and LSI control data, up to 256 bytes (MAX). ○ Communication time can be calculated using a predetermined formula. → Guarantees real-time performance required in the FA field. 【Lineup】 ○ G9001A: Center device. ○ G9002: Local device (32-point I/O). ○ G9205: Local device (16-point I/O). ○ G9103C: Local device (pulse control). ○ G9004A: Local device (CPU emulation). ● For more details, please contact us or refer to the catalog. | For more details, please contact us or refer to the catalog. | ||
■ Linear interpolation is possible between any 2 to 4 axes. ■ Maximum output frequency: 15Mpps ■ Up/down counters: 2 built-in per axis (32 bits) ■ Comparators: 4 built-in per axis (32 bits) By utilizing the comparators and counters, the following operations are possible: - Interrupt output, external output of comparison results - Ring count function - Start using internal synchronization signals - Soft limit function ■ Speed and target position override are possible during operation - Rich variety of operation modes (10 types of operation modes available) - Manual pulse input terminal equipped (without multiplication & division functions) - Interrupt signals can be output for 11 types of error factors and 16 types of event factors (Event factors can be selected via registers) ■ Built-in pre-register (1 stage) for writing the next operation data (movement amount, speed, operation mode, etc.) during operation Since the data for the next operation can be pre-stocked, it is possible to smoothly transition to the next operation without stopping after the current operation is completed. | Optical instruments Medical devices Semiconductor manufacturing and inspection equipment Testing, analysis, and measurement instruments | ||
■ Supports the conventional 8-bit parallel bus and a new 4-wire serial bus When using the serial I/F, the parallel bus terminals can be utilized as general-purpose I/O terminals Up to 4 LSI devices can be connected in an expanded configuration with a single slave select signal ■ Maximum output frequency: 2.4Mpps ■ Supports linear/S-curve acceleration and deceleration ■ Built-in excitation sequence circuit for driving 2-phase stepping motors By adding stepping motor drive ICs or transistor arrays, a controller & driver system for stepping motors can be easily constructed ■ Simultaneous start/simultaneous stop function ■ Built-in current position counter (1 per axis) ■ Compact package (smallest in the industry for QFP type) ■ Operating temperature range: -40 to +85°C - Automatic slowdown point setting function - Idling pulse output function (1 to 7 pulses) - Speed override during operation is possible - Operating modes (4 types of operating modes available) | For more details, please contact us or refer to the catalog. | ||
---
--- |
--- |
-
- Featured Products
-
High-speed serial communication LSI G9000 series
- overview
- 【Features】 ○ Motionnet(R) is a high-speed serial communication system. ○ Based on five types of devices developed independently by NPM, the "G9000 series." ○ A total wiring reduction system that can be operated remotely. → Input/output control required in the FA field. → Motor control. → CPU emulation leveraging high speed. → Message communication. ○ In cyclic communication for input/output control, the maximum time is 15.1μs. → Always transfers 4 bytes of data. → Communicates by interrupting with data such as motor control and LSI control data, up to 256 bytes (MAX). ○ Communication time can be calculated using a predetermined formula. → Guarantees real-time performance required in the FA field. 【Lineup】 ○ G9001A: Center device. ○ G9002: Local device (32-point I/O). ○ G9205: Local device (16-point I/O). ○ G9103C: Local device (pulse control). ○ G9004A: Local device (CPU emulation). ● For more details, please contact us or refer to the catalog.
- Application/Performance example
- For more details, please contact us or refer to the catalog.
Pulse Control LSI PCL6100 Series
- overview
- ■ Linear interpolation is possible between any 2 to 4 axes. ■ Maximum output frequency: 15Mpps ■ Up/down counters: 2 built-in per axis (32 bits) ■ Comparators: 4 built-in per axis (32 bits) By utilizing the comparators and counters, the following operations are possible: - Interrupt output, external output of comparison results - Ring count function - Start using internal synchronization signals - Soft limit function ■ Speed and target position override are possible during operation - Rich variety of operation modes (10 types of operation modes available) - Manual pulse input terminal equipped (without multiplication & division functions) - Interrupt signals can be output for 11 types of error factors and 16 types of event factors (Event factors can be selected via registers) ■ Built-in pre-register (1 stage) for writing the next operation data (movement amount, speed, operation mode, etc.) during operation Since the data for the next operation can be pre-stocked, it is possible to smoothly transition to the next operation without stopping after the current operation is completed.
- Application/Performance example
- Optical instruments Medical devices Semiconductor manufacturing and inspection equipment Testing, analysis, and measurement instruments
Pulse Control LSI PCD4600 Series
- overview
- ■ Supports the conventional 8-bit parallel bus and a new 4-wire serial bus When using the serial I/F, the parallel bus terminals can be utilized as general-purpose I/O terminals Up to 4 LSI devices can be connected in an expanded configuration with a single slave select signal ■ Maximum output frequency: 2.4Mpps ■ Supports linear/S-curve acceleration and deceleration ■ Built-in excitation sequence circuit for driving 2-phase stepping motors By adding stepping motor drive ICs or transistor arrays, a controller & driver system for stepping motors can be easily constructed ■ Simultaneous start/simultaneous stop function ■ Built-in current position counter (1 per axis) ■ Compact package (smallest in the industry for QFP type) ■ Operating temperature range: -40 to +85°C - Automatic slowdown point setting function - Idling pulse output function (1 to 7 pulses) - Speed override during operation is possible - Operating modes (4 types of operating modes available)
- Application/Performance example
- For more details, please contact us or refer to the catalog.
-
Membership (free) is required to view all content.
Already a Member? Log In Here