We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for LSI.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

LSI - Company Ranking(17 companyies in total)

Last Updated: Aggregation Period:Aug 13, 2025〜Sep 09, 2025
This ranking is based on the number of page views on our site.

Company Name Featured Products
Product Image, Product Name, Price Range overview Application/Performance example
【Features】 ○ Motionnet(R) is a high-speed serial communication system. ○ Based on five types of devices developed independently by NPM, the "G9000 series." ○ A total wiring reduction system that can be operated remotely. → Input/output control required in the FA field. → Motor control. → CPU emulation leveraging high speed. → Message communication. ○ In cyclic communication for input/output control, the maximum time is 15.1μs. → Always transfers 4 bytes of data. → Communicates by interrupting with data such as motor control and LSI control data, up to 256 bytes (MAX). ○ Communication time can be calculated using a predetermined formula. → Guarantees real-time performance required in the FA field. 【Lineup】 ○ G9001A: Center device. ○ G9002: Local device (32-point I/O). ○ G9205: Local device (16-point I/O). ○ G9103C: Local device (pulse control). ○ G9004A: Local device (CPU emulation). ● For more details, please contact us or refer to the catalog. For more details, please contact us or refer to the catalog.
■ Linear interpolation is possible between any 2 to 4 axes. ■ Maximum output frequency: 15Mpps ■ Up/down counters: 2 built-in per axis (32 bits) ■ Comparators: 4 built-in per axis (32 bits) By utilizing the comparators and counters, the following operations are possible: - Interrupt output, external output of comparison results - Ring count function - Start using internal synchronization signals - Soft limit function ■ Speed and target position override are possible during operation - Rich variety of operation modes (10 types of operation modes available) - Manual pulse input terminal equipped (without multiplication & division functions) - Interrupt signals can be output for 11 types of error factors and 16 types of event factors (Event factors can be selected via registers) ■ Built-in pre-register (1 stage) for writing the next operation data (movement amount, speed, operation mode, etc.) during operation Since the data for the next operation can be pre-stocked, it is possible to smoothly transition to the next operation without stopping after the current operation is completed. Optical instruments Medical devices Semiconductor manufacturing and inspection equipment Testing, analysis, and measurement instruments
■ Supports the conventional 8-bit parallel bus and a new 4-wire serial bus When using the serial I/F, the parallel bus terminals can be utilized as general-purpose I/O terminals Up to 4 LSI devices can be connected in an expanded configuration with a single slave select signal ■ Maximum output frequency: 2.4Mpps ■ Supports linear/S-curve acceleration and deceleration ■ Built-in excitation sequence circuit for driving 2-phase stepping motors By adding stepping motor drive ICs or transistor arrays, a controller & driver system for stepping motors can be easily constructed ■ Simultaneous start/simultaneous stop function ■ Built-in current position counter (1 per axis) ■ Compact package (smallest in the industry for QFP type) ■ Operating temperature range: -40 to +85°C - Automatic slowdown point setting function - Idling pulse output function (1 to 7 pulses) - Speed override during operation is possible - Operating modes (4 types of operating modes available) For more details, please contact us or refer to the catalog.
---

---

---
  1. Featured Products
    High-speed serial communication LSI G9000 seriesHigh-speed serial communication LSI G9000 series
    overview
    【Features】 ○ Motionnet(R) is a high-speed serial communication system. ○ Based on five types of devices developed independently by NPM, the "G9000 series." ○ A total wiring reduction system that can be operated remotely. → Input/output control required in the FA field. → Motor control. → CPU emulation leveraging high speed. → Message communication. ○ In cyclic communication for input/output control, the maximum time is 15.1μs. → Always transfers 4 bytes of data. → Communicates by interrupting with data such as motor control and LSI control data, up to 256 bytes (MAX). ○ Communication time can be calculated using a predetermined formula. → Guarantees real-time performance required in the FA field. 【Lineup】 ○ G9001A: Center device. ○ G9002: Local device (32-point I/O). ○ G9205: Local device (16-point I/O). ○ G9103C: Local device (pulse control). ○ G9004A: Local device (CPU emulation). ● For more details, please contact us or refer to the catalog.
    Application/Performance example
    For more details, please contact us or refer to the catalog.
    Pulse Control LSI PCL6100 SeriesPulse Control LSI PCL6100 Series
    overview
    ■ Linear interpolation is possible between any 2 to 4 axes. ■ Maximum output frequency: 15Mpps ■ Up/down counters: 2 built-in per axis (32 bits) ■ Comparators: 4 built-in per axis (32 bits) By utilizing the comparators and counters, the following operations are possible: - Interrupt output, external output of comparison results - Ring count function - Start using internal synchronization signals - Soft limit function ■ Speed and target position override are possible during operation - Rich variety of operation modes (10 types of operation modes available) - Manual pulse input terminal equipped (without multiplication & division functions) - Interrupt signals can be output for 11 types of error factors and 16 types of event factors (Event factors can be selected via registers) ■ Built-in pre-register (1 stage) for writing the next operation data (movement amount, speed, operation mode, etc.) during operation Since the data for the next operation can be pre-stocked, it is possible to smoothly transition to the next operation without stopping after the current operation is completed.
    Application/Performance example
    Optical instruments Medical devices Semiconductor manufacturing and inspection equipment Testing, analysis, and measurement instruments
    Pulse Control LSI PCD4600 SeriesPulse Control LSI PCD4600 Series
    overview
    ■ Supports the conventional 8-bit parallel bus and a new 4-wire serial bus When using the serial I/F, the parallel bus terminals can be utilized as general-purpose I/O terminals Up to 4 LSI devices can be connected in an expanded configuration with a single slave select signal ■ Maximum output frequency: 2.4Mpps ■ Supports linear/S-curve acceleration and deceleration ■ Built-in excitation sequence circuit for driving 2-phase stepping motors By adding stepping motor drive ICs or transistor arrays, a controller & driver system for stepping motors can be easily constructed ■ Simultaneous start/simultaneous stop function ■ Built-in current position counter (1 per axis) ■ Compact package (smallest in the industry for QFP type) ■ Operating temperature range: -40 to +85°C - Automatic slowdown point setting function - Idling pulse output function (1 to 7 pulses) - Speed override during operation is possible - Operating modes (4 types of operating modes available)
    Application/Performance example
    For more details, please contact us or refer to the catalog.