List of Contract measurement products
- classification:Contract measurement
1021~1050 item / All 2059 items
For those who have isolators. Achieving high chemical resistance and workability. Low cost and short delivery times are also possible for glove box and isolator gloves.
- Work gloves
Notice of participation in 'INTERPHEX Week Tokyo' from May 20 (Wednesday) to May 22 (Friday), 2026.
Ito Corporation will be exhibiting at "INTERPHEX Week Tokyo" held at Makuhari Messe. This exhibition is the largest in Japan, showcasing a wide range of products and services related to the research and manufacturing of pharmaceuticals, cosmetics, and regenerative medicine from 25 countries and regions around the world. Pharmaceutical and cosmetic manufacturers, as well as regenerative medicine companies, will be attending from all over the globe. We will be showcasing "Gloves for Glove Boxes/Isolators" manufactured by Tron Power. We look forward to your visit.
Dynamic balance adjustment service
- Contract measurement
Attach strain gauges that are orthogonal to the center of the specimen, or uniaxial gauges at 0° and 90°, to measure longitudinal and transverse strain.
- Contract measurement
Measure the behavior changes during cooling [P (pressure) - V (volume) - T (temperature)] and use it as simulation data for flow analysis and mold design.
- Contract measurement
20mm vertical burning test (IEC 60695-11-10 Method B, ASTM D3801)
- Contract measurement
Horizontal combustion test (IEC 60695-11-10 Method A, ASTM D635)
- Contract measurement
Vertical Combustion Test for Thin Materials (ASTM D4804)
- Contract measurement
125mm vertical combustion test (IEC60695-11-20, ASTM D5048)
- Contract measurement
Horizontal combustion test of foamed materials (ISO 3582, JIS K6400-6, ASTM D4986)
- Contract measurement
The oil temperature is raised at a constant rate (120°C/h), and a specified bending stress is applied to the sample, with the temperature at which the specified deflection is reached being defined as ...
- Contract measurement
The temperature at which the penetration depth of a needle with a cross-sectional area of 1 mm² reaches 1 mm under a specified load, while the oil temperature is steadily increased in the oil, is refe...
- Contract measurement
It is represented as BPT when a φ5mm steel ball is pressed with a load of 20N for 1 hour in oil at the test temperature, resulting in a sample indentation depth of 0.209mm.
- Contract measurement
The temperature that causes destruction with a 50% probability during impact testing in low temperatures with methanol/dry ice is referred to as the embrittlement temperature.
- Contract measurement
The glass transition temperature of the resin, as well as measurements of viscosity during melting, thermosetting behavior, and steady-state flow viscosity, can be performed.
- Contract measurement
This is a method for measuring accurate thermal conductivity without performing absolute measurements of heat quantity, by simultaneously measuring a reference sample with known thermal conductivity.
- Contract measurement
Measure the electrical resistance using an insulation resistance meter between the circular electrodes, and determine the volume resistivity and surface resistivity from the electrode shape.
- Contract measurement
While the volume resistivity and surface resistivity reflect the shape factors of the test specimen, the insulation resistance is directly indicated by the resistance value (Ω) between the tapered pin...
- Contract measurement
It is a standard for conductive rubber, but it is applied to resistance measurement of conductive plastics.
- Contract measurement
Place four needle-shaped electrodes in a straight line on the sample, pass a constant current between the outer two probes, measure the potential difference that occurs between the inner two probes, a...
- Contract measurement
Using the mutual induction bridge method, the dielectric constant and dielectric loss tangent are determined from the capacitance and conductance of the measurement object at equilibrium.
- Contract measurement
Apply a commercial frequency voltage of 50Hz or 60Hz across the electrodes with the test specimen in between, and determine the voltage that causes the sample to break down.
- Contract measurement
An arc discharge is generated at a specified interval between two tungsten electrodes on the surface of the test specimen, and the time until the sample breaks and the arc discharge disappears is also...
- Contract measurement
Apply a voltage between the platinum electrodes and drip the electrolyte until tracking failure occurs. Evaluate at a voltage that does not cause failure with the specified number of drips.
- Contract measurement
Charge Decay Measurement Device STATIC HONESTMETER Type S-5109 (Manufactured by Shishido Electrostatic Co., Ltd.)
- Contract measurement
It is possible to evaluate the electrostatic properties of polymer materials.
- Contract measurement
Measurement of injection flow length using spiral flow.
- Contract measurement
If you need to measure thermal conductivity, leave it to us.
- Contract measurement
Check trends in the location and size of internal defects with CT scans! Introducing our quality assurance.
- Contract Inspection
- Contract Analysis
- Contract measurement
We will provide various validation services that meet different standards.
- Other clean room equipment and facilities
- Contract Inspection
- Contract measurement
Analyze the filter after resin circulation as needed! Supporting optimal operation for our customers.
- Analytical Equipment and Devices
- Contract measurement
- filter
We support your research and development and quality control through contracted measurements!
- Contract measurement