We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Chromatography.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Chromatography×メトロームジャパン - List of Manufacturers, Suppliers, Companies and Products

Chromatography Product List

31~42 item / All 42 items

Displayed results

Ion Chromatography Basics: Pre-treatment Edition [Technical Document]

"IC: Ion Chromatography" A must-read booklet that clearly explains the sample pretreatment for ion chromatography, including combustion methods.

[Technical Data] Ion Chromatography Basics: Pre-treatment Edition Table of Contents Pre-treatment for Ion Analysis 1.1 Purpose of Pre-treatment 1.2 Is Pre-treatment Necessary? 1.3 Influence of Coexisting Components 1.4 Is Pre-treatment for Ion Chromatography Special? Sample Dissolution and Extraction 2 Dissolution 3 Extraction 3.1 Unit Operations Used in Extraction 3.2 Extraction of Ions from Oil Samples by Liquid-Liquid Extraction Method 3.3 Extraction of Ions from Solid Residues by Ultrasonic Extraction Method 3.4 Extraction of Ions from Organic Samples by Organic Solvent Dissolution - Liquid-Liquid Extraction Method 3.5 Extraction of Ions from Food Samples 4 Dissolution by Combustion Method 5 Distillation Total of 20 pages (including cover)

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Basics of Ion Chromatography: Terminology Edition [Technical Document]

A beginner's guide booklet that clearly explains various terms used in ion chromatography.

Not only ion chromatography, but also terms used in chromatography in general are explained. It is recommended for beginners in ion chromatography.

  • 4470_550X550.jpg
  • Ion Chromatography
  • Analytical Equipment and Devices
  • Water quality testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Basic Ion Chromatography: Column Edition [Technical Document]

A beginner's technical booklet that clearly explains columns for ion chromatography.

It can also be used as training material for beginners conducting ion chromatography for the first time.

  • 948-940-930-EcoIC-6063.jpg
  • Other environmental analysis equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Bulk water quality management of seawater in shrimp farms using ion chromatography [Technical Document]

Automating water quality management by simultaneously measuring nitrite, nitrate, and phosphate in seawater from shrimp farms using ion chromatography.

The concentrations of nitrite, nitrate, and phosphate in the seawater of the shrimp farm were measured using an ion chromatograph with a conductivity detector and a UV/VIS detector after chemical suppression.

  • 948-6204-2.jpg
  • Analytical Equipment and Devices
  • Ion Chromatography
  • Biofeed for Fisheries

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Ion Chromatography Technical Document: Creating a Wide Range Calibration Curve in a Single Measurement

Introducing a technique for creating a calibration curve for ion chromatography that covers a wide concentration range in a single measurement.

In ion chromatography with a conductivity detector and suppressor, it is often the case that the calibration curve is not actually linear. Particularly when the calibration curve needs to cover a wide concentration range, applying multiple calibration curves for different concentration ranges can lead to more accurate measurement results. By using MagIC Net software, multiple calibration curves can be created in a single measurement. This means that the optimal calibration curve for all ions is applied, improving the accuracy of the measurement results. This method can be applied to environmental waters such as tap water, seawater, and rainwater.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Ion Chromatography Materials: Creating a wide-range calibration curve in a single measurement.

Introducing a technique for creating a calibration curve for ion chromatography that covers a wide concentration range in a single measurement.

In ion chromatography with a conductivity detector and suppressor, it is often the case that the calibration curve is not actually linear. Particularly when the calibration curve needs to cover a wide concentration range, applying multiple calibration curves for different concentration ranges results in more accurate measurement results. By using MagIC Net software, multiple calibration curves can be created in a single measurement. This means that the optimal calibration curve for all ions is applied, improving the accuracy of the measurement results. This method can be applied to environmental waters such as tap water, seawater, and rainwater.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Ion Chromatography Technical Document] Measurement of Five Anions in Human Urine

An application that measures five types of anions contained in human urine using ion chromatography.

Using dialysis technology for automatic sample pretreatment, measurement of chloride, nitrate, phosphate, sulfate, and oxalate in urine using anion exchange chromatography.

  • 940_858_3909_550X550.jpg
  • 930_858_withmale3702_550X550.jpg
  • 4470_550X550.jpg
  • Analytical Equipment and Devices
  • Ion Chromatography
  • Other physical property measurements and component analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Ion Chromatography Technical Document: Measurement of Chloride and Other Anions in Surfactant Solutions

Measurement of fluoride, glycolic acid, monochloroacetic acid, and chloride in surfactant solutions by ion chromatography.

Quantification of fluoride, glycolic acid, monochloroacetic acid, and chloride in surfactant solutions using ion chromatography.

  • 940_858_3909_550X550.jpg
  • 930_858_withmale3702_550X550.jpg
  • 4470_550X550.jpg
  • Analytical Equipment and Devices
  • Ion Chromatography
  • Other cleaning machines

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Analysis of PFAS using combustion ion chromatography system [Technical Document]

Analysis of perfluoroalkyl and polyfluoroalkyl substances (PFAS) using combustion ion chromatography system.

Adsorptive Organic Fluorine (AOF) is the sum value that covers a wide spectrum of organic fluorine. AOF analysis is an appropriate screening analytical method for PFAS in water. DIN 38409-59 conducts AOF analysis using combustion ion chromatography (CIC), which combines a pyrolysis device and an ion chromatograph – AOF analysis can be performed using Metrohm's combustion ion chromatography system.

  • 948-940-930-EcoIC-6063.jpg
  • Analytical Equipment and Devices
  • Ion Chromatography
  • Water quality testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Trace analysis of haloacetic acids, dalapon, and bromate in drinking water [Technical Document]

Trace analysis of carcinogenic substances such as haloacetic acids (HAA), dalapon, and bromate using ion chromatography.

We conducted the analysis by connecting the Metrohm ion chromatography (IC) to an Agilent triple quadrupole mass spectrometer (MS). This high-sensitivity method does not require sample extraction and can eliminate interferences from the eluent due to the Metrohm suppressor module. The matrix spike recovery rate for all target analytes at 1 μg/L was between 65% and 115%, and good results were obtained even with highly contaminated water samples.

  • 930-GIF-1.gif
  • Ion Chromatography
  • Food/beverage component analyzer
  • Water quality testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

24/7 unattended environmental monitoring ion chromatograph

A process analyzer capable of 24/7 unmanned environmental monitoring using ion chromatography for meteorology, volcanoes, uninhabited islands, factories, and polar regions.

2060 MARGA is a fully autonomous sampling and measurement system that can continuously measure water-soluble gases and aerosol components that directly affect air quality. The measurement results can be used in research to identify the structure of aerosols and to investigate how their concentration and composition change with diurnal and seasonal cycles.

  • 2060MARGA-4899.jpg
  • 2060MARGA-6279.jpg
  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Water Quality Management Test Using Ion Chromatography Graphs [Technical Document]

Trace analysis of harmful DBPs (chlorite and chlorate), bromate, and dichloroacetic acid/DCAA using ion chromatography.

The US EPA Method 300.1 (Parts A and B), ISO 10304-1, and ISO 10304-4 are conducted to ensure compliance when monitoring water quality contaminants that affect human health. In particular, disinfection by-products (DBPs) are associated with carcinogenicity and reproductive effects. EPA Method 300.1 Part A and ISO 10304-1 specify the requirements for quantitative analysis of major inorganic anions by ion chromatography.

  • 948-6204-2.jpg
  • Ion Chromatography
  • Water quality testing
  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Search Keywords Related to Chromatography