We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Concentration Meter.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Concentration Meter Product List and Ranking from 41 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

Concentration Meter Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

  1. null/null
  2. サニー・トレーディング Kanagawa//Machine elements and parts
  3. テクネ計測 Kanagawa//Testing, Analysis and Measurement
  4. 4 日本ベーカーヒューズ株式会社&ベーカーヒューズ・エナジージャパン株式会社  (旧)GEセンシング&インスペクション・テクノロジーズ株式会社 & GEエナジー・ジャパン株式会社 Tokyo//Testing, Analysis and Measurement
  5. 5 null/null

Concentration Meter Product ranking

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

  1. Online densitometer formula slurry concentration meter
  2. Exhaust Gas Hydrogen Chloride Concentration Meter HL-36NS
  3. Trace Oxygen Analyzer 3000TA-EU (manufactured by Teledyne Japan) ユナイテッド・アナライザーズ・ジャパン
  4. 4 Ultrasonic Concentration Meter 'Densiter MODEL SDM-5100'
  5. 5 SS Concentration Meter 'SSD-1610 Model / SSD-1620 Model' 東亜ディーケーケー 本社、営業所(札幌・仙台・千葉・名古屋・大阪・広島・四国・北九州)、事業所(狭山、東大和)

Concentration Meter Product List

496~510 item / All 586 items

Displayed results

Instran Online Nitrate Concentration Meter

Continuous measurement of nitrate concentration in water is possible!

Method - Ion Selective Electrode Reagent 1 is added before analysis to activate the electrode. After that, the first measurement is taken. Next, a small amount of a high-concentration nitrate solution is added, and a second mV measurement is performed to calculate the results. If an extraction solution is used, cleaning with an ammonia-based cleaning solution is necessary after analysis to prevent cross-contamination. Many probes are affected by interference from nitrite and chloride, but in this method, using the extraction solution at the beginning of the analysis completely removes the influence of these two ions. Therefore, the only ion affecting the measurement is the nitrate ion (NO₃⁻).

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Instran Online Nitrite Concentration Meter

Even at a concentration of 100 ppb, which is often considered the legal limit in drinking water, a significantly high absorbance can be obtained.

After adding the sample to the measurement cell, several reagents are added to adjust the solution conditions (such as pH and the atomic valence of elements). Subsequently, a blank measurement is performed to correct for the effects of temperature and turbidity. Then, the final reagent is added, which reacts with the solution to produce color and is measured at the appropriate wavelength. Thanks to the photometer used, results can be obtained with very high accuracy. This method is based on the reaction in which nitrous acid generated from nitrite ions undergoes a diazotization reaction with sulfanilamide, forming a vivid colored diazo dye.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Instran Online Copper Ion Concentration Meter

Continuous measurement of copper ion concentration in water is possible!

Method - Colorimetric Analysis After adding the sample to the measurement cell, several reagents are added to adjust the conditions of the solution (such as pH and oxidation state). Subsequently, a blank measurement is performed to correct for the effects of temperature and turbidity. Then, the final reagent is added, which reacts with the solution to produce a color that is measured at the appropriate wavelength. The photometer used allows for highly accurate measurement results. This method is based on the reduction of copper(II) to copper(I) in acidic solutions. The neocuproine reagent specifically reacts with cuprous ions (Cu⁺). If present, iron can also be reduced to iron(II) (Fe²⁺) and may react with neocuproine. This method is specific to copper, and the cuprous-neocuproine complex has a clear and relatively strong absorbance, allowing for the measurement of low concentrations of copper at the ppb level. The influence of iron can be removed with additional reagents.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Instran Online Low Concentration Iron Ion Concentration Meter

Continuous measurement of low concentrations of iron ions in water is possible!

Method - Colorimetric Analysis After the sample is introduced into the measurement cell, several reagents are added to adjust the solution conditions (such as pH and the valence of elements). Subsequently, a blank measurement is conducted to correct for the effects of temperature and turbidity. Then, the final reagent is added, which reacts with the solution to produce a color that is measured at the appropriate wavelength. Depending on the photometer used, the results are obtained with very high precision. Trivalent iron (Fe³⁺) is reduced to divalent iron (Fe²⁺) by hydroxylamine hydrochloride. The divalent iron ions react with ferrozine in a buffer solution adjusted to a pH range of 5 to 7, forming a pink complex. This method allows for the measurement of very low concentrations of iron. The reagents used are stable. If it is necessary to measure total iron, the stirring time can be extended to ensure that the iron is completely dissolved in an acidic medium.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Instran Online Sodium (Na) Concentration Meter

Continuous measurement of sodium concentration in water is possible!

Method - Ion Selective Electrode Analysis is performed using the Standard Known Addition method (SKA). This process involves two measurements. The difference between the two and the slope obtained during calibration are used to calculate the concentration. By using both measurement values, changes in the matrix sample are corrected, and the calculation of results is based on the relative mV difference rather than absolute values. This helps to avoid external interference. Measurement Principle The sample is adjusted to pH 8-11 using an Ion Strength Adjuster (ISA). After that, the first measurement is taken. Next, a small amount of high-concentration sodium solution is added. Finally, a second mV reading is taken, and the results are calculated. The advantage of this method is that the rapid response of the electrode allows for quick analysis. The main interfering cations are either absent or present in very small amounts. Furthermore, the ISA solution prevents these interferences. *Interfering factors: Lithium, Potassium, Rubidium, Ammonia, Silver, Thallium

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Application Example: Ultrasonic Gas Concentration Meter for Ventilators

A wide-ranging ultrasonic gas concentration meter that is active in fields such as healthcare, electronics, and industry. We have compiled a collection of case studies featuring selected examples of its adoption.

A ventilator is a medical device that artificially assists breathing for individuals with insufficient spontaneous respiration over a long period, ranging from several hours to several years. Our ultrasonic gas module is installed in this device and is used to monitor the oxygen concentration supplied to the patient from the device. Target device: US-100-5VS type.2 *There are many other industries where it is actively used. Please download our case study collection and consult with us. If you would like a free demo, please let us know.

  • Analytical Equipment and Devices
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Case Study: Process Gas Sealing Process - Ultrasonic Gas Concentration Meter

An ultrasonic gas concentration meter that is actively used in a wide range of fields, including healthcare, electronics, and industry. We have compiled a collection of case studies highlighting selected examples of its adoption.

In the electronics and semiconductor fields, our ultrasonic gas concentration meter is used to monitor and manage gas concentration during the encapsulation process of a certain process gas. Target equipment: US-2T series *There are many other industries where our products are actively used. Please download our case study collection and consult with us. If you would like a free demo, please let us know.

  • Analytical Equipment and Devices
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Application Example: Greenhouse Gas Concentration Measurement - Ultrasonic Gas Concentration Meter

An ultrasonic gas concentration meter that is actively used in a wide range of fields, including healthcare, electronics, and industry. We have compiled a collection of case studies highlighting selected examples of its adoption.

As greenhouse gases, carbon dioxide, methane, and sulfur hexafluoride (SF6) are mentioned, among which sulfur hexafluoride is widely used in power-related processes and as an insulating gas in semiconductors. In terms of global warming potential, if carbon dioxide is set at 1, sulfur hexafluoride is 22,800. In recent years, efforts have been made by various companies to prevent the release of sulfur hexafluoride into the atmosphere by installing recovery devices and other measures. Our ultrasonic gas concentration meter is incorporated into such recovery devices and is also used for portable measurement of SF6 concentration. Additionally, in Japan, our ultrasonic gas concentration meter is used for measuring the concentration of alternative refrigerants, which are required to be recovered after use under the Freon Recovery and Destruction Law, as it can measure concentrations that other methods cannot. Target models: US-2T series, US-100-5VS type.2 *There are many other industries where our products are actively used. Please download our case study collection and consult with us. If you would like a free demo, please let us know.

  • Analytical Equipment and Devices
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Case Study: Vacuum Equipment and Vacuum Furnace - Zirconia Oxygen Analyzer

Active in a wide range of fields including electronics, industry, and healthcare. Selected cases have been compiled into a case study collection.

The atmospheric pressure is 1 atmosphere (1013.25 hPa). A space with lower pressure than this atmospheric pressure is called a vacuum. By creating a vacuum, it is possible to prevent the oxidation of processed materials, which is why vacuum devices and vacuum furnaces are used in many material product processes. Our zirconia-based oxygen analyzer can measure a range from ppm O2 concentration to 10×-30 atm O2. Applicable models: TB-2F series, TB-2V series *There are many other industries where our products are actively used. Please download our case study collection and consult with us. If you would like a free demo, please let us know.

  • Analytical Equipment and Devices
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Case Study: Marine (Tanker) Zirconia Oxygen Analyzer

Active in a wide range of fields including electronics, industry, and healthcare. We have picked up selected cases and compiled them into a case study collection.

When transporting heavy oil with a tanker, friction between the heavy oil and air inside the tank can cause an explosion due to turbulence during operation. To prevent this, tankers mix nitrogen or inert gases with the air to avoid explosions. Nitrogen is generated using a nitrogen generation unit, and inert gases are reused from boiler exhaust. This is called the Inert Gas System (I.G.S). Our oxygen meters are incorporated into the I.G.S, measuring the O2 concentration in the exhaust gas, and are actively used worldwide to prevent explosions during operation, as well as during loading and unloading. Achievements: Over 1,000 vessels. Target models: TB-2F series *There are many other industries where our products are actively used. Please download our case study collection and consult with us. If you would like a free demo, please let us know.

  • Analytical Equipment and Devices
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Adoption Case: Marine (Chemical Tanker / Container Ship) Zirconia Oxygen Meter

Active in a wide range of fields including electronics, industry, and healthcare. We have picked up selected cases and compiled them into a case study collection.

In Japan, various goods are imported from countries around the world. The transportation methods are either by air or by ship, but in the case of ships, there is significant swaying, and for chemical products, there is a risk of explosion due to friction. Therefore, nitrogen generation devices are used to lower the oxygen concentration and prevent explosions in advance. Additionally, for food products, nitrogen generation devices are also used to lower and manage the oxygen concentration to prevent spoilage. Our zirconia oxygen analyzers are built into such nitrogen generation devices to monitor the oxygen concentration. Target models: TB-2F-P, CG-SM *There are many other industries where our products are actively used. Please download our case study collection and consult with us. If you would like a free demo, please let us know.

  • Analytical Equipment and Devices
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Case Study: Oxygen Generation Device - Zirconia Oxygen Analyzer

Active in a wide range of fields including electronics, industry, and healthcare. We have picked up selected cases and compiled them into a case study collection.

In paper mills, steelmaking, incinerators, and other industries, a large amount of oxygen is required in the processes. Oxygen generation systems extract oxygen from the air and are used to improve combustion efficiency in furnaces and in various processes. Additionally, smaller units are used for home healthcare purposes. Our zirconia-type oxygen analyzers are generally used for industrial oxygen generation systems. Target model: FG-2UX *There are many other industries where our products are actively used. Please download our case studies for reference and feel free to consult us. If you would like a free demo, please let us know.

  • Analytical Equipment and Devices
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Studies] Zirconia-type Oxygen Meter (Oxygen Concentration Meter)

In various fields such as electronics, industry, and medicine, it plays an active role in measuring oxygen concentration. You can download a collection of representative case studies.

The oxygen concentration meter from Daiichi Thermal Research Co., Ltd. has been developed and improved to meet customer needs and is used in various applications. It also excels in robustness and maintenance, contributing to the satisfaction of many users. Additionally, as applied products, we manufacture unique items such as combustible gas analyzers, high-temperature gas moisture meters, and oxygen pumps, in response to user needs beyond standard oxygen measurement. 【Featured in Case Studies!】 - Measurement of boiler flue gas - Measurement of furnace atmosphere - Vacuum equipment and vacuum furnaces - Tankers - Chemical ships and container ships - Nitrogen generation systems - Oxygen generation systems - Atmosphere management and oxidation prevention in the electronics and semiconductor fields - Nitrogen reflow furnaces *There are many other industries where our products are actively used. Please download our case study collection and consult with us. If you would like a free demo, please let us know.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Application Example: Customized Product for Specific Gas Concentration Measurement - Ultrasonic Gas Concentration Meter

We will enter into a confidentiality agreement and create customized products tailored to your needs.

We would like to introduce examples of the adoption of the "Ultrasonic Gas Concentration Meter." Our company also manufactures customized products tailored to our customers' needs under a confidentiality agreement. If you let us know your requirements, we will be happy to make suggestions, so please feel free to contact us. [Examples] ■ Applicable models: All series *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration