Load cell
Load cell
It is a slim precision compression load cell made of all stainless steel.
- Company:三友電子工業
- Price:100,000 yen-500,000 yen
Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.
Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.
Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.
61~75 item / All 267 items
Load cell
It is a slim precision compression load cell made of all stainless steel.
Load cell
This is a small and lightweight load cell with a diameter of 12mm to 20mm.
Load cell
This is for a medium capacity scale. It is suitable for large weighing surfaces due to its height. OIML R60 certified product. Manufacturer link: http://www.minebea-mcd.com/product/loadcell/singlepoint/u2d1.html
Load cell
The measured load is slightly higher than the UL. It is a push-pull type.
Load cell converter
The A-820L is a load cell converter that uses the AD8221AR low-noise instrumentation amplifier IC from Analog Devices. It operates on a single +5V power supply and requires a current of 25mA. It has a built-in power supply for driving load cells and can be directly connected to a 350Ω load cell. It is equipped with trimmers for sensitivity adjustment and offset adjustment, making it easy to calibrate. The rated output is 2V (+2.5V±2V). The sensitivity adjustment range is 0.5mV/ to 2.2mV/V. The offset adjustment range is +2.5V±0.5V. It uses a one-touch terminal block ML-950-4 (Sato Parts) for input and output. The external dimensions are 70×40×16.
±10V output load cell converter
Load cell converter using Analog Devices' low-noise instrumentation amplifier IC, AD8221AR. Rated output is ±10V/FS, with a response frequency of 2.8kHz (-3dB). It has a built-in +5V power supply for driving the load cell and can be directly connected to a 350Ω load cell. Equipped with a trimmer for sensitivity adjustment and a trimmer for offset adjustment, making it easy to adjust. Sensitivity adjustment range is 0.5mV/ to 2.2mV/V, and offset adjustment range is ±1.8V. Required power supply is ±12 to 15V, 20mA. A one-touch terminal block ML-950-4 (Sato Parts) is used for input and output. External dimensions are 70×40×16.
A load cell converter equipped with two comparators, operating on a +24V power supply, with a rated output of ±10V/FS.
A load cell converter that operates on a +24V power supply, with a rated output of ±10V/FS. It is equipped with two comparators, allowing for judgment output and one-shot output by comparing with set values. It is ideal for use in combination with sequencers and other devices. The rated output is ±10V/FS, and the response frequency is 350Hz (-3dB). It has a built-in +5V power supply for driving load cells, allowing direct connection to a 350Ω load cell. It features trimmers for sensitivity adjustment and offset adjustment, making it easy to calibrate. The sensitivity adjustment range is from 1mV/V to 4mV/V, and the offset adjustment range is ±1.8V. The required power supply is 24V, 40mA. The input and output use a one-touch terminal block. The external dimensions are 80×55×17.5.
Load cell amplifier
The A-822L is a load cell amplifier that incorporates a power supply for driving load cells and can be directly connected to a 350Ω load cell, using the low-noise measurement amplifier IC (Analog Devices AD8221AR). It operates on a single +5V power supply with a required current of 25mA. It is equipped with trimmers for sensitivity adjustment and offset adjustment, making it easy to calibrate. Rated output: 2V, sensitivity adjustment range: 0.5 to 2.2mV, offset adjustment range: +2.5V ±0.5V. The response frequency is kept low, resulting in minimal residual output noise.
Load cell amplifier
The A-832L is a load cell amplifier that incorporates a power supply for driving load cells and can be directly connected to a 350Ω load cell. It uses a low-noise measurement amplifier IC (Analog Devices AD8221AR) and operates with a power supply of ±12V to 15V, requiring a supply current of 20mA. It is equipped with trimmers for sensitivity adjustment and offset adjustment, making it easy to calibrate. Rated output: ±10V, sensitivity adjustment range: 0.5 to 2.2mV, offset adjustment range: ±1.8V. The response frequency is kept low, resulting in minimal residual output noise.
Ultra-low noise load cell converter for measuring instruments
Ultra-low noise load cell converter for measuring instruments
Ultra-low noise load cell converter for measuring instruments
Ultra-low noise load cell converter for measuring instruments
Small load cell converter.
The A-520L is a compact load cell converter that operates on a single 5V power supply. It has a built-in power supply for driving load cells and can be directly connected to a 350Ω load cell.
The AL6 is a load cell converter that uses a 24-bit sigma-delta AD converter.
AL6 is a load cell converter that uses a 24-bit sigma-delta AD converter.
Wide grip/jig usage is possible! It enables easy and error-free operation.
The "2580 Series Static Load Cell" is designed for use with the 5900 testing system and offers excellent performance, including the ability to measure loads at 1/1000 of the load capacity with an accuracy of 0.5% of the reading value. With automatic recognition and automatic calibration features, load cells in this series are easy to operate, can withstand loads up to 150% of their load capacity without damage, and do not experience mechanical failure even under loads of up to 300%. All Instron load cells are individually temperature compensated and undergo accuracy and repeatability testing with traceable calibration instruments according to international standards, resulting in measurement uncertainty being less than 1/3 of the load cell's allowable error. 【Features】 ■ Load capacity: ±500 N to ±600 kN (50 to 60,000 kgf) ■ Suitable for a wide range of test types (including tension, compression, single and double swing repeated stress, etc.) ■ Overload capacity of 150% of the load capacity - reduces the risk of damage ■ Fixture weight of 10% of the load capacity - allows for extensive use of grips/fixtures *For more details, please refer to the PDF document or feel free to contact us.