We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

column Product List and Ranking from 68 Manufacturers, Suppliers and Companies | IPROS GMS

Last Updated: Aggregation Period:Mar 18, 2026~Apr 14, 2026
This ranking is based on the number of page views on our site.

column Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Mar 18, 2026~Apr 14, 2026
This ranking is based on the number of page views on our site.

  1. アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  2. 東ソー バイオサイエンス事業部 計測分野 Tokyo//Chemical
  3. 日本ウォーターズ(米国本社 Waters Corporation)  Tokyo//Testing, Analysis and Measurement
  4. 4 サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K. Tokyo//Testing, Analysis and Measurement
  5. 5 Sartorius Stedim Japan K.K. Tokyo//Pharmaceuticals and Biotechnology

column Product ranking

Last Updated: Aggregation Period:Mar 18, 2026~Apr 14, 2026
This ranking is based on the number of page views on our site.

  1. Innovative solid-phase extraction column Oasis PRiME HLB 日本ウォーターズ(米国本社 Waters Corporation) 
  2. ACQUITY UPLC column 日本ウォーターズ(米国本社 Waters Corporation) 
  3. The non-denaturing analysis of antibody-drug conjugates (ADCs) is settled with this! 東ソー バイオサイエンス事業部 計測分野
  4. Resolute Linear Chromatography Column Sartorius Stedim Japan K.K.
  5. 4 GC column "SE-30/SE-54" アジレント・テクノロジー株式会社

column Product List

271~300 item / All 651 items

Displayed results

Peptide mapping and separation of low molecular weight proteins using a mobile phase.

Peptide mapping using formic acid allows for more sensitive detection with ESI-MS.

Peptide mapping using formic acid instead of TFA enables more sensitive detection with ESI-MS. The CSH130 C18 shows outstanding performance regardless of the acidic modifier used, making it ideal for LC/MS-based peptide mapping. In LC/MS analysis using a formic acid mobile phase for enolase tryptic digest, the CSH130 C18, 1.7μm column achieved a 30% higher peak capacity compared to common fully porous or superficially porous C18 columns of the same particle size. Furthermore, analysis results of high molecular weight peptides and low molecular weight proteins demonstrated that the CSH130 C18 column with a pore size of 130Å is suitable for the separation of polypeptides up to approximately 10 kDa in molecular weight. 【Application Benefits】 - High peak capacity and unique selectivity compared to other C18 columns - Compatibility with formic acid and ESI-MS - High separation ability for analytes up to approximately 10 kDa - CSH130 C18 has been QC tested with cytochrome c tryptic digest For more details, please contact us or download the catalog.

  • Other laboratory equipment and containers
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ACQUITY APC Column

Faster and higher-resolution analysis than conventional GPC.

The ACQUITY APC column provides advanced packing technology for the separation of complex synthetic polymers and macromolecular species, delivering superior performance and reliability for high-resolution polymer characterization compared to conventional GPC columns. The ACQUITY APC column further enhances Advanced Polymer Chromatography as follows.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low-adsorption LC column MaxPeak Premier column

Effectively reduce non-specific adsorption (NSA) of compounds that easily adsorb to metals, providing excellent durability and consistency over a long period.

This is a low-adsorption column that employs MaxPeak HPS technology, which minimizes the interaction between the analyte and column hardware (column tube) that can cause sample loss, thereby improving the recovery rate, sensitivity, and reproducibility of the analyte. MaxPeak HPS technology is an advanced surface treatment technology rather than a resin coating. It is designed to withstand the rigorous conditions of high-throughput laboratories, providing excellent performance that lasts without compromise. 【Features】 - Reduces the effort and time required for column conditioning and passivation - Improves sensitivity and peak shape - Allows analysis with a simpler mobile phase that does not contain complex additives - Saves time in method development - Reduces risk and enhances reliability in data and decision-making - A lineup compatible with all LC systems including UPLC/UHPLC/HPLC

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Sample pretreatment system for mass analysis

We will resolve the bottleneck in sample preparation.

Solid Phase Extraction (SPE), Liquid-Liquid Extraction (LLE), and Protein Purification - Tecan provides automation for a consistent process. ● Solid Phase Extraction (SPE) System: The solid phase extraction system caters to a wide range of fields including pharmaceuticals, forensics, food, clinical, and bioanalysis. ● Liquid-Liquid Extraction (LLE) System: The liquid-liquid extraction system supports the automation of fast, robust, and safe sample purification and quantification. ● Protein Digestion System: Automation of protein digestion to enhance peptide recovery and assay throughput. *For more details, please download the PDF or contact us.*

  • LCMS_固相抽出.jpg
  • LCMS_液液抽出.jpg
  • LCMS_タンパク質.jpg
  • Dispenser
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

General-purpose SPE (Solid Phase Extraction) purification column Cerex Atlas

The Cerex Atlas series is an SPE purification column with a balanced hydrophilic and hydrophobic characteristic, suitable for a wide range of analytical compounds.

Cerex Atlas SPE purification column The balanced hydrophilic-hydrophobic polymer adsorbent is composed of N-vinylpyrrolidone-divinylbenzene copolymer. It has selectivity for both polar and non-polar functional groups in analytes, allowing users to easily purify a variety of samples. The hydrophobic framework of divinylbenzene provides selectivity for hydrophobic functional groups, while the hydrophilicity of pyrrolidone helps enhance interactions with polar functional groups in analytes. *For more details, please download the PDF or contact us.*

  • A200_2.jpg
  • Dispenser
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

T054 NFC Key Management System for Banks and Security Companies

Utilize NFC tags with opening detection features for managing keys at banks and security companies to prevent unauthorized access!

Recently, there was news about valuables being stolen from bank safety deposit boxes using spare keys. It is possible to prevent such incidents by attaching an NFC tag with an opening detection feature to the envelope! What is an NFC tag with an opening detection feature? It is a special label that has an opening detection function added to an NFC tag that can be read simply by touching it with a smartphone. When the label is torn and touched with a smartphone, it changes from "unopened" to "opened." This prevents the outflow of keys placed in an opened key and helps prevent unauthorized opening of the envelope! By using it in conjunction with an NFC item management system, it is also possible to manage the borrowing and returning of keys! 【Features of the NFC Item Management System】 1. Simple operation with just a touch You can register lending, returning, and moving by simply touching the NFC tag with your smartphone. 2. Real-time management and tracking Data is centrally managed in the cloud. The location, usage history, and users of items can be tracked in real-time! 3. Strong traceability Records are kept of "when," "where," and "what was used," allowing for identification of causes and clarification of responsibilities in the event of a problem!

  • Other core systems
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Biocolumn

A separate type filter that allows you to choose the type and is easy to replace.

The bio-column is a patented product devised by General Fujita, and our company is authorized to sell it. The filters include glass filters, sintered SUS filters, and Teflon mesh plates, which can be easily removed for cleaning, allowing users to choose the type of filter according to their needs.

  • Glassware and containers
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

LC and LC/MS columns

We cater to various applications and needs such as low molecular weight, medium molecular weight, and bioanalysis!

In 2010, our company was able to enhance its LC column lineup by integrating with Varian. In addition to the traditional ZORBAX products, the addition of many new columns for gel filtration/size exclusion, ion exchange, and preparative LC columns allows us to cater to a wider range of applications and solutions than ever before. We provide industry-leading performance columns that deliver fast and reproducible results across various analyses, including traditional chromatography, ultra-fast chromatography, separation of biomolecules, and analysis of complex basic compounds. 【Product Lineup】 ■ Columns for low molecular weight analysis: Poroshell120, ZORBAX ■ Columns for bioanalysis: AdvanceBio SEC, HIC, glycan mapping, oligonucleotides, peptide mapping, amino acid analysis ■ GPC/SEC columns *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Food Nutrition Labeling Test Agilent J&W GC Column

Accurate measurement of total fat content is essential to comply with food identification and nutrition labeling laws.

To optimize the processing, flavor, texture, and shelf life of food products, it is necessary to thoroughly test the oils and fats contained within them. The 'Agilent J&W GC Column' for the analysis of fats and oils has been developed and tested for the qualitative and quantitative analysis of FAME, free fatty acids, and triglycerides. By utilizing Agilent's comprehensive and innovative column portfolio, samples—whether simple or complex—can be separated accurately and with high reproducibility in a short amount of time. 【Features】 ■ Maintains the highest standards of components, quality, and purity ■ Developed for the qualitative and quantitative analysis of AME, free fatty acids, and triglycerides ■ Accurately separates samples in a short time with high reproducibility ■ Enables highly reliable qualitative and quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

DB-FATWAX Ultra Inert

Achieving high inactivity with difficult-to-separate fatty acids, resulting in improved selectivity of fatty acid methyl esters!

The "DB-FATWAX Ultrapure" is a WAX-type GC column specialized for applications. It is well-suited for the analysis of methyl esters of unsaturated/polyunsaturated fatty acids found in fish oil and animal fats. Thanks to Agilent's unique Ultrapure technology, which offers excellent inertness and thermal stability, it is also suitable for the analysis of challenging non-derivatized fatty acids. 【Features】 ■ Individually tested with FAME mixtures ■ Reproducible FAME equivalent chain length values ■ Highly reliable inert performance between columns ■ Improved peak shape for challenging polar compounds such as free fatty acids ■ High polarity, equivalent to USPG16 ■ The chemical bonding and cross-linked stationary phase of the column can be cleaned with solvents ■ Compatible with the injection of water-soluble samples *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "HP-1ms"

Introduction of a non-polar low bleed GC/MS column that can be cleaned with solvent using chemical bonding and cross-linking type!

The "HP-1ms" is a low bleed GC/MS column that improves sensitivity and the reliability of mass spectra due to an enhanced S/N ratio. Agilent offers a wide range of columns among column manufacturers worldwide. Our commitment to reliability and reproducibility of products supports the improvement of quality levels demanded by chromatography professionals. We continue to pursue further enhancements in analytical performance standards, such as separation efficiency, reproducibility of retention times, and peak height ratios. 【Features】 ■ 100% Dimethylpolysiloxane ■ Equivalent selectivity to HP-1 ■ Non-polar ■ Ultra-low bleed ■ Suitable as a general-purpose column *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

DB-624UI Ultra Inert Capillary GC Column

Ideal for environmental and chemical samples containing unknown components! Separates trace amounts of active target compounds with high reliability.

We would like to introduce our product, the "DB-624UI Ultra Inert Capillary GC Column." It is optimized for the rapid analysis of volatile target compounds and is ideal for environmental and chemical samples containing unknown components. Thanks to Agilent's unique passivation process, peak shape and S/N levels are improved, enhancing the sensitivity for qualitative and quantitative analysis. 【Features】 - Improved peak shape and linearity to provide the highest level of column inertness. - Enhanced detection limits allow for more reliable quantification of trace active target compounds. - Capable of reliably separating trace active target compounds. - Achieves top-class sensitivity and separation capability for key compounds specified in USP Method <467> analysis. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

C18 column "CP-Sil 13 CB"

Solvent washing is possible in chemically bonded liquid phases! Suitable for detection by ECD with a non-cyano medium-polarity column.

The "CP-Sil 13 CB" is a medium-polarity column developed for appropriate analysis using methods that detect ECD, such as halocarbons. The liquid phase consists of 14% phenyl and 86% dimethylpolysiloxane, and since it does not contain cyano propyl, there is no observed baseline rise with ECD detection. It allows for solvent washing with a chemically bonded liquid phase, making it ideal as a confirmation column for analysis. 【Features】 ■ Solvent washing is possible with a chemically bonded liquid phase ■ Ideal as a confirmation column for analysis ■ Suitable for ECD detection with a non-cyano medium-polarity column *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-35"

Pursuing further improvement in analysis performance standards such as separation efficiency and peak height ratio!

We would like to introduce the GC column "DB-35" that we handle. It has a slightly higher polarity than medium polarity (HP-35) and low bleed. It is inert to active solutes and suitable for confirmation analysis. It is a chemically bonded and cross-linked type, allowing for solvent washing. 【Features】 ■ (35%-phenyl) methyl polysiloxane ■ Slightly higher polarity than medium polarity (HP-35) ■ Low bleed ■ Inert to active solutes ■ Suitable for confirmation analysis *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC Column "HP-35"

Methyl siloxane column with substituted phenyl groups! Suitable for EPA Method 8081.

We would like to introduce the GC column "HP-35" that we handle. This is a methyl siloxane column with phenyl groups substituted. This column is suitable for EPA Method 8081 and is equivalent to USP G-42. Additionally, due to its medium polarity, it is suitable for the analysis of pesticides, herbicides, pharmaceuticals, and amines. 【Features】 ■ (35%-phenyl) methyl polysiloxane ■ Slightly lower polarity than medium polarity (DB-35) ■ Inactive towards active solutes ■ Suitable for confirmatory analysis ■ Chemically bonded and cross-linked type *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-200"

Suitable for separating difficult-to-separate positional isomers! Introducing a medium-polarity column of methyl polysiloxane.

We would like to introduce our product, the "DB-200." It is a medium-polarity column made of (35% trifluoropropyl) methylpolysiloxane. It has a higher polarity than the medium-polarity "DB-1701" and "DB-17," and exhibits unique interactions with compounds containing nitro groups, halogen groups, and carbonyl groups. 【Features】 ■ (35% trifluoropropyl) methylpolysiloxane ■ Temperature limit 300/320℃ ■ Higher polarity than medium-polarity "DB-1701" and "DB-17" ■ Suitable for difficult-to-separate positional isomers ■ Exhibits unique interactions with compounds containing nitro groups, halogen groups, and carbonyl groups *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-INNOWax"

Excellent reproducibility of inter-column inertness! Solvent cleaning possible with chemical bonding and cross-linking type.

"HP-INNOWax" is a polyethylene glycol (PEG) stationary phase characterized by high polarity and a high temperature limit. It corresponds to the USP (United States Pharmacopeia) G16 liquid phase and is intended for applications such as food, fragrances, and perfumes. The improved Agilent J&W HP-INNOWax GC column series utilizes an innovative inert treatment also employed in the manufacturing of Agilent J&W DB-Wax ultra-inert columns. These columns maintain excellent inertness over the long term, even after repeated temperature cycling up to the column's upper temperature limit. 【Features】 ■ High polarity ■ PEG bonded phase with the highest temperature limit ■ Achieves sharp, symmetrical peak shapes for highly active polar compounds ■ Excellent reproducibility of inter-column inertness ■ Solvent-washable with chemical bonding and cross-linking type ■ Corresponds to USP G16 liquid phase *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil PONA for ASTM D-5134"

Fully compliant with the specified dimensions of the ASTM method! Inactive against polar additives.

"CP-Sil PONA for ASTM D-5134" is a standard test method for the detailed analysis of petroleum naphtha using n-nonane by capillary gas chromatography, optimized for ASTM D 5134. The column dimensions fully comply with ASTM D 5134. Due to undergoing tests based on the industry's very stringent QC specifications regarding column bleed, sensitivity, and efficiency, it is possible to obtain highly reliable qualitative and quantitative results. 【Features】 ■Reliable PONA analysis compliant with ASTM D 5134 ■Fully compliant with the specified dimensions of ASTM methods ■Inert to polar additives, allowing for high-quality data quality ■Highly reliable qualitative and quantitative results can be obtained *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-ProSteel"

Available with various stationary phases! Can be easily installed without special ferrules.

"DB-ProSteel" is deactivated through a special processing method, making it a column with excellent inertness. A column for GC ovens with a small winding diameter is also available. The outer diameter is 0.53mm, which is the same as the inner diameter of standard megabore columns. Therefore, it can be easily installed without any special ferrules. 【Features】 ■ High inertness ■ Excellent durability ■ Usable with various stationary phases ■ Chemical bonding and cross-linked type ■ Suitable for high-temperature analysis and process applications *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC Column "Select Volatiles"

The peak shape is very good! This is an application column optimized for environmental analysis.

"Select Volatiles" is an application column that resolves the peak shape of 1,4-dioxane and the separation of 1,4-dioxane-d8 and 1,2-dichloropropene. Due to its inner diameter of 0.20 mm, it is effective in reducing analysis time and saving helium gas. Additionally, it excels in reproducibility and durability for purge and trap-GC/MSD and headspace-GC/MSD analyses. 【Features】 ■ The peak shape of 1,4-dioxane is very good. ■ 1,4-dioxane-d8 and 1,2-dichloropropane are baseline separated. ■ The inner diameter of 0.20 mm is effective in reducing analysis time and saving helium gas. ■ Excellent reproducibility and durability in purge and trap-GC/MSD and headspace-GC/MSD analyses. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

UHPLC column

Equivalent selectivity to existing ZORBAX columns! Optimize separation by changing the stationary phase!

This product is a UHPLC column that achieves a maximum operating pressure of 120 MPa. When combined with the Agilent 1290 Infinity LC System, it delivers the highest level of performance. It is suitable for continuous analysis with durability and stable reproducibility, making it compatible with high-pressure UHPLC systems from various manufacturers. 【Features】 ■ Achieves a maximum operating pressure of 120 MPa through optimization of hardware and packing processes ■ Delivers the highest level of performance when combined with the Agilent 1290 Infinity LC System ■ Equivalent selectivity to existing ZORBAX columns ■ Durability and stable reproducibility suitable for continuous analysis ■ Compatible with high-pressure UHPLC systems from various manufacturers *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ZORBAX column / Poroshell column

Dramatic improvement in productivity! Flexibility and scalability of methods for low molecular weight and biomolecule analysis.

The "ZORBAX Columns / Poroshell Columns" are specially designed products for HPLC analysis with high productivity. The silica used is of extremely high purity, very robust, and highly uniform, providing the highest level of reliability. Additionally, one of the features is the extremely wide range of phases and column configurations that cater to diverse application needs. 【Features of ZORBAX Columns】 ■ Excellent options and flexibility for low molecular weight and reversed-phase biomolecule analysis with over 18 phases, including Eclipse Plus and HILIC ■ Easy method development that demonstrates excellent performance across a wide range of target compounds and conditions ■ Improvement of UHPLC methods ■ Outstanding peak shape performance due to proven innovative silica and bonding technology ■ Long-term reliability by having the necessary options available when needed for analysis and preparative purification *For more details, please refer to the PDF materials or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Fully porous HPLC column

You can easily change the method from a fully porous particle column to a surface porous particle column!

The product features various advantages of fully porous particle columns, such as high retention, load capacity, and solvent resistance. It can be expanded to suit your method, from UHPLC to preparative LC. Additionally, the InfinityLab Poroshell bonded phase is compatible with the traditional ZORBAX bonded phase, allowing for easy method changes from fully porous particle columns to superficially porous particle columns. 【How to choose the appropriate particle for your method (partial)】 ■1.8μm ZORBAX RRHD: Achieves the highest level of performance with UHPLC equipment - Maximum pressure: 1200 bar - Compatible systems: 1290 Infinity II LC or 1260 Infinity II Prime LC ■1.8 ZORBAX RRHT: Ultra-fast chromatography with a maximum of 600 bar - Maximum pressure: 600 bar - Compatible systems: 1260 Infinity II LC *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

InfinityLab Poroshell 120 Column

Method development is quick and easy! Compatible with almost all LC systems, with 12 types of fillers available.

The "InfinityLab Poroshell 120 Column" enhances analytical efficiency and reliability, significantly improving the performance of various instruments. Whether you desire superior HPLC performance, want to achieve UHPLC performance at lower pressures, or are seeking the highest level of UHPLC performance, this column is suitable for you. Available in three particle sizes: 1.9μm, 2.7μm, and 4μm, allowing you to choose the appropriate particle size based on your separation needs. 【Features】 ■ A column with innovative chiral stationary phase on porous surface particles ■ High-speed, high-separation column that increases throughput and separation capability ■ Excellent inter-batch reproducibility that consistently delivers reliable separation results ■ Selectable particle sizes Particle sizes of 1.9μm, 2.7μm, and 4μm maximize the performance of methods and instruments *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ZORBAX Eclipse XDB

An ideal choice for method analysis! Long lifespan at neutral pH due to high-density chemical bonding and double-end capping.

The "ZORBAX Eclipse XDB column" is designed to separate basic, acidic, and neutral compounds with good peak shape over a pH range of 2 to 9. It features a fully porous spherical packing material with a particle size of 1.8 μm suitable for Rapid Resolution High Throughput (RRHT). The Eclipse XDB-C18 and C8 provide high separation efficiency and long column life in the neutral range. Additionally, method optimization can be achieved by changing the mobile phase, pH, column temperature (up to 60°C), or by switching the stationary phase to Eclipse XDB-Phenyl. 【Features】 ■ Excellent peak shape for bases, acids, and neutral substances ■ Fully porous spherical packing material with a particle size of 1.8 μm suitable for Rapid Resolution High Throughput (RRHT) ■ Expanded pH range from 2 to 9 ■ Long lifespan at neutral pH due to high-density chemical bonding and double-end capping *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ZORBAX StableBond Column

Ideal for method development! A wide range of selectivity is achieved with five different types of chemically bonded stationary phases.

The "ZORBAX StableBond column" uses a unique monofunctional silane with bulky diisopropyl or diisobutyl groups in the side chains to suppress the hydrolysis of siloxane bonds, which is key to durability at low pH. StableBond packing does not undergo end-capping to maintain excellent stability, long column life, and better reproducibility in acidic mobile phases. The use of high-purity, low-acidity silica results in excellent peak shapes for acidic, basic, and neutral compounds. 【Features】 ■ Achieves long column life and top-class reproducibility at low pH levels down to pH 1 ■ Stable chemical treatment using proprietary technology ensures no degradation even at high temperatures and low pH ■ A wide range of selectivity is obtained with five different chemically bonded stationary phases ■ Excellent peak shape due to high-purity silica * For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ZORBAX Eclipse XDB-CN

Introducing the ZORBAX normal phase HPLC columns with both combined and non-combined filler series!

We would like to introduce the 'ZORBAX Eclipse XDB-CN' that we handle. We offer both bonded and non-bonded filler series, which are suitable for the normal phase analysis of basic compounds. It equilibrates faster than ZORBAX Rx-Sil and can be used for many normal phase analyses similar to Rx-Sil. 【Features】 ■ Manufactured from high-purity Rx-SIL ■ Equilibrates faster than ZORBAX Rx-Sil and can be used for many normal phase analyses similar to Rx-Sil *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ZORBAX Rx Reverse Phase HPLC Column

Rx-C18 is recommended for separation in low pH regions! It shows excellent stability and peak shape.

The "ZORBAX Rx Reverse Phase HPLC Column" is suitable for high-throughput analysis. It shows different selectivity compared to Eclipse XDB-C18 and StableBond SB-C18 in the low pH range, and StableBond is recommended for high-temperature applications. Additionally, Rx-C18 is manufactured using dimethyl octadecyl silane and demonstrates excellent stability up to pH 9 due to the lack of end-capping. 【Features】 ■ Shows different selectivity compared to Eclipse XDB-C18 and StableBond SB-C18 in the low pH range ■ Exhibits excellent stability and peak shape in low pH applications ■ Rx-C18 is manufactured using dimethyl octadecyl silane and demonstrates excellent stability up to pH 9 due to the lack of end-capping ■ Rx-C8 is the same product as SB-C8 *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ZORBAX Extend-C18

Improvement of retention, separation ability, and peak shape in base compounds! Introducing ZORBAX reverse phase HPLC columns.

The "ZORBAX Extend-C18" utilizes a groundbreaking bidentate C18-C18 bonding technology, enabling the development of high-separation methods in high pH regions while being a silica-based column. The unique bidentate bonding and double-end capping enhance stability at high pH. It improves retention, separation capability, and peak shape for basic compounds. To extend column life, it is preferable to use triethylamine, ammonium hydroxide, or pyrrolidine as buffer solutions, while phosphate buffers are not recommended. 【Features】 - High separation efficiency and long lifespan in high pH regions (up to pH 11.5) - Improved stability at high pH due to unique bidentate bonding and double-end capping - Higher efficiency and superior peak shape compared to polymer-based columns - High sensitivity and separation for LC/MS analysis of peptides and proteins *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration