Simple Press Hit Counter "SCM-024P" Patent No. 6985772
Introducing the foot press impact counter. It alleviates the concerns of quality managers with a patented system, addressing the lack of effective management methods until now.
This system monitors for forgotten processing or insufficient pressure in foot presses. It detects the impact force (acceleration) of the kick press cylinder using IPD, determining that pressure is acceptable when it exceeds a certain threshold. The head position is also monitored simultaneously, and if the head is at the processing position and the impact force is above the set level, an OK signal is sent to the SCM-024P to manage the hit points. This is a simple press counting dedicated machine with a function to prevent miscounts, developed from technology cultivated in welding counters. The IPD-01A is the standard model with functions for selecting the impact direction (positive, negative, or both) and switching the sensitivity of the impact sensor (two levels: 1x and 2x). The IPD-02A is a high-spec model that features an offset function to display the impact force indicator in a close-up view and allows for stepless adjustment of sensor sensitivity from 0 to 2.5 times.
- Company:ラムテクノロジーズ
- Price:100,000 yen-500,000 yen