We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Distribution Measuring Instrument.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Distribution Measuring Instrument Product List and Ranking from 38 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Oct 15, 2025~Nov 11, 2025
This ranking is based on the number of page views on our site.

Distribution Measuring Instrument Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Oct 15, 2025~Nov 11, 2025
This ranking is based on the number of page views on our site.

  1. null/null
  2. マウンテック Tokyo//Testing, Analysis and Measurement
  3. null/null
  4. ライフィクスアナリティカル Osaka//Pharmaceuticals and Biotechnology
  5. 5 スペクトリス株式会社 マルバーン・パナリティカル事業部 Hyogo//Testing, Analysis and Measurement

Distribution Measuring Instrument Product ranking

Last Updated: Aggregation Period:Oct 15, 2025~Nov 11, 2025
This ranking is based on the number of page views on our site.

  1. What kind of particle diameter is the volume average diameter [MV] in particle size measurement?
  2. 【Specific Surface Area・BET Method】Fully Automatic Specific Surface Area Measurement Device Macsorb マウンテック
  3. Technical Information: Specific Surface Area and Particle Diameter
  4. 4 Full Face Comprehensive Mask Thickness Distribution Measurement Device 東朋テクノロジー
  5. 5 Multi-sample and dispersibility evaluation particle size distribution measurement device "LUMiSizer" ライフィクスアナリティカル

Distribution Measuring Instrument Product List

16~30 item / All 113 items

Displayed results

Laser diffraction particle size distribution measurement device (small capacity measurement system)

<Used Analytical Equipment>

This is a laser diffraction particle size distribution measurement device with a measurement range of 17 nm to several hundred micrometers (depending on the viscosity of the dispersing medium and particle density). It is equipped with a batch cell (SALD-BC23) that allows measurement with a small amount of sample (target particles and dispersing medium). Organic solvents and acids can be used as the dispersing medium. (S2928-00)

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【Specific Surface Area・BET Method】Fully Automatic Specific Surface Area Measurement Device Macsorb

Automation and labor-saving of specific surface area measurement. Achieving high reproducibility and high precision through fully automated continuous measurement.

Surface area measurement device based on JIS Z8830. By adopting the BET flow method / single-point method, the measurement time is approximately 10 minutes per sample (excluding pretreatment). With an intuitive user interface, simple, robust, and safe hardware, and a design focused on measurement accuracy and reproducibility, it enables rapid and high-precision surface area measurements. By automating all processes from degassing to adsorption, desorption, and calibration, it prevents human error among operators. The addition of an auto-sampler allows for continuous operation of up to 30 samples, achieving fully unmanned operation day and night. 【Features】 - The device design, which pursues measurement accuracy and reproducibility in the BET flow method / single-point method, minimizes measurement time (multi-point method is optional). - User-friendly, intuitive interface does not require a high level of operator proficiency. - The addition of an auto-sampler enables unmanned operation for 8 to a maximum of 30 samples. - The measurement unit and auto-sampler have a unit structure, allowing for the addition of an auto-sampler after installation. - A wide range of options and accessories, such as external degassing devices (preheaters) and molded product measurement units, are available.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Probe-type inline particle size distribution measurement device Parsum

Measurement of particles up to 2500 microns is possible. Easy-to-install probe type.

A particle size distribution measurement device capable of measuring particles from 50 to 2500 microns. Since it is inserted directly into the piping, there is no need for sampling. Utilizing a patented laser-based optical fiber counting principle, it simultaneously measures particle size and velocity. Based on spatial filter velocity measurement methods and statistics, it calculates particle quantity and particle size distribution. Calibration is unnecessary, yet it provides stable measurements. 【Point】 - Measurement range: 50 μm to 6000 μm - Easy installation - Resistant to vibration and requires no calibration - Explosion-proof specifications available - Capable of particle measurement in strong acids, strong alkalis, and organic solvents 【Case Studies】 - Dry measurement in pharmaceutical lines - Particle measurement in beneficial insects in strong acids, strong alkalis, and organic solvents etc...

  • Optical Measuring Instruments
  • Analytical Equipment and Devices
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Laser diffraction online particle size distribution measurement device (dry type)

Why is there a thermometer and a pressure gauge, but no particle size meter? Laser diffraction online particle size distribution measurement device (dry type).

Which measuring device is suitable for your process? ↓  ↓  ↓ We have included a chart in the brochure, so please download it and check it out! 【Point】 - Installation methods suitable for the process are possible both online and inline. - In the case of inline installation, the piping diameter of the flow cell can be one of three sizes (1 inch, 2 inches, 3 inches). - Prevents powder adhesion to the optical window using air.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration