We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Reservoir.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Reservoir Product List and Ranking from 8 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

Reservoir Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

  1. 天昇電気工業 Tokyo//Automobiles and Transportation Equipment
  2. 明治ゴム化成 Kanagawa//Rubber products
  3. 水島ゴム工業用品 Okayama//Trading company/Wholesale
  4. 4 ラサ商事 東京、大阪、名古屋、札幌、仙台、広島、福岡、シンガポール、上海駐在員事務所 Tokyo//Industrial Machinery
  5. 5 関西化工 Osaka//Machine elements and parts

Reservoir Product ranking

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

  1. Plastic rainwater infiltration facility, underground rainwater storage tank. 天昇電気工業
  2. Rainwater storage tank and rainwater infiltration facility adoption [Nagano Prefecture] 天昇電気工業
  3. [Data] Retention Infiltration Method (Tenrain Scrum) <Structural and Technical Details> 天昇電気工業
  4. Rainwater Storage Tank "Aquatrap" 明治ゴム化成
  5. 4 Rainwater storage tank "New Pura-kun" 水島ゴム工業用品

Reservoir Product List

1~15 item / All 17 items

Displayed results

Rainwater storage tank and rainwater infiltration facility adoption [Nagano Prefecture]

The rainwater management volume is 1,215m3, and the type used is a storage type! Here is an example of its adoption in Nagano Prefecture!

We would like to introduce a case where the rainwater retention and infiltration material "Tenrain Scrum" was adopted in a parking lot in Nagano City, Nagano Prefecture. The type used is a retention type. The rainwater management capacity is 1,215m3. 【Case Study】 ■Location: Nagano City, Nagano Prefecture ■Category: Private ■Upper Use Purpose: Parking Lot ■Type: Retention Type ■Rainwater Management Capacity: 1,215m3 *For more details, please refer to the PDF document or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Rainwater storage tank - Rainwater infiltration facility adopted [Tokyo]

The rainwater management volume is 546m3, and the type used is infiltration type! Here is an example of its adoption in Tokyo!

This is an introduction to a case where the rainwater retention infiltration material "Tenrain Scrum" was adopted in a parking lot in Ota Ward, Tokyo. The type used is an infiltration type. The rainwater management volume is 546m3. 【Case Study】 ■Location: Ota Ward, Tokyo ■Category: Private ■Property: New construction of a commercial facility ■Upper usage purpose: Parking lot ■Type: Infiltration type ■Rainwater management volume: 546m3 *For more details, please refer to the PDF document or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Rainwater storage tank and rainwater infiltration facility adoption case study [Fukushima Prefecture]

The rainwater management volume is 7,736m3, and the type used is a storage type! Here is an example of its adoption in Fukushima Prefecture!

This is an introduction to a case where the rainwater retention and infiltration material "Tenrain Scrum" was adopted in a parking lot in Nihonmatsu City, Fukushima Prefecture. The type used is a retention type. The rainwater management volume is 7,736m3. 【Features】 ■ Location: Nihonmatsu City, Fukushima Prefecture ■ Category: Public ■ Project: New construction of a public facility ■ Upper usage purpose: Parking lot ■ Type: Retention type ■ Rainwater management volume: 7,736m3 *For more details, please refer to the PDF materials or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Comparison of Retention Infiltration Methods and Rainwater Runoff Control Facilities

Comparing plastic methods and crushed stone methods! We will also introduce the advantages of plastic rainwater infiltration facilities and underground rainwater storage tanks.

The document includes a comparison table of "retention infiltration methods and rainwater runoff control facilities." It lists the applications and performance characteristics such as the plastic method, concrete precast method, open retention basin method, and crushed stone method, as well as the shape of the tanks. Additionally, there is information about the advantages of plastic retention tanks, so please take a moment to read it. [Contents] ■ Comparison of retention infiltration methods and rainwater runoff control facilities ■ Advantages of plastic retention tanks ■ Article introducing the advantages of plastic retention tanks *For more details, please refer to the PDF document or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Data] Retention Infiltration Method (Tenrain Scrum) <Structural and Technical Details>

Versatile maintenance performance! We will introduce the construction procedures and specifications of Tenrain in the materials.

This document provides an explanation of the structure and technical details of the retention infiltration method and the Tenrain Scrum method. It includes detailed illustrations such as the "Installation Image of Tenrain," "Classification of Plastic Retention Tanks (Reference)," and "Characteristic Classification of Tenrain." Please feel free to download and read it. 【Contents (Excerpt)】 ■ Installation Image of Tenrain ■ Classification of Plastic Retention Tanks (Reference) ■ Characteristic Classification of Tenrain ■ Features of Tenrain ■ Specifications of Tenrain *For more details, please refer to the PDF document or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Case] Replacement Work of Hypochlorite Storage Tank at a Certain Water Purification Plant

Construction period: 45 days, working days: 3! We will introduce the renovation work due to the aging of the secondary storage tank.

We would like to introduce a case study of the replacement work for a sodium hypochlorite storage tank at a certain water purification plant handled by Kansai Chemical Co., Ltd. A problem arose because the piping was extensively laid out, making it impossible to deliver the storage tank as a single unit. As a countermeasure, we manufactured it in three parts and assembled it on-site to complete the installation. 【Project Data】 ■ Content: Renewal work due to aging of the sodium hypochlorite storage tank ■ Challenge: The extensive piping layout made it impossible to deliver the storage tank as a single unit ■ Countermeasure: Manufactured in three parts and assembled on-site for completion *For more details, please refer to the PDF materials or feel free to contact us.

  • Thermostatic chamber
  • tank
  • valve

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Reinforced Plastic Underground Storage and Infiltration Tank for Flood Control Measures "DRAIN PANEL"

A rainwater system for storage, infiltration, and recharge facilities, created through simple connections and stacking on-site.

The "DRAIN PANEL" is a modular product made from recycled plastic, designed to easily create underground rainwater tanks. It can be assembled through linking and stacking, and its high mechanical strength allows for the installation of tanks even in parking lots and busy roadways underground. Each module consists of 16 hollow, perforated pillars, with a void ratio of 96%. 【Features】 ■ Installation can be done manually ■ Panels interlock with each other by rotating 90° and placing them on the lower layer ■ High load-bearing design capable of withstanding large vehicles *For more details, please refer to the PDF document or feel free to contact us.

  • Municipal services and business location

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Amerio Case Study] Mie Forest and Forestry Academy Building

Utilizing rainwater for toilet flushing! Also useful during disasters!

We would like to introduce a case study of our "Amerio" system implemented at the "Mie Forest and Forestry Academy Building" located in Hakusan-cho, Tsu City, Mie Prefecture. This product is a rainwater storage and utilization system called "Amerio," consisting of a 3m3 rainwater storage tank, a rainwater purification device, and a chlorine sterilization device. Thanks to the solar power generation and storage system installed by Mie Prefecture, the system operates even during disasters, allowing for the use of flush toilets as usual. We also hold regular tours as a local achievement, so please feel free to contact us. 【Case Overview】 ■ Construction Location: Hakusan-cho, Tsu City, Mie Prefecture ■ Construction Period: 2023 ■ System: Amerio ■ Rainwater Storage Capacity/Utilization Method: 3m3/Flushing water for toilets, etc. ■ Client: Mie Prefecture *For more details, please refer to the PDF materials or feel free to contact us.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【アメリオ導入事例】萩太郎山山頂トイレ

雨水貯水・活用システムの施工事例!トイレの手洗い水用として設置

愛知県北設楽郡豊根村にある萩太郎山山頂トイレにて、 当社の『アメリオ』を導入した事例をご紹介します。 山頂トイレで水道がないので、雨水利用が採用されました。 当製品はトイレの手洗い水用として設置されており、 ソフィール循環も施工しております。 【事例概要】 ■工事場所 :愛知県北設楽郡豊根村 ■施工時期 :2017年 ■システム :アメリオ(雨水貯水・活用システム)、雨水貯留槽 地上設置型 ■処理水質 :整雨レベルIV、整菌レベルC ■雨水貯留量:3㎥ ■活用方法 :手洗い水、掃除用水 ■発注者  :豊根村役場 ※詳しくはPDF資料をご覧いただくか、お気軽にお問い合わせ下さい。

  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Putzmeister storage tank

Storage tank designed for high-concentration sludge such as dewatered sludge.

【Sliding Sludge Collection and Dewatering System】 The Putzmeister storage tank is specifically designed for high-concentration sludge, such as dewatered sludge. A sliding frame is mounted at the bottom of the tank, which moves back and forth to draw the sludge into the auger feeder attached below. The auger feeder efficiently fills the sludge into a pumping system or discharges it into transport vehicles.

  • Other process controls
  • Food environmental hygiene/contamination prevention equipment
  • Piping Materials

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Rainwater storage tank and rainwater infiltration facility adoption [Saitama Prefecture]

The rainwater management volume is 127m3, and the type used is a storage type! Here is an example of its adoption in Saitama Prefecture!

This is an introduction to a case where the rainwater retention infiltration material "Tenrain Scrum" was adopted in a parking lot in Kasukabe City, Saitama Prefecture. The type used is a retention type. The rainwater countermeasure volume is 127m3. 【Features】 ■Location: Kasukabe City, Saitama Prefecture ■Category: Public ■Project: New construction of a public facility ■Upper usage purpose: Parking lot ■Type: Retention type ■Rainwater countermeasure volume: 127m3 *For more details, please refer to the PDF materials or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Rainwater Storage Tanks and Rainwater Infiltration Facilities [Case Study Collection]

Using retention and infiltration types! Introducing examples of rainwater retention and infiltration in parking lots and grounds!

This document introduces examples of rainwater storage tanks and rainwater infiltration facilities. They are widely adopted in logistics warehouse parking spaces and large commercial facility parking lots, and are utilized regardless of scale in parks, grounds, and sports fields underground. This is an environmentally symbiotic product developed for disaster prevention and rainwater utilization. Examples include parking lots in Koga City, Ibaraki Prefecture, Ichihara City, Chiba Prefecture, and Kasukabe City, Saitama Prefecture, as well as grounds in Isehara City, Kanagawa Prefecture. In the parking lot of Nihonmatsu City, Fukushima Prefecture, a retention-type public facility was newly constructed. Please feel free to download and take a look. 【List of Examples (Partial)】 ■Fukushima Prefecture ■Ibaraki Prefecture ■Chiba Prefecture ■Saitama Prefecture ■Kanagawa Prefecture 【Features】 ■Inspection facilities are flexible ■Easy construction without joint materials ■Excellent work efficiency ■High retention rate ■Eco-friendly system It is possible to build underground facilities with high water storage capacity, excellent load-bearing capacity, and high versatility. *Please be sure to check the catalog and videos, and feel free to contact us. *For more details, please refer to the PDF document or feel free to inquire.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Plastic rainwater infiltration facility, underground rainwater storage tank.

Utilize the power of recycled plastic for disaster prevention and water resource management! It boasts excellent structural strength and a rainwater storage rate of over 95%.

Due to the long-term and frequent heavy rainfall caused by climate change, along with significant urbanization, serious flooding damage is occurring frequently. Rainwater retention and infiltration facilities temporarily store rainwater and gradually release it or allow it to infiltrate underground, which helps reduce the burden on drainage facilities such as rivers, sewer pipes, and rainwater pipes, mitigates flooding damage in inundated areas, and leads to effective utilization of rainwater. In addition to being a water source for disaster toilets, the advanced water purification filter technology developed in Japan can also create drinking water when combined with water storage tanks for disaster prevention. 【Features】 ■ Dramatic cost reduction effects ■ Fast, safe, and reliable construction ■ Load-bearing capacity + seismic performance + high water storage capacity ■ Long-term stabilization of recycled plastics *For more details, please refer to the PDF document or feel free to contact us.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Plastic rainwater storage tank

A plastic rainwater storage tank made by fitting and stacking plastic components.

■The main body material can be easily installed manually, and the side panel material can be attached with a single touch. ■Utilizing the communication structure inside the tank allows for cleaning operations using maintenance tools (self-propelled cameras, vacuum hoses), resulting in excellent maintainability. ■This material can be delivered to the site without using pallets, eliminating the need for pallet collection and industrial waste disposal after installation. ■The product complies with Environmental Agency Notification No. 46 "Environmental Standards Regarding Soil Contamination" and RoHS standards.

  • others
  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Amerio Case Study] Ugura Park (Ise-Shima National Park Observation Point)

An example of rainwater utilization in toilets within a national park without water supply.

We would like to introduce a case study of our "Amelio" system installed at Ukura Park (Ise-Shima National Park Observation Point) in Minami-Ise Town, Watarai District, Mie Prefecture. Ukura Park (Mie Island Observation Deck) is an observation point within the national park that offers a stunning view of the ria coastline, and it is known as a tourist spot for couples because the bay resembles a "heart shape." Since there is no water supply infrastructure at the observation point, rainwater is utilized for handwashing and cleaning water in the restrooms, maintaining comfort. Our soil microbial membrane purification tank (Sofeel recycling system) is installed for the toilet flushing water. We also hold tours as part of our local achievements in Mie Prefecture, so please feel free to contact us. 【Case Overview】 ■ Construction Location: Minami-Ise Town, Watarai District, Mie Prefecture ■ Construction Period: 2021 ■ System: Amelio (Rainwater Storage and Utilization System), Above-ground Rainwater Storage Tank ■ Treated Water Quality: Rainwater Level IV, Bacteria Level C ■ Rainwater Storage Capacity: 1.6㎥ ■ Utilization Method: Handwashing water, Cleaning water ■ Client: Mie Prefecture *For more details, please refer to the PDF document or feel free to contact us.

  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration