We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Spectroscopic Analyzer.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Spectroscopic Analyzer Product List and Ranking from 6 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

Spectroscopic Analyzer Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

  1. メトロームジャパン 本社 Tokyo//Testing, Analysis and Measurement
  2. 日本エリーズマグネチックス 浦安本社・工場、名古屋営業所、大阪営業所 Chiba//Industrial Electrical Equipment
  3. レックス Hyogo//Testing, Analysis and Measurement
  4. 4 日本非破壊検査 Okayama//Testing, Analysis and Measurement
  5. 4 日揮ユニバーサル Tokyo//Testing, Analysis and Measurement

Spectroscopic Analyzer Product ranking

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

  1. Near-infrared analyzer Polyvinyl alcohol saponification degree [Technical Data] メトロームジャパン 本社
  2. Laser-Induced Breakdown Spectroscopy Analyzer "Z-900 Series" 日本エリーズマグネチックス 浦安本社・工場、名古屋営業所、大阪営業所
  3. Uniformity of Content Testing for Tablets Using Near Infrared Analysis (NIR) [Technical Document] メトロームジャパン 本社
  4. 4 Simultaneous quantitative analysis of four components of PET resin using near-infrared analyzer [Technical Document] メトロームジャパン 本社
  5. 4 Analysis of Roasted Coffee Using Near Infrared Spectroscopy (NIR) [Technical Document] メトロームジャパン 本社

Spectroscopic Analyzer Product List

31~37 item / All 37 items

Displayed results

Technical Documentation on Bris (Sugar Content) in Juice Using Near Infrared Analyzer (NIR)

Simultaneous measurement of sugar content (Brix), glucose, fructose, and sucrose in fruit juice using near-infrared analyzer.

【Near Infrared Analyzer Technical Data 24 Food and Beverages】 When considering root juice as a product, the sugar content in the product is a very important parameter because it is a sweet beverage. Among these, the contents of fructose, glucose, and sucrose are considered very important sugars for quality control. Traditionally, to measure these sugars in fruit juice through laboratory analysis, liquid chromatography is used along with refractive index measurement. When there are multiple analytical methods like this, each analysis requires time and expertise, as well as the need for different analytical instruments. Near Infrared Spectroscopy (NIRS) is an analytical technique that can simultaneously measure glucose, fructose, sucrose, and Brix in fruit juice in under one minute. Furthermore, it does not require chemical reagents, and no sample pretreatment is necessary.

  • OMNIS-NIR-GIF--1-X2000.gif
  • Near-infrared spectrophotometer
  • Spectroscopic Analysis Equipment
  • Food/beverage component analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Analysis of Coffee Green Beans Using Near Infrared Spectroscopy (NIR) [Technical Document]

Easily measure the density, water activity, and moisture of green coffee beans all at once with a near-infrared analyzer.

[Near Infrared Analyzer Technical Data 25 Food and Beverages] Near Infrared Spectroscopy (NIRS) is an analytical method suitable for analyzing the density, water activity, and moisture content of green coffee beans. It does not require any chemicals or sample pretreatment, and NIRS can be easily used anywhere, whether near warehouses, roasters, or in analysis rooms.

  • OMNIS-NIR-GIF--1-X2000.gif
  • Spectroscopic Analysis Equipment
  • Near-infrared spectrophotometer
  • Food/beverage component analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Moisture Analysis of Fertilizers Using Near Infrared Analysis (NIR) [Technical Document]

Easily measure the moisture content in fertilizers in just a few seconds using a near-infrared analyzer.

Near Infrared Analyzer Technical Data 26 Agriculture Moisture in fertilizers is one of the most commonly measured parameters. Globally, regulations regarding different fertilizers vary, but local legal restrictions must not exceed the maximum moisture content. Various analytical techniques can be used for this moisture measurement. Following the gravimetric method, the Karl Fischer moisture meter is commonly used for accurate moisture measurement. Compared to these methods, near-infrared spectroscopy has unique advantages. It does not use chemical reagents and provides reliable results in just a few seconds. This application note introduces the analysis of moisture content in various fertilizer products using a near-infrared analyzer that allows for rapid and reagent-free analysis.

  • OMNIS-NIR-GIF--1-X2000.gif
  • Near-infrared spectrophotometer
  • Spectroscopic Analysis Equipment
  • Other physical property measurements and component analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Quality Control of CBD Oil Using Near-Infrared Analysis Equipment [Technical Document]

Rapid and easy measurement of cannabinoid content using near-infrared analysis (NIR)!

Near Infrared Analyzer Technical Data 28 Pharmaceuticals Cosmetics Cannabidiol (C-B-D) is a popular natural remedy used in many pharmaceuticals, foods, and cosmetics. CBD is just one of over 100 chemical compounds found in the cannabis plant. Unlike tetrahydrocannabinol (THC), CBD is non-psychoactive. This characteristic makes CBD an attractive option for those seeking relief from pain and other symptoms without the psychoactive effects associated with marijuana or resin concentrates. CBD oil is produced by extracting the compound from the plant and then diluting it with a carrier oil (such as coconut oil or hemp seed oil). The standard HPLC method takes a skilled analyst 45 minutes to perform the measurement. In contrast, the near-infrared analyzer (NIR) is a cost-effective and rapid analytical method for measuring cannabinoid content in oils.

  • OMNIS-NIR-GIF--1-X2000.gif
  • Spectroscopic Analysis Equipment
  • Analytical Equipment
  • Near-infrared spectrophotometer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Quality Control of Diesel Oil Using Near-Infrared Analyzers [Technical Document]

Rapid management of cetane index, flash point, CFPP, D95, and viscosity of diesel oil using near-infrared analyzer (NIR).

Near Infrared Analyzer Technical Data 31 Petroleum Related This technical document measures important quality parameters of diesel oil, including cetane index (ASTM D613), flash point (ASTM D56), CFPP: cold filter plug point (ASTM D6371), D95 (ISO 3405), and viscosity at 40 °C (ISO 3104).

  • OMNIS-NIR-GIF--1-X2000.gif
  • Spectroscopic Analysis Equipment
  • Fuel system parts

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Laser-Induced Breakdown Spectroscopy Analyzer "Z-900 Series"

Argon gas flushing using proprietary patented technology! An analyzer boasting a carbon detection limit of 0.008%.

The "Z-900 Series" is a new handheld analyzer capable of measuring carbon. In addition to pre-treatment of the sample surface using grinders, the built-in pre-burn function removes surface contaminants from the sample. It uses high-purity argon gas and can irradiate a spot of approximately 50μm. 【Features】 ■ Measurement of pipe ends is also possible ■ Argon gas flushing using proprietary patented technology ■ Uses high-purity argon gas ■ Multi-point analysis in narrow areas is possible (6 locations) ■ Can irradiate a spot of approximately 50μm *For more details, please refer to the PDF document or feel free to contact us.

  • 2021-08-25_17h41_32.png
  • 2021-08-25_17h41_39.png
  • 2021-08-25_17h41_47.png
  • Spectroscopic Analysis Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Uniformity of Content Testing for Tablets Using Near-Infrared Spectroscopy (NIR) [Technical Document]

Pharmaceuticals, medicines, supplements related applications: Content uniformity testing of tablets using near-infrared spectroscopy (NIR).

Near-infrared spectrometers (NIR) are considered one of the PAT (Process Analytical Technology) tools for monitoring processes due to their fast and accurate measurements. This application note demonstrates that using NIR analyzers can reduce the workload of HPLC analysis in the lab and enable near-real-time content uniformity testing during the tablet compression process. [Pharmaceuticals]

  • OMNIS_NIR_5961.jpg
  • Near-infrared spectrophotometer
  • Spectroscopic Analysis Equipment
  • Pharmaceutical materials and carriers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration