We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS ・ IPROS One of the largest technical database sites in Japan that collects information on.

column Product List and Ranking from 40 Manufacturers, Suppliers and Companies | IPROS GMS

Last Updated: Aggregation Period:Sep 02, 2026~Sep 29, 2026
This ranking is based on the number of page views on our site.

column Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 02, 2026~Sep 29, 2026
This ranking is based on the number of page views on our site.

  1. アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  2. Restek Tokyo//Testing, Analysis and Measurement
  3. 日本ウォーターズ(米国本社 Waters Corporation)  Tokyo//Testing, Analysis and Measurement
  4. 4 山善 Osaka//Machine elements and parts
  5. 5 巴製作所 本社・尼崎工場 Hyogo//Manufacturing and processing contract

column Product ranking

Last Updated: Aggregation Period:Sep 02, 2026~Sep 29, 2026
This ranking is based on the number of page views on our site.

  1. GC column "SE-30/SE-54" アジレント・テクノロジー株式会社
  2. Column "Inject Column" 山善
  3. Low-adsorption LC column MaxPeak Premier column 日本ウォーターズ(米国本社 Waters Corporation) 
  4. GC column "DB-WAX" アジレント・テクノロジー株式会社
  5. 4 Technical Data: TSKgel ODS-100V 3μm 東ソー バイオサイエンス事業部 計測分野

column Product List

181~210 item / All 210 items

Displayed results

GC column "DB-5"

Low breed! We introduce a non-polar column with a wide range of applications at high upper temperature limits!

The "DB-5" is a non-polar column made of (5% phenyl) methyl siloxane. It features a chemical bond and crosslinking type, and is capable of solvent washing. It corresponds to USP Phase G27, and we offer a wide variety of column sizes. Please feel free to contact us when you need assistance. 【Features】 ■ (5%-phenyl)-methyl polysiloxane ■ Non-polar ■ Excellent general-purpose column ■ Wide range of applications ■ Low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "HP-5"

Chemical bonding and cross-linking type, with a wide range of applications! We introduce an excellent general-purpose column!

The "HP-5" is a non-polar column made of (5%-phenyl)-methylpolysiloxane. It corresponds to USP Phase G27 and can be solvent cleaned at high upper temperature. We continue to pursue further improvements in analytical performance standards such as separation efficiency, reproducibility of retention times, and peak height ratios. Please feel free to contact us when you need assistance. 【Features】 ■ (5%-phenyl)-methylpolysiloxane ■ Non-polar ■ Excellent general-purpose column ■ Wide range of applications ■ High upper temperature *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "CP-Sil 8 CB"

It shows excellent selectivity for aromatic compounds and is a suitable column for condition testing!

The 'CP-Sil 8 CB', which uses 5% phenyl and 95% dimethyl polysiloxane as the liquid phase, is a column with slightly higher polarity than the 'CP-Sil 5 CB'. It demonstrates excellent selectivity for aromatic compounds and is suitable for condition testing. Additionally, it shows good inter-column reproducibility, high separation efficiency, and selectivity. 【Features】 ■ Uses 5% phenyl and 95% dimethyl polysiloxane as the liquid phase ■ High-efficiency and high-precision GC column ■ Offers various column sizes ■ Improves productivity with excellent reproducibility and selectivity *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-210"

Suitable for U.S. EPA Methods 8140 and 609! Chemical bonding/crosslinking type, solvent cleaning possible.

We would like to introduce our GC column "DB-210." It is equivalent to (50% trifluoropropyl) methyl polysiloxane and has high polarity. It is suitable for U.S. EPA Methods 8140 and 609 and is a chemically bonded and cross-linked type. It allows for solvent cleaning and serves as a replacement for HP-210. 【Features】 ■ (50% trifluoropropyl) methyl polysiloxane ■ High polarity ■ Suitable for U.S. EPA Methods 8140 and 609 ■ Chemically bonded and cross-linked type ■ Solvent cleaning possible ■ Replacement for HP-210 ■ Equivalent to USP Phase G6 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-1301"

Pursuing further improvement of performance standards! Alternatives to HP-1301/HP-1701.

We would like to introduce our GC column "DB-1301." It is a (6% cyanopropylphenyl) methylpolysiloxane, equivalent to USP Phase G43. It has low to medium polarity and is of the chemical bond/crosslink type. It serves as a substitute for HP-1301/HP-1701. 【Features】 ■ (6% cyanopropylphenyl) methylpolysiloxane ■ Equivalent to USP Phase G43 ■ Low to medium polarity ■ Chemical bond/crosslink type ■ Substitute for HP-1301/HP-1701 ■ Solvent-cleanable *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "SE-30/SE-54"

Highly reliable qualitative/quantitative results can be obtained! Operating temperature range is 0 to 325/350℃.

The "SE-30" is a 100% dimethyl polysiloxane column, while the "SE-54" is a (5%-phenyl) (1%-vinyl)-methyl polysiloxane column. Both columns are precisely designed to ensure a temperature operating range of 0 to 325/350°C, providing high accuracy, efficiency, and reproducibility of results. These columns can be used in established methods that require columns without cross-linked or chemically bonded polymer phases, as they are neither chemically bonded nor cross-linked. 【Features】 ■ Operating temperature range of 0 to 325/350°C ■ Precisely designed to ensure high accuracy, efficiency, and reproducibility of results ■ Neither chemically bonded nor cross-linked ■ Can be used in established methods that require columns without cross-linked or chemically bonded polymer phases *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

DB-HT SimDis Column

Introducing a column suitable for high-temperature suspected distillation! Achieving low bleed even at 430℃.

The features of the "DB-HT SimDis Column" include consistent high performance suitable for high-temperature simulated distillation (SIMDIS) with a "boiling point" phase and a highly durable stainless steel tube. This product has low bleed and a distillation range of C6 to C110 at an operating temperature range of -60 to 430°C. It also allows for solvent cleaning with chemical bonding and cross-linking types. Since it is tested based on the industry's very strict QC standards, you can always obtain highly accurate results. 【Features】 ■ 100% Dimethylpolysiloxane ■ Highly durable stainless steel tube ■ Maximum temperature: 430°C ■ Distillation range: C6 to C110+ ■ Achieves low bleed even at 430°C *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

CP-SimDist UltiMetal Column

Supports analysis up to C120 at a maximum temperature of 450℃! Achieves excellent retention time reproducibility.

The "CP-SimDist UltiMetal Column" enhances analytical performance up to C120 thanks to its robust inert UltiMetal tube. Since the inner diameter is the same as that of a fused silica (megabore) column at 0.53mm, automatic and smooth on-column injection is possible. The surface has undergone a special inert treatment, resulting in superior reproducibility of retention times compared to other high-temperature columns. 【Features】 ■ Designed to comply with ASTM D2887 and its related test methods ■ Low bleed ■ Supports analysis up to C120 at a maximum temperature of 450℃ ■ Excellent durability with UltiMetal tube ■ 0.53mm inner diameter, same as fused silica *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-Sulfur SCD"

Various custom configurations are available! Reducing lab downtime and operational costs.

The "DB-Sulfur SCD" is a column optimized for chemical luminescence sulfur detectors, featuring low bleed and minimal contamination of the SCD ceramic tube. It achieves excellent peak shapes in all GC SCD methods using dimethylpolysiloxane (PDMS) stationary phases, such as ASTM D 5623 and 5504 analyses. It enhances detector stability and reduces maintenance and associated downtime. 【Features】 ■ Improved data reliability ■ Significantly reduced bleed ■ Suitable SCD stability ■ Reduced lab downtime, maintenance, and operational costs ■ Available in various custom configurations *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Select Low Sulfur"

Highly reliable quantitative results can be obtained! Mechanical stability suppresses particle detachment.

"Select Low Sulfur" is a column designed to meet the specific needs of the petrochemical field, capable of detecting sulfur compounds in propylene at low detection limits. Due to its very high inertness to volatile reactive sulfur components, it achieves extremely low detection limits. Its unique selectivity prevents co-elution and matrix interference in propylene analysis. 【Features】 ■ The column has very high inertness, achieving good peak shapes for active compounds. ■ Low detection limits for sulfur compounds. ■ Prevents co-elution and matrix interference in propylene analysis. ■ High retention of volatile components achieved through a highly permeable PLOT stationary phase. ■ Consistent column inertness achieved through a unique QC testing procedure. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-1701P"

Designed and processed for the analysis of organochlorine pesticides! Introduction of chemical bonds and cross-linking types.

The "DB-1701P" is a low/mid-polarity GC column. It has been tested to minimize pesticide degradation and ensure low ECD bleed. It can be used as a substitute for HP-PAS1701. It features chemical bonding and cross-linking, and is capable of solvent cleaning. 【Features】 ■ Low/mid polarity ■ Substitute for HP-PAS1701 ■ Specifically designed and treated for the analysis of organic chlorine pesticides ■ Tested to minimize pesticide degradation and ensure low ECD bleed ■ Solvent cleaning available *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "VF-1701 Pesticides"

Proven performance in ECD or MS detection! Improved sensitivity achieved through ultra-low bleed.

The "VF-1701 Pesticides" is a column specifically designed for the analysis of trace pesticide residues. Our columns undergo pre-shipment testing with key pesticides, including endrin and aldrin, ensuring appropriate performance and consistency of results. Additionally, they are highly deactivated for the analysis of trace pesticides, allowing for better detection limits. 【Features】 ■ Designed specifically for the analysis of trace pesticide residues ■ Individual column tests conducted using key pesticides, including endrin and aldrin ■ Enhanced detection limits for measuring trace pesticides due to advanced deactivation ■ Proven performance with ECD or MS detection ■ Improved sensitivity achieved through ultra-low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 8 CB for Pesticides"

Excellent inertness proven by tests using DDT! Providing highly reliable data.

The "CP-Sil 8 CB for Pesticides" is a column that achieves linear column response at the femtogram level. This product is equipped with an integrated retention gap, which prevents issues caused by solvent aggregation, allowing for repeated splitless injections without degrading the phase. Furthermore, the integrated retention gap prevents leaks from connections, significantly extending the column's lifespan. 【Features】 ■ Improved productivity due to linear column response down to the femtogram level ■ Proven excellent inertness through tests using DDT, providing reliable data ■ On-column injection is possible ■ The integrated retention gap prevents issues caused by solvent aggregation, allowing for repeated splitless injections without degrading the phase *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Non-polar column "HP-PAS5"

Chemical bonding and cross-linking type! Specifically designed and processed for the analysis of organic chlorine pesticides.

The "HP-PAS5" is a non-polar column specifically designed and treated for the analysis of organochlorine pesticides. The operating temperature range is -60 to 325/350°C, and it has undergone ECD testing to minimize pesticide decomposition and achieve low ECD bleed. It features chemical bonding and cross-linking, is washable with solvents, and has been tested against strict QC industry standards, providing high reliability in the accuracy and integrity of analytical results. 【Features】 ■ Non-polar ■ Specifically designed and treated for the analysis of organochlorine pesticides ■ ECD testing ensures minimal pesticide decomposition and low ECD bleed ■ Chemical bonding and cross-linking type ■ Washable with solvents *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Rapid-MS"

Outstanding sensitivity following the FactorFour VF-5ms! Compatible with any manufacturer's GC!

"Rapid-MS" is a capillary column that performs GC/MS analysis at speeds approximately 3 to 5 times faster under temperature ramp conditions and about 10 times faster under isothermal conditions. To accommodate a wide range of analyses, it is available with film thicknesses from 0.1 to 1.0 μm, while also improving the S/N ratio by about 3 times. It can be connected to any manufacturer's GC. 【Features】 ■ Maximizes productivity with rapid analysis ■ Excellent sensitivity following the FactorFour VF-5ms ■ Compatible with any manufacturer's GC (used for GC/MS) *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "VF-17ms for PAH"

The confirmation column of the EPA method, which maximizes the reliability of analysis results, is suitable!

The "VF-17ms for PAH" is a column that can separate polycyclic aromatic hydrocarbons, which are regulated by the EU and EPA, in less than 30 minutes. With inertization technology, it improves data quality and maximizes the reliability of analytical results, making it suitable as a confirmation column for EPA methods. It is a chemical bond/crosslink type that can be cleaned with solvents, helping to reduce column replacement costs. 【Features】 ■ Capable of separating polycyclic aromatic hydrocarbons regulated by the EU and EPA in less than 30 minutes ■ Improves data quality through inertization technology ■ Highly suitable as a confirmation column for EPA methods, maximizing the reliability of analytical results ■ A chemical bond/crosslink type that can be cleaned with solvents, helping to reduce column replacement costs ■ Subjected to tests based on very strict QC specifications in the industry regarding column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 88 for Dioxins"

A leak-free integrated retention gap! Extends column life when using splitless injection.

"CP-Sil 88 for Dioxins" is an ultra-high polarity column specifically designed for the separation of dioxins and dibenzofurans. It features an integrated retention gap, which prevents issues caused by solvent condensation and allows for repeated splitless injection without degrading the stationary phase. Additionally, the column's lifespan is extended, and data quality is significantly improved. 【Features】 ■ High-polarity stationary phase with selectivity specialized for the separation of dioxins and dibenzofurans ■ Integrated retention gap with no leaks, extending column lifespan during splitless injection ■ Capable of measuring low concentrations of 2,3,7,8-TCDD ■ Columns with a thin film configuration and a temperature program limit of 270°C are also available *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraPLOT Q-HT"

The reproducibility of retention time is stable! Water elutes with a sharp peak, improving quantitative accuracy.

"PoraPLOT Q-HT" is a column for the analysis of volatile compounds. The maximum operating temperature has been expanded to 290°C. It can be used for applications involving halogenated compounds, hydrocarbons C1 to C6, organic solvents, and more. Please feel free to consult us when you need assistance. 【Features】 ■ Suitable for the analysis of a wide range of volatile compounds from high polarity to non-polar ■ Water elutes with sharp peaks, improving quantification accuracy ■ Stable reproducibility of retention times *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT Q"

Durable and recommended "Q" column! Good separation can be achieved in various applications.

"HP-PLOT Q" is a column made of bonded polystyrene-divinylbenzene. It can be used at a temperature limit of -60 to 270/290°C. Good separations are achieved in applications involving hydrocarbons, CO2, methane, air/CO, water, polar solvents, sulfur compounds, and more. It provides high separation in a shorter time compared to traditional packed columns. Please feel free to consult us when you need assistance. 【Features】 ■ Bonded polystyrene-divinylbenzene (DVB) column ■ A PLOT column with intermediate polarity between Porapak-Q and Porapak-N ■ A PLOT column that serves as an alternative to packed columns ■ High separation in a shorter time than traditional packed columns ■ Requires a minimum of 1 hour for conditioning *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-Q"

Separation of ethane, ethylene, and acetylene! Intermediate polarity PLOT column of Porapak-Q and Porapak-N.

The "GS-Q" is a column suitable for the analysis of gases containing fluorinated compounds and sulfur compounds. (Excluding SO2) It can be used within a temperature range of -60 to 250°C. The minimum conditioning time required is 1 hour, and it separates ethane, ethylene, and acetylene. Please feel free to contact us when you need assistance. 【Features】 ■ Porous divinylbenzene homopolymer ■ A PLOT column with intermediate polarity between Porapak-Q and Porapak-N ■ Separates ethane, ethylene, and acetylene ■ Not suitable for quantifying polar compounds ■ Minimum conditioning time: 1 hour *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT U"

It can be used in a wide range of applications such as CO2, methane, air/CO, water, solvents, alcohols, and ketones.

"HP-PLOT U" is a column with a stationary phase bonded with divinylbenzene/dimethacrylate ethylene glycol. It can be used in a wide range of applications including C1 to C7 hydrocarbons, CO2, methane, air/CO, water, dimethacrylate glycol-containing oxygen compounds, amines, solvents, alcohols, ketones, and aldehydes. Due to its high polarity, it has different selectivity and shows good peak shapes, especially for water-containing substances. 【Features】 ■ Bonded divinylbenzene/dimethacrylate ethylene glycol ■ Higher polarity than HP-PLOT Q ■ Suitable for C1 to C7 hydrocarbons, CO2, methane, air/CO, water, oxygen-containing compounds, amines, solvents, alcohols, ketones, and aldehydes ■ Provides high separation in a shorter time compared to traditional packed columns *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraPLOT U"

Prevent particle detachment as much as possible! Elute volatile compounds from high polarity to non-polar at symmetrical peaks.

"PoraPLOT U" is an analytical column for halogenated compounds, hydrocarbons, and ketones. It elutes high-polarity volatile compounds with well-symmetrical peaks. Water in the sample does not affect the retention time and does not cause broadening. Please feel free to consult us when needed. 【Features】 ■ Elutes volatile compounds from high polarity to non-polar with symmetrical peaks ■ Minimizes particle shedding *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-Alumina KCl"

Special deactivation! A versatile column suitable for the analysis of light hydrocarbons of C1 to C8 hydrocarbon isomers.

"GS-Alumina KCl" is a column that has undergone special inertization and can be rapidly regenerated. This product, which completely adsorbs water, can be regenerated at 200°C in less than 7 hours. It is also suitable for the separation of cyclopropane from propylene and is recommended as an alternative to sodium sulfide alumina due to its regenerability. 【Features】 ■ High polarity alumina phase ■ Special inertization ■ Faster, more efficient, and highly sensitive compared to equivalent packed columns ■ Minimal conditioning required ■ Recommended as an alternative to sodium sulfide alumina due to its regenerability *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT Al2O3 S"

Ideal for accurate quantitative analysis of diene! Separating propadiene and butadiene from the flow of ethylene and propylene.

The "HP-PLOT Al2O3 S" is a column that can separate gases at room temperature. It is suitable for KCI-treated inactive alumina. Different inert treatments have been applied to Al2O3, providing good resolution in hydrocarbon isomer analysis. We offer products with film thicknesses of 5.00, 8.00, and 15.00 μm. Please feel free to consult us when you need assistance. 【Features】 ■ Inactivated with KCl ■ Lower retention for olefins compared to corresponding paraffins ■ A standard column suitable for the analysis of lower hydrocarbons in C1 to C8 hydrocarbon isomers ■ Particularly suitable for accurate quantitative analysis of dienes, especially separating propyne and butadiene from the flow of ethylene and propylene *For more details, please refer to the PDF materials or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-Alumina"

High-speed, efficient, and highly sensitive! Suitable for the separation of propylene from cyclopropane.

"GS-Alumina" is a general-purpose column suitable for the analysis of light hydrocarbons in C1 to C8 hydrocarbon isomers. It is fast, efficient, and highly sensitive. Due to its regenerability, it is recommended as an alternative to sodium sulfide alumina. It is also suitable for the separation of propylene from cyclopropane. Please feel free to consult us when needed. 【Features】 ■ High polarity alumina phase ■ Special inertization ■ Fast, efficient, and highly sensitive ■ Separation of C1 to C4 saturated and unsaturated hydrocarbons ■ General-purpose column suitable for the analysis of light hydrocarbons in C1 to C8 hydrocarbon isomers *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-GasPro"

Separation of CO and CO2 in a single column! Suitable for the analysis of light hydrocarbons and sulfur gases.

The "GS-GasPro" is a column that can be used at temperature limits of -80 to 260/300°C. With its unique bonded silica PLOT column technology, it offers retention stability that is not affected by water. Agilent's commitment to reliability and reproducibility in its products supports the improvement of quality levels demanded by chromatography experts. Please feel free to consult us when needed. 【Features】 ■ Unique bonded silica PLOT column technology ■ Suitable for analysis of light hydrocarbons and sulfur gases ■ Retention stability unaffected by water ■ Separates CO and CO2 with a single column ■ Ideal PLOT column for GC/MS - does not generate particles *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-SilicaPLOT"

Separation of cyclopropane and propylene! Analysis of carbon dioxide and sulfur gas at ppm levels.

"CP-SilicaPLOT" is a column that provides high separation and fast analysis. It is ideal for the analysis of COS, CFC, hydrocarbons, propylene, and sulfur gases in ethylene. It can analyze carbon dioxide and sulfur gases at the ppm level and separate cyclopropane and propylene. Please feel free to contact us when you need assistance. 【Features】 ■ Retention time is unaffected by water ■ Analyzes carbon dioxide and sulfur gases at ppm levels ■ Separates cyclopropane and propylene *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CarboBOND"

No particle trap needed with chemical bonding type! Stability and robustness enhance the reproducibility of results.

"CarboBOND" is a column compliant with ASTM D 2505. It is suitable for the analysis of hydrocarbons in ethylene, gases in ethylene and propylene, He, Xe, CO, Ne, CH4, CO2, O2/Ar, N2, and Kr. High-boiling compounds can also be eluted in a short time, and since it is not affected by water, the reproducibility of retention times is excellent. 【Features】 ■ Column compliant with ASTM D 2505 ■ Maximum operating temperature extended to 300°C ■ Stability and robustness enhance the reproducibility of results ■ Chemical bond type, no particle trap required *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Small Sampling Pump L-5P

It is ideal for sampling asbestos and organic solvents. The flow rate range is from 800cc to 5L/min. It covers a wide range with one unit.

This is a compact pump that is ideal for sampling substances such as asbestos and organic solvents. The flow rate range is from 800cc to 5L/min, allowing it to cover a wide range with just one unit. Additionally, with optional parts, it is also possible to perform low-flow sampling at 5CC/min. The body is made of reinforced plastic, making it durable. It can operate even under high back pressure. Furthermore, there are models available that can be equipped with a gas back on the pump outlet side. The pump comes standard with a nickel-hydrogen battery, a battery charger (AC100V), a ruler hose adapter, a clip for shirts, and vinyl hoses. With its wide flow rate range, one unit can cover the capacity of two or three units from other manufacturers.

  • Other environmental analysis equipment
  • Other environmental analysis equipment
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

KeyManager-NX

Reduction of key management burden / Improvement of information and safety management / Measures for personal information protection law

【Features】 ● Keys cannot be removed without authentication via non-contact IC cards or passwords. ● Settings for each employee can be configured to allow or disallow key usage. ● A history of who took out and returned the keys, and when, can be saved. ● There are two types of systems: USB memory version and LAN version, allowing for master information updates and history management.

  • Encryption and authentication
  • Entrance and exit control system
  • Personal authentication
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration