We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for inspection.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

inspection Product List and Ranking from 39 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

inspection Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

  1. つくば食品評価センター プリマハムグループ Ibaraki//Testing, Analysis and Measurement
  2. メトロームジャパン 本社 Tokyo//Testing, Analysis and Measurement
  3. 富士精工 Aichi//Machine elements and parts
  4. 4 アヅマックス Tokyo//Pharmaceuticals and Biotechnology
  5. 5 null/null

inspection Product ranking

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

  1. For allergen wipe tests! "Allergen Eye Quick" つくば食品評価センター プリマハムグループ
  2. Inspection and processing jig "mandrel" 富士精工
  3. Near-infrared analyzer Polyvinyl alcohol saponification degree [Technical Data] メトロームジャパン 本社
  4. L-Glutamic Acid Test Paper - Simple Quantification Kit for Glutamic Acid Concentration つくば食品評価センター プリマハムグループ
  5. 4 Allergen Eye Wipe Test Kit 'Walnut/Almond' つくば食品評価センター プリマハムグループ

inspection Product List

46~60 item / All 89 items

Displayed results

Inspection and processing jig "mandrel"

It is ideal for chucks during the measurement/processing of ring-shaped products.

Two types of lineup: hydraulic type / slide type ▶ Easy for anyone, reduces centering work by 95% ▶ Ensures high precision with a low-cost mechanism (runout precision below 5μm) ▶ Common body compatible with a variety of products We will set it up according to the workpiece shape, usage environment, and customer requests. We offer a slide key type that eliminates the need to change collets for each workpiece, and a hydraulic type that accommodates a wide range of workpiece shapes and applications. As a stable high-precision clamping tool that minimizes individual differences with easy operation, we achieve "easy," "high precision," and "flexibility" simultaneously.

  • Chuck

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Automated Quality Management 3D Scanning Solution 'R-Series'

Achieving efficient quality control through inspection automation!

The R-Serie 3D scanning solution, designed for automated quality management applications, enables high-precision and rapid measurement of part shapes and dimensions. By building inspection systems with the booth-packaged "CUBE-R" and the highly customizable "MetraSCAN 3D-R," efficient quality management is achieved. 【Features】 ■ High precision suitable for manufacturing environments ■ Blue laser technology optimal for glossy and reflective surfaces ■ Compliance with VDI/VDE 2634 Part 3 standards in ISO 17025 accredited labs ■ Ideal for various part sizes and shapes ■ Custom integration available

  • スライド2.JPG
  • スライド3.JPG
  • スライド4.JPG
  • 3D measuring device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ATP swab test kit (manufactured by Hygiena) from Azumax.

Get the factory hygiene management tools from Azumax Corporation! Hygiena ATP swab testing kit!!

"Is it clean?" "Is it sanitized?" This is a rapid ATP hygiene test required for hygiene management efforts in various places. The Hygiena ATP test kit is easy to use for anyone, anytime. The "ATP swab test," which provides results in just a few seconds, is a rapid hygiene testing tool for assessing cleanliness and hygiene status after cleaning. It is expanding its use not only in the food industry but also in the medical field, where hygiene management is of high importance, and other industries.

  • Other inspection equipment and devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Uniformity of Content Testing for Tablets Using Near Infrared Analysis (NIR) [Technical Document]

Pharmaceutical-related applications: Uniformity testing of tablet content using Near Infrared Spectroscopy (NIR).

Near-infrared analyzers (NIR) are considered one of the PAT (Process Analytical Technology) tools for monitoring processes due to their fast and accurate measurements. This application note demonstrates that using NIR analyzers can reduce the workload of HPLC analysis in the lab and enable content uniformity testing at near real-time speeds during the tablet compression process. [Pharmaceuticals]

  • OMNIS_5961-withpeople2-X3000.jpg
  • OMNIS-NIR-GIF--1-X2000.gif
  • Near-infrared spectrophotometer
  • Ingredient analysis
  • Spectroscopic Analysis Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Technical Document] Near-Infrared Analysis of Methane Potential in Biogas Production

Application 3: Short-term measurement of methane potential (BMP) in biogas production using near-infrared spectroscopy (NIRS).

This application note demonstrates that by using near-infrared spectroscopy (NIRS) with the DS2500 analyzer from Metrohm and the calibration model FlashBMP (from Ondalys), the analysis time for methane production potential (BMP) of various substrates obtained from anaerobic fermentation can be shortened, thereby improving efficiency. In contrast to conventional analytical methods, near-infrared analyzers (NIRS) can analyze BMP values within minutes, making it an analytical technique for optimizing the methane fermentation process. 【Fuel, Energy, Biofuels】

  • OMNIS_NIR_20240306_FV_04-cut.jpg
  • Spectroscopic Analysis Equipment
  • Biogas
  • Near-infrared spectrophotometer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Near-infrared analyzer: Comparison of dispersed and Fourier transform technologies [Technical Document]

Explaining the similarities and differences between decentralized analyzers and Fourier transform (FT) analyzers in near-infrared analysis (NIR).

Near-infrared spectroscopy (NIRS) is an analytical technique widely used for quantitative analysis of raw material substances in research and industrial applications. Metrom's white paper clarifies the similarities and differences between decentralized analyzers and Fourier transform (FT) analyzers in near-infrared analysis devices.

  • OMNIS_NIR_20240306_FV_04-cut.jpg
  • Spectroscopic Analysis Equipment
  • Near-infrared spectrophotometer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Efficiency Improvement of Polyurethane Production Line Using NIR and Raman [Technical Document]

Optimization of the polyurethane manufacturing line using a combination of near-infrared spectroscopy (NIR) and Raman spectroscopy.

Significantly reduce manufacturing costs by using near-infrared analyzers (NIR) and Raman spectrometers for reaction control and quality management in the production process of polyols and isocyanates, which are intermediates in polyurethane manufacturing!

  • OMNIS-NIR-GIF--1-X2000.gif
  • MIRA-P-GIF-1.gif
  • Analytical Equipment and Devices
  • plastic
  • Spectroscopic Analysis Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Quality Control of Polyethylene (PE) Using Near-Infrared Analysis Equipment [Technical Document]

With a near-infrared analyzer (NIR), you can easily and reliably measure polyethylene density in under one minute!

【Near Infrared Analyzer Technical Data 10 Petrochemicals】 Measuring the density of polyethylene (PE) (ASTM D792) is challenging due to the difficulty in achieving reproducible results using standard measurement procedures. This application note demonstrates the determination of the specific gravity of PE by measurement with a near-infrared analyzer. By using a visible-near-infrared analytical method that does not require sample pretreatment or chemical reagents, it is possible to analyze large heterogeneous samples in under one minute.

  • OMNIS_NIR_20240306_FV_04-cut.jpg
  • OMNIS_NIR_naname_5895s.jpg
  • Spectroscopic Analysis Equipment
  • Near-infrared spectrophotometer
  • plastic

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Simultaneous quantitative analysis of four components of PET resin using near-infrared analyzer [Technical Document]

Quantification of diethylene glycol, isophthalic acid, intrinsic viscosity, and acid value in PET resin, a type of polyester, using near-infrared spectroscopy.

This document explains the quantitative analysis of diethylene glycol (DEG), isophthalic acid (IPA), intrinsic viscosity (IV), and acid value (TAN) contained in polyethylene terephthalate (PET), a type of polyester. Traditional chemical analysis using reagents requires time to obtain results and relies on the skill of the operator, whereas near-infrared analysis allows for simple and rapid measurements without the need for special skills.

  • OMNIS_NIR_20240306_FV_04-cut.jpg
  • plastic
  • Other polymer materials
  • Spectroscopic Analysis Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Quality Control Analysis of Polyols Using Near-Infrared Analyzers [Technical Document]

Simultaneous measurement of acid value, hydroxyl value, and moisture content in polyols, which are the raw materials for polyurethane, using near-infrared analysis.

Near Infrared Analyzer Technical Data 11 Petrochemical Resin Polyurethane Resin By using a near-infrared analyzer (NIR), analysis can be performed in its original form without sample pretreatment. Due to its multi-component capability, NIR can simultaneously measure multiple quality parameters in a very short time. As a result, it significantly reduces the time compared to conventional analysis methods. Furthermore, this analytical method allows for analysis without the use of solvents or reagents, which can greatly reduce the operating costs of QC labs.

  • OMNIS_NIR_20240306_FV_04-cut.jpg
  • plastic
  • Spectroscopic Analysis Equipment
  • Other polymer materials

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Technical Data: Quality Control of Pyrolysis Gasoline Using Near-Infrared Analysis.

With a near-infrared analyzer, the diene value (anhydrous maleic acid value) of pyrolysis gasoline (pygas) can be measured in under one minute!

Near-Infrared Analyzer Technical Data 16 Petroleum Gasoline Fuel Pyrolysis Gasoline Pyrolysis gasoline (Pygas) is a byproduct of ethylene production and is unsuitable as motor fuel due to the presence of unwanted conjugated diolefins. To eliminate this drawback, it is necessary to reduce the olefin content to below 2 mg/g using a Selective Hydrogenation Unit (SHU). The diene value (or Maleic Anhydride Value (MAV)) is typically determined by wet chemical analysis through the Diels-Alder reaction (UOP326-17). This wet chemical analysis method requires trained analysts to perform it over several hours. Near-Infrared Spectroscopy (NIRS) contrasts with this chemical analysis method and can be applied as a cost-effective, rapid analytical technique for determining the diene value in pyrolysis gasoline.

  • OMNIS_NIR_20240306_FV_04-cut.jpg
  • Spectroscopic Analysis Equipment
  • Demand Monitoring

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Rapid measurement and significant cost reduction with near-infrared analyzers (NIR) [Technical Document]

Using near-infrared analyzers (near-infrared spectrometers) for quality control can reduce costs by over 90%!

Near Infrared Analyzer (Near Infrared Spectrometer) Technical Data Quality Management (Contents of the White Paper) - Mechanism of NIR - Advantages of NIR compared to conventional methods - Reasons why 10-30% of revenue is lost due to defects in QA/QC - Applications of NIR in the petrochemical, polymer, and chemical industries

  • OMNIS_NIR_20240306_FV_04-cut.jpg
  • Other inspection equipment and devices
  • Near-infrared spectrophotometer
  • Food/beverage component analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Analysis of Petroleum Products Using Near-Infrared Analyzers [Technical Document]

Technical document introducing the analysis of cetane index, total acid number (TAN), bromine number, aromatics, and sulfur in petroleum products using near-infrared analyzers.

Near Infrared Analyzer Technical Data 19 Petroleum This application note describes the measurement of cetane index, aromatic content, bromine number, TAN (Total Acid Number), and sulfur content of various petroleum products.

  • OMNIS_NIR_20240306_FV_04-cut.jpg
  • Near-infrared spectrophotometer
  • Rubber
  • Spectroscopic Analysis Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Analysis of Roasted Coffee Using Near Infrared Spectroscopy (NIR) [Technical Document]

Rapid measurement of caffeine, water activity, and moisture using a near-infrared analyzer.

【Near Infrared Analyzer Technical Data 22 Food and Beverages】 Near Infrared Spectroscopy (NIRS) allows for the rapid analysis of caffeine, water activity, and moisture in roasted coffee beans and ground coffee without the use of any chemicals. Analysis using NIRS requires no sample pretreatment and is easy to operate. The analytical device introduced in this article can be placed near the roaster or in a quality control lab for analysis.

  • OMNIS-NIR-GIF--1-X2000.gif
  • Near-infrared spectrophotometer
  • Food/beverage component analyzer
  • Spectroscopic Analysis Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Technical Documentation on Bris (Sugar Content) in Juice Using Near Infrared Analyzer (NIR)

Simultaneous measurement of sugar content (Brix), glucose, fructose, and sucrose in fruit juice using near-infrared analyzer.

【Near Infrared Analyzer Technical Data 24 Food and Beverages】 When considering root juice as a product, the sugar content in the product is a very important parameter because it is a sweet beverage. Among these, the contents of fructose, glucose, and sucrose are considered very important sugars for quality control. Traditionally, to measure these sugars in fruit juice through laboratory analysis, liquid chromatography is used along with refractive index measurement. When there are multiple analytical methods like this, each analysis requires time and expertise, as well as the need for different analytical instruments. Near Infrared Spectroscopy (NIRS) is an analytical technique that can simultaneously measure glucose, fructose, sucrose, and Brix in fruit juice in under one minute. Furthermore, it does not require chemical reagents, and no sample pretreatment is necessary.

  • OMNIS-NIR-GIF--1-X2000.gif
  • Near-infrared spectrophotometer
  • Spectroscopic Analysis Equipment
  • Food/beverage component analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration