We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Biosensors.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Biosensors Product List and Ranking from 5 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

Biosensors Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

  1. ザルトリウス・ジャパン Tokyo//Testing, Analysis and Measurement
  2. 山形シルクスクリーン研究所 東京営業所 Tokyo//others
  3. シーアンドアイ Ibaraki//others
  4. セラニーズエレクトロニクスマテリアル Kanagawa//Chemical
  5. Oji Group Functional Materials Company Tokyo//Paper and pulp

Biosensors Product ranking

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

  1. Application Note: Octet AAVX Biosensor ザルトリウス・ジャパン
  2. Waveguide mode biosensor technology シーアンドアイ
  3. Micromax Biosensor セラニーズエレクトロニクスマテリアル
  4. Biosensor 山形シルクスクリーン研究所 東京営業所
  5. BODs biosensor Oji Group Functional Materials Company

Biosensors Product List

1~5 item / All 5 items

Displayed results

Application Note: Octet AAVX Biosensor

Rapid and direct quantification of AAV capsids! Introducing the main features and benefits.

This document presents the workflow and data for quantifying multiple AAV serotypes using the Octet AAVX biosensor on the Octet BioLayer Interferometry (BLI) label-free detection platform, facilitated by a simple direct quantification assay design. It also describes the main features and advantages of the AAVX biosensor. We encourage you to read this as a reference for product introduction. [Contents (excerpt)] ■ Summary ■ Introduction ■ Reagents and Testing Procedures ■ Matrix Interference Testing ■ Correlation between Octet AAVX Assay and ELISA *For more details, please refer to the PDF document or feel free to contact us.

  • Other bio-related products and services
  • Other analytical and testing equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Waveguide mode biosensor technology

Simultaneous measurement of 4 samples enables bulk diagnosis of multiple items and simple quantification!

The waveguide mode biosensor technology is a new ultra-high sensitivity technology in a mobile size. Thanks to the adoption of a newly developed optical engine, we have achieved a 75% reduction in size. In addition to being a waveguide mode sensor, it can also be used as a 4-channel spectral spectrometer. It can accommodate testing items commonly performed in medical institutions, such as influenza and endotoxins. 【Features】 ■ High sensitivity + easy operation allows for immediate diagnosis results ■ High performance condensed into a mobile size ■ Usable in various applications and locations, including medical institutions, public health centers, and water quality management *For more details, please refer to the PDF document or feel free to contact us.

  • Other bio-related products and services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Micromax Biosensor

Electrode systems for biosensors such as blood glucose levels, blood coagulation test strips, and ECG!

We would like to introduce our healthcare and medical products. Silver/silver chloride and carbon inks are designed for high-stability electrode system applications in clinical settings, such as blood glucose and blood coagulation test strips. The "Silver/Silver Chloride Paste Micromax 5881" has been developed for screen printing on polyester film. It is suitable for electrodes of electrochemical sensors and reference electrodes. We also handle stretchable wearable grades, which are utilized in wearable sensors and electrode pads for medical sensors and low-frequency therapeutic devices. Additionally, low-temperature curing gold ink has been developed for high-inert surface electrodes for immunoassays and blood gas sensors. Please feel free to contact us if you have any inquiries. 【Product Lineup】 ■ Silver, silver/silver chloride, and carbon inks ■ Low-temperature curing gold ink ■ High-activity platinum and platinum-added carbon inks 【Applications】 ■ Silver/silver chloride paste for biosensors ■ Glucose testing and monitoring ■ Sensors for wearable/smart clothing ■ Electrodes for healthcare devices *For more details, please refer to the PDF document or feel free to contact us.

  • Other electronic parts

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Biosensor

We are engaged in the printing, processing, and cleaning of biosensors (carbon sensors) that measure various information such as blood and more.

No catalog is specifically prepared. For detailed inquiries, please contact our company directly.

  • others
  • Image Processing Equipment
  • Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

BODs biosensor

Enhanced features and excellent measurement accuracy focused on continuous monitoring operation <BODs biosensor>

- Reduction of maintenance burden The maintenance cycle is long and membrane replacement is easy due to the use of antibacterial tubes and antimicrobial agents. - Microbial immobilization kit We have prepared an immobilization kit that allows for easy immobilization of activated sludge and various cells. It can be applied not only for detecting organic pollution but also for detecting inhibitory components. - Configuration suitable for continuous monitoring operation Equipped with high-precision electronic cooling and heating control, and automatic detection of pipe blockage using pressure sensors, it supports stable automatic operation.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration