1~45 item / All 101 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us OnlineBefore making an inquiry
Download PDF1~45 item / All 101 items
■ Welding Fume Measurement Measurement of welding fume concentration through personal exposure assessment in indoor workplaces such as arc welding of metals. Measurement period: Conducted once between April 1, 2021, and March 31, 2022. ■ Basic Manganese Oxide Measurement Basic manganese has been classified as a Type 2 specified chemical substance, and work environment measurements are required in indoor workplaces (such as battery factories) where manganese and similar materials are manufactured or handled. Measurement frequency: Conducted once every six months. Our company conducts various work environment measurements based on the Labor Safety and Health Act by certified work environment measurement specialists. Please feel free to consult us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur company allows you to simply send the samples you wish to analyze by mail, making it possible to conduct investigations and analyses. Since there is no need for a service technician to visit the site, you can reduce labor and transportation costs, making it easy to carry out investigations and analyses. (Includes sampling kit and manual) You can also download a guidebook compiled by our company, which has 50 years of experience as an analytical institution, detailing various inspection items and standard values based on applicable laws! We provide detailed explanations of water quality standard values for various uses of water, such as drinking water and utility water, as well as guideline values for volatile organic compounds (VOCs) in relation to sick house measures. 【Products available for analysis service by mail】 ■ Pipe inspection (deterioration diagnosis) ■ Foreign substance inspection ■ Sick house measurement ■ PCB analysis ■ Legionella measures for cooling towers and bathtubs *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur company offers a service for "PCB Waste Investigation." The investigation targets include transformers, capacitors, ballasts, coatings, and capacitors within elevator and pump control panels. Please leave the determination of PCB content in insulating oil and PCB contamination, as well as the handling of sample kit shipments, to us. 【Investigation Targets】 ■ Transformers and capacitors (electrical equipment manufactured from 1953 to 1990) ■ Ballasts (buildings constructed until March 1977) ■ Coatings (works using chlorinated rubber-based paint manufactured from 1966 to 1974) ■ Construction sealants (polysulfide-based sealants for buildings started between 1958 and 1972) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"Online Lab e-mizu" is a service that allows you to use various inspections based on legal regulations, starting with water quality testing, online. ■ Trace PCB analysis is also available PCB waste must be disposed of by the end of March 2027. Please hurry with your investigation! ☆ We are giving away a guidebook on inspection items and standard values based on various legal regulations! ☆ 【Inspection Items】 - Drinking water, hot water - Utility water, bathtub water, pool water - Cooling water, warm water, make-up water - Legionella bacteria - Wastewater - Mineral water, water for food production - Sick house measurement - Trace PCB - Asbestos - Foreign substance inspection * For more details, please visit the dedicated site or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur company offers a "Piping Inspection" service. To continuously use the "piping," which is the blood vessel of a building, it is important to conduct regular diagnostics and prevent troubles before they occur. 【Are there any signs that could lead to such troubles?】 ■ The building is over 15 years old ■ Poor water flow ■ Unpleasant odors or unusual sounds coming from the pipes ■ There have been past leaks in the system We check the condition of the water supply pipes, hot water pipes, and drainage pipes, and calculate their remaining lifespan. (Non-destructive and continuous water work is possible.) Furthermore, we also conduct pipe inspections and leak cause investigations on pipes that have been removed during renovations or leak repairs. Additionally, we provide maintenance and inspection services for exterior structures. We can resolve sediment blockages in drainage pits and pipes with high-pressure washing, and we also offer repair work for cracks! Please feel free to consult us when needed. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"Online Lab e-mizu" is a service that allows you to conveniently use various inspections based on different regulations, including water quality testing, anytime, anywhere, and by anyone. You can collect samples at your preferred time, reducing the hassle of scheduling. 【Features】 ■ Easy online ordering for inspections ■ Request various inspection services 24/7 ■ Quickly access inspection results online ■ Easy management of past inspection records 【Inspection Items】 - Drinking water, hot water - Miscellaneous water, bathtub water, pool water - Cooling water, warm water, make-up water - Legionella bacteria - Wastewater - Mineral water, water for food production - Sick house measurement - Trace PCB - Asbestos - Foreign substance inspection *For more details, please visit the dedicated website or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe emphasize a scientific approach to "water" and "air," analyzing and measuring the causes of "invisible" troubles into "visible forms" based on high-precision analytical data. To achieve this, it is essential to not only introduce various equipment but also to enhance the skills and know-how of our staff, as well as to establish an appropriate testing environment. In June 2011, our company relocated the existing testing room due to the expansion of our office building. We have introduced new equipment and transformed into a new testing room, establishing a robust system. [Equipment Owned] ■ High-Performance Liquid Chromatography-Mass Spectrometry ■ Gas Chromatography-Mass Spectrometry ■ Luminescence Spectrometry Mass Spectrometry ■ Ion Chromatography (IC) ■ Scanning Electron Microscope (SEM-EDX) ■ X-ray Diffraction Analysis Equipment *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWater-related troubles can significantly impact our lives by harming health and the environment, as well as causing failures in air conditioning systems. Our company aims to prevent such troubles before they occur and quickly investigate the cause if a problem arises. As a team of professionals dedicated to resolving issues, we conduct thorough water quality inspections carried out by specialized staff who possess both scientific knowledge and extensive experience. 【Inspection Items】 ■ Drinking Water Quality Inspection ■ Hot Water Quality Inspection ■ Equipment Water Quality Inspection ■ Wastewater Quality Inspection ■ Hot Spring Component Analysis ■ Other Inspections *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is an introduction to a case where iron exceeding the standard value was detected in drinking water just before the completion of a new hospital construction project. One example of detecting iron is corrosion of steel pipes. However, this is unlikely in a new construction site, so an investigation of the water supply system revealed that there was a mistake in connecting the water supply pipes and the utility water pipes. Additionally, our company has also identified foreign substances using advanced equipment and a rich database. [Overview] ■ Issue - Detection of iron exceeding the standard value in drinking water just before the completion of new construction ■ Solution - Conducted an investigation of the water supply system - Determined that there was a mistake in connecting the water supply pipes and the utility water pipes [Be cautious of such troubles at new construction sites!] ■ Water may stagnate in the pipes for a long time, leading to the possibility of general bacteria and TOC (total organic carbon) exceeding standard values ■ If the water source is well water, components from the soil may leach out, causing iron, manganese, and fungi to exceed standard values.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt the university hospital, the hot water supply pipes (copper pipes) frequently developed holes, leading to constant repairs. Inspection results confirmed copper leaching, and it was determined that the high levels of free carbonic acid in the well water used for make-up water—ten times higher than in tap water—were the cause. Free carbonic acid is highly corrosive to copper, so as a corrosion prevention measure, a drinking water rust inhibitor was applied to resolve the issue. 【Overview】 ■Problem - Frequent holes in the hot water supply pipes (copper pipes) leading to constant repairs. ■Solution - Applied a drinking water rust inhibitor as a corrosion prevention measure. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDuring the regular inspection of the facility's water management items, an anomaly was detected. The results of the cold and hot water quality tests showed that the pH value decreased from "7.5→7.0→6.5" over a certain period, and further analysis detected fluoride. It was determined that there was a possibility of refrigerant (freon) contamination, and upon inspecting the equipment, it was found that there was a refrigerant gas leak from the copper tube inside the freezer. [Summary] ■ Issues - An anomaly was detected in the facility's water management items. ■ Solutions - Equipment inspection was conducted. - A refrigerant gas leak from the copper tube inside the freezer was identified. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is an introduction to a case where Legionella bacteria were detected in a cooling water system. Biofilm was found in the copper pipes of the heat exchanger, from which more than 5000 CFU/100mℓ (the standard value is 100 CFU/100mℓ) of Legionella bacteria was detected. As a countermeasure, the cooling water system was chemically cleaned, which completely removed the bacteria. 【Overview】 ■Issue - Detection of Legionella bacteria in the cooling water system ■Solution - Use of comprehensive water treatment agents - Regular cleaning of cooling towers and piping *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWater was dripping from the ceiling in the building, and we were troubled because we couldn't identify the leak location. As a result of the inspection, high concentrations of anionic surfactants, which are components of detergents, and the amount of hexane extract, indicating oil content, were detected, leading to the conclusion that the leaked water was from kitchen drainage. By investigating "what kind of water is leaking," we were able to accurately pinpoint the leak location. Water also has its own characteristics, and the type of water can be identified from its components. 【Overview】 ■Issue - Water is dripping from the ceiling, but the leak location is unknown. ■Solution - High concentrations of hexane extract, a detergent component, were detected. - We were able to accurately identify the leak location. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationMethane gas, which poses a risk of explosion due to its flammability, has been detected above the standard level. At a certain hot spring facility, we conducted an analysis of the hot spring components and measured methane gas. Our company thoroughly understands the equipment and systems from the "source area → storage tank → terminal in the bathing area" and conducts measurements to confirm safety, proposing improvements as necessary. It is important to conduct inspections based on a correct understanding of the condition of the equipment. 【Overview】 ■ Issues - Methane gas, which poses a risk of explosion, has been detected above the standard level at the hot spring facility. ■ Solutions - Conducted analysis of hot spring components and measurement of methane gas. - Proposed improvements as necessary after confirming safety. We also conduct water quality testing utilizing our extensive knowledge and experience for various purposes, including non-potable water such as irrigation, landscaping water, and toilet flushing water, analysis of commercially available mineral water, testing of various waters used in production processes, water quality testing of seas and rivers for environmental assessments related to infrastructure construction, and water quality testing for agricultural water. ● Pool water quality testing ● Non-potable water quality testing ● Water quality testing under the Food Sanitation Act ● Analysis of mineral water components ● Testing of agricultural water ● Water quality testing of seas and rivers for environmental assessments ● Inspections in accordance with the Soil Contamination Countermeasures Act, etc.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur company conducts thorough precision management from sample collection to storage, analysis operations, and result aggregation. We repeatedly analyze samples not only when there are variations or biases in the values but also when the water quality is within standard values but lacks balance, until the reasons are clarified. Additionally, we have established a system to deliver test results to our customers promptly. We are also open to consultations regarding emergencies, so please feel free to reach out to us. 【Licenses and Certifications】 ● Registration for measurement certification related to concentration ● Registration for drinking water quality testing in buildings ● Registered analysis organization for hot spring components ● Designated investigation organization under the Soil Contamination Countermeasures Act ● Registration as a working environment measurement organization Appendix: First/Third/Fourth/Fifth We are also open to consultations regarding emergencies, so please feel free to reach out to us. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAs a result of measuring the combustion conditions at a certain site, the concentration of nitrogen oxides exceeded the standard value. By providing real-time measurement data through continuous monitoring, we assisted the manufacturer in adjusting the burner. This led to a good operating condition without taking much time. We can flexibly respond to such standards, including measurements at intervals of a few minutes and creating reports tailored to the site. 【Overview】 ■ Issues - The measurement of combustion conditions revealed that the concentration of nitrogen oxides exceeded the standard value. ■ Solutions - Provided real-time measurement data through continuous monitoring. - Assisted in achieving good operating conditions quickly through burner adjustments by the manufacturer. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA complaint was received from an office clerk that the office was cold. In response, an air quality measurement was conducted immediately within the office. The results showed that there were no issues within the standard range, but the airflow measurements revealed that the air from the air conditioner was stronger in certain areas, which was contributing to the cold sensation. The perceived temperature can vary slightly depending on the installation location of the air conditioning unit and the angle at which the air hits. 【Summary】 ■Issue - A complaint was received that the office was cold. ■Solution - Conducted air quality measurements. - It was found that the air from the air conditioner was stronger in certain areas, leading to the cold sensation. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is an introduction to a case where volatile substances exceeding 10 times the standard value were detected in a newly constructed office. The measurement results showed that formaldehyde was not detected, but toluene significantly exceeded the standard value. In response, the general contractor implemented a method called "bake-out," which involves forcibly heating the indoor space to drive out volatile substances and ventilate the area. They were able to bring the levels within the standard value in a short period of three days. 【Overview】 ■Issue - Detection of volatile substances exceeding 10 times the standard value in a newly constructed office ■Solution - Response using a method called "bake-out," which involves forcibly heating the indoor space to drive out volatile substances and ventilate *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSchool environmental hygiene refers to efforts to maintain environmental sanitation by properly managing ventilation, color saturation, lighting, and insulation, and keeping the environment clean, with the aim of creating a healthy and comfortable school environment. It also involves making improvements as necessary. This requires conducting various inspections and measurements as stipulated by the School Health and Safety Act's school environmental hygiene standards. The inspection and measurement items defined by the school environmental hygiene standards cover a wide range, including air quality in classrooms, blackboard illumination, surrounding noise levels, water quality tests for drinking and utility water, and pool inspections. Our company can comprehensively address all of these items. In addition to environmental measurements and water quality tests, we can provide a wide range of support, so please feel free to consult us if you have any concerns. 【Main Measurement Items】 ■ Black board illumination measurement ■ Classroom environmental measurement *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe term "working environment" refers to various workplace settings where people work, such as offices, factories, and laboratories. The Labor Safety and Health Act stipulates that various measurements related to the working environment must be conducted to ensure the safety and health of workers. Based on this, it is necessary to accurately understand the working environment, prevent health hazards for workers in advance, and create a more comfortable workplace environment. This is an example of an inquiry from someone who learned about carbon monoxide accidents in the news and wanted to know if their building was safe. Carbon monoxide is extremely dangerous and can affect human life and death. In this case, the actual measurements showed that carbon monoxide levels were within the standard values and that ventilation was sufficient, which provided reassurance. [Overview] ■ Issue - Inquiry about the possibility of a carbon monoxide accident. ■ Solution - Measurements were conducted, revealing that levels were within the standard values and ventilation was sufficient. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDue to suspicion of sick house syndrome, environmental measurements containing volatile substances were conducted. As a result of the measurements, no volatile substances such as formaldehyde were detected. Instead, it was found that carbon dioxide levels were significantly above the standard value, revealing that insufficient indoor ventilation was the cause of the headaches. 【Overview】 ■Issues - There was suspicion of sick house syndrome. ■Solutions - Conducted environmental measurements containing volatile substances. - It was found that carbon dioxide levels were significantly above the standard value, and insufficient indoor ventilation was determined to be the cause of the headaches. 【Causes of Headaches】 Various factors can contribute to symptoms such as headaches. Changes in atmospheric pressure, odors, sounds, light, flashes, taste, stress, etc. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe needs for environmental measurement are indeed diverse, including clean rooms in factories that require high levels of cleanliness, operating rooms in hospitals, food storage warehouses that must maintain certain humidity and temperature levels, as well as surveys of noise and vibration conditions. Our company flexibly responds to such specialized environmental measurements. We received an urgent request from a certain manufacturer for cleanliness measurement in a clean room. Due to renovations in part of the clean room, they requested confirmation on whether the cleanliness was maintained according to regulations, and we immediately conducted verification measurements. As a result, we were able to report that all measured items were below the specified standard values, confirming that a certain level of cleanliness was maintained. Very high precision is required for measurements in clean rooms. 【Overview】 ■Issue - Request for cleanliness measurement in a clean room ■Solution - Reported measurement results confirming that a certain level of cleanliness is maintained *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTo measure the effectiveness of the de-salting filter, we conducted a salinity concentration measurement. The de-salting filter plays an important role in protecting equipment from salt damage. To measure its actual effectiveness, we measured the sodium concentration before and after the removal device in this case. The results showed that it is demonstrating sufficient effectiveness. 【Overview】 ■Issue - Conducted salinity concentration measurement to assess the effectiveness of the de-salting filter. ■Solution - Measured sodium concentration before and after the removal device. - It was found to be demonstrating sufficient effectiveness. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is an introduction to a case where production was halted due to failing to meet the hygiene standards for water used to wash food. Cleaning was performed by another company, but the rust was so severe that it could not be removed. Therefore, we selected cleaning chemicals and carried out cleaning until the hygiene standards were met. Our company is also a registered water quality testing organization, and since we can quickly obtain water quality test results, we were able to minimize the downtime of the production line. 【Overview】 ■Issue - Production was halted due to failing to meet the hygiene standards for water used to wash food. ■Solution - Selected cleaning chemicals and carried out cleaning until the hygiene standards were met. - Achieved the shortest possible downtime for the production line. 【Implementation Steps】 ■Removed rust from the water storage tank using a special cleaning agent. ■Cleaned the water storage tank. ■Conducted water quality testing after cleaning. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt a hospital, water leakage occurred from the panel joints of a tank due to aging deterioration. Repair work was carried out without shutting off the water supply for the hospital. First, a temporary tank was installed, followed by lining work on the internal joints of the tank, and finally, a water quality inspection was conducted to ensure safety. The work was completed with deodorization and without water interruption, tailored to the site conditions. We respond quickly to tank repair work according to the situation on-site. 【Overview】 ■Issue - Water leakage occurred from the panel joints of a tank due to aging deterioration at the hospital. ■Solution - Repair work was carried out without shutting off the water supply for the hospital. - A temporary tank was installed, and lining work on the internal joints of the tank was performed. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe amendment of the Asbestos Hazard Prevention Regulations (effective June 1, 2014) has expanded the scope of asbestos-containing building materials listed in Article 10 (Buildings where workers are regularly employed) from only Level 1 materials to include Level 1 and Level 2 materials. Commonly recognized Level 2 materials include insulation materials, but one that is often overlooked is "Calcium Silicate Board Type 2." Our company proposes a maintenance management method that includes regular environmental measurements. Furthermore, in the final assessment, we can prove that there is "no dispersion" using a more accurate scanning electron microscope (SEM-EDX). Additionally, Article 10 of the Asbestos Regulations holds not only regular workers but also temporary workers accountable from the perspective of occupational safety and health and exposure prevention, with penalties and fines established for businesses. 【Case Study】 ■Challenges - Measures to prevent exposure to asbestos-containing building materials ■Solutions - Proposing a maintenance management method that includes regular environmental measurements - Proving "no dispersion" using a scanning electron microscope (SEM-EDX) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case where we completed the disassembly and cleaning of 150 ceiling cassette air conditioners in one day. This request came from a printing factory, which could only stop the production line on December 30, just before the year-end, and asked us to "clean everything in one day." We were able to respond to the demand for a large number of units and a short turnaround time with the agility of our dedicated team of 50 service engineers. To ensure that we deliver a large number of units without any issues, we create a record for each unit that visualizes the progress of the work. We document any defects or special notes, and the technicians clearly define their responsibilities at each stage of disassembly, cleaning, reassembly, and final inspection to prevent problems before they occur. Additionally, even during winter cleaning, we do not neglect measures against the common issue of "water leakage" that frequently occurs during cooling operations. By filling the drain pan with water during the trial run, we replicate the condensation state of cooling operation and confirm the normal operation of the drainage function, ensuring "peace of mind for six months ahead." 【Case Study】 ■Challenge - Need to clean everything in one day ■Solution - Responded with the agility of 50 dedicated service engineers *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt the ice-making factory, a situation arose where the freezer was unable to cool the brine (antifreeze) to the specified temperature, causing production to stop. We received a request from the company stating, "We had it cleaned by another company, but it was ineffective." Before cleaning, the copper tubes were completely obscured by crystallized calcium chloride, but after cleaning, we were able to remove the crystallized calcium chloride. The brine temperature was also able to drop below -13°C, and the current value of the brine pump improved to the same level as at the time of completion. The customer was very pleased. 【Case Study】 ■ Issues - The freezer could not cool the brine to the specified temperature, causing production to stop. - Cleaning by another company was ineffective. ■ Solution - Planned the work process aiming for the quickest possible recovery. - Removed crystallized calcium chloride. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIf there is no damage to the existing refrigerant piping during air conditioner replacement, it can be reused through cleaning. However, when replacing an air conditioner that involves changing the type of refrigerant, it is necessary to remove the refrigerant oil from the piping. If old refrigerant oil remains in the piping, it can cause issues such as compressor damage. Our company actively promotes the reuse and effective utilization of existing piping by using a specially developed cleaning agent for refrigerant piping, tailored cleaning methods, and measuring the residual oil amount in the piping after cleaning. [Case Study] ■ Issue - Removal of refrigerant oil from the piping is necessary during air conditioner replacement. ■ Solution - Use of a specially developed cleaning agent for refrigerant piping and tailored cleaning methods, along with measuring the residual oil amount in the piping after cleaning. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe received a request for cleaning the drainage pipes of the production system in the clean room from the pharmaceutical factory. Since it is impossible to open the doors to the outside area within the clean room, we laid high-pressure hoses in the ceiling machine room. After removing and bringing in the lighting fixtures, we enclosed the drainage outlet area with a vinyl sheet and performed the cleaning without affecting the cleanliness level. At the end, we restored it with a coupling joint and improved maintainability by processing it so that it can be used as a cleaning access point in the future. 【Case Study】 ■ Issue - It is impossible to open the doors to the outside area within the clean room. ■ Solution - We laid high-pressure hoses in the ceiling machine room, brought them into the room, enclosed the drainage outlet area with a vinyl sheet, and performed the cleaning without affecting the cleanliness level. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA water leak occurred from the air conditioning unit at an automobile parts factory, and we received a consultation from the client stating that cleaning the drain pan did not improve the situation. Generally, drain pipe cleaning is mainly done using high-pressure washing or chemical cleaning. However, with conventional methods, due to the blockage conditions and slope of the drain pipe, cleaning water can overflow from other air conditioning units, causing leaks. Our company eliminates the risk of leaks by creating a negative pressure inside the pipes using "vacuum suction," while also using "chemicals" and "high-pressure water" to more effectively remove dirt from inside the pipes, which has made our clients happy to entrust us with the work. Additionally, to confirm the internal conditions of the piping that are usually not visible, we make it a point to conduct inspections before and after cleaning using an endoscope. [Case Study] ■ Issue - Water leak from the air conditioning unit, and cleaning the drain pan did not improve the situation. ■ Solution - Eliminated the risk of leaks by creating a negative pressure inside the pipes using "vacuum suction." - Effectively removed dirt from inside the pipes by using "chemicals" and "high-pressure water." *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDue to a malfunction where the liquid lithium used in the liquid metal circulation testing device within the factory reacted chemically with air and formed lithium compounds that adhered to the equipment and piping, we received a request for cleaning. We visited the site, conducted dissolution tests on the adhered substances, and considered factors such as the temperature of the cleaning water and the type of cleaning agent. We selected a method that was both safe and efficient, ensuring that safety aspects such as ventilation equipment and recovery containers were thoroughly considered during the operation. As a result, we confirmed through an endoscopic investigation that the adhered substances were completely removed, and we were able to safely hand over the equipment to the customer. [Case Study] ■ Issue - Liquid lithium reacted chemically with air, forming lithium compounds that adhered to the equipment and piping. ■ Solution - Conducted dissolution tests on the adhered substances and considered the temperature of the cleaning water and the type of cleaning agent. - Selected a method that was both safe and efficient. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe received a request to investigate the "black foreign substances" being dispersed from the unit cooler in the factory. 【Case】 ■Issue - We would like you to investigate the "black foreign substances" being dispersed from the unit cooler. ■Solution - Elemental analysis using "Scanning Electron Microscopy - Energy Dispersive X-ray (SEM-EDX)" - Analysis of organic materials using "Fourier Transform Infrared Spectroscopy" and comparison of the surface and cross-section of the foreign substances.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe received a question from a customer asking, "I know that you clean the drinking water tanks, but don't you clean the tanks for the facility water?" Upon further discussion about the type of tank, the customer explained, "We filter well water for industrial use, but the tank that stores the well water is very dirty, and we want to clean it." To confirm the actual situation, we conducted a site visit. After that, we discussed the cleaning method and cleaning agents with the customer, and arranged for a service engineer to perform the cleaning inside the tank. After the cleaning, the customer was able to see the tank in a clean state and was satisfied with the results. 【Case Study】 ■ Issue - The tank that stores well water, which is filtered for industrial use, is very dirty, and the customer wants to clean it. ■ Solution - We discussed the cleaning method and cleaning agents with the customer, and later arranged for a service engineer to carry out the cleaning inside the tank. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt the laundry factory, well water is used for washing, and there were requests regarding the filtration system to "improve the treated water volume of the well water" and "prevent discoloration of the laundry." As a result of the preliminary inspection and investigation, it was found that the "filter media" was dirty. We immediately carried out the "replacement of the filter media." This replacement increased the treated water volume, and the customer was pleased that there was no longer any discoloration of the laundry. Additionally, internal painting and repairs were also carried out at the same time. Our company offers the "replacement of the filter media" at a low price with quality equivalent to that of the manufacturer. Furthermore, regular maintenance and preliminary inspections such as "filter media degradation diagnosis" are also possible. [Case Study] ■ Issues - Want to improve the treated water volume of the well water - Want to prevent discoloration of the laundry ■ Solutions - Carried out the "replacement of the filter media" - Also conducted internal painting and repairs *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDo you have concerns such as "I don't have time," "Ordering is a hassle," or "The costs don't add up"? Our company can handle multiple tasks on the same day, reducing the burden on your staff. For example, if you want to avoid stopping the production line for maintenance as much as possible, we can flexibly conduct cleaning of air conditioners on a scale of 150 units during the factory's consecutive holidays. Please feel free to consult with us. 【We solve the following concerns】 ■ It's a hassle to have multiple suppliers ⇒ By consolidating to one company, you can reduce ordering tasks and achieve more reasonable total costs. ■ I leave equipment matters to the factory's construction staff, but is there a better way? ⇒ It's more efficient to leave it to professionals, as they can achieve better cleaning results in a shorter time. ■ There are various laws and regulations, and it's difficult to keep track of everything. ⇒ Our specialized staff, well-versed in various laws related to water and air, will handle it. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe received a consultation from a factory regarding "high iron concentration in the cold water circulation piping of the production equipment," and we adopted a cleaning method (eco-flushing) to remove iron by installing a "dedicated filter unit" between the headers in the circuit. The filters, which had iron deposits, were regularly removed and cleaned, and cold water was sampled every few hours to check the water quality, with the work carried out for about eight days during the daytime. Additionally, after improving the water quality, we also made maintenance suggestions, such as adding rust inhibitors to prevent the iron concentration from rising again. 【Points】 ■ Significantly reduced cleaning water volume, cutting by 70% ■ Suppressed rusting action, with continued effectiveness through the addition of rust inhibitors ■ Short construction period and cost reduction *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a scientific approach to investigating the causes of refrigerant leaks in welded plate heat exchangers. In the visual inspection, no foreign objects or blockages were found at the cold water inlet and outlet sides, and no external deformations were observed. 【Investigation Overview】 ■ Visual Inspection ■ Air Tightness Test ■ Dissection Investigation ■ Water Quality Test 【Verification Results】 Based on the deformation characteristics of the plates, it is determined that the cause was the expansion of cold water inside the plates due to freezing. Once freezing occurs inside the plates, the circulation flow rate in that area decreases, leading to repeated freezing and increased deformation. In areas other than the deformed sections, no impact was observed on the plate materials, which are stainless steel and copper solder. Therefore, it is concluded that the cause of the gas leak was an incidental issue due to the removal of deposits from previously frozen areas. As a countermeasure, regular water quality management and maintenance are being implemented for improvement. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur company conducts the removal of scale from the condenser of refrigeration units, which causes an increase in power consumption (using chemical cleaning and brush cleaning), to reduce the power consumption of refrigeration equipment and implement peak cutting (demand over suppression). By performing these tasks before the summer season when refrigeration equipment operates the most, we can prevent demand over during peak times at a lower cost than usual, thereby ensuring more reliable energy-saving effects. 【Solution Details】 ■ The cumulative power consumption per day after cleaning is reduced by approximately 25% compared to before cleaning. ■ A reduction of about 20% is expected even during the peak power consumption hours from 1 PM to 5 PM. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt a mechanical manufacturing plant, an outdoor unit equipped with a cooling spray system experienced an abnormal shutdown due to a rise in high pressure during the summer. The outdoor unit had some white substance attached to it, and the company contacted us stating that "it cannot be removed by conventional regular cleaning with high-pressure water." Upon investigation, it was found that hard well water was used in the spray system, causing scale to precipitate and adhere to the fins of the outdoor unit's heat exchanger. Additionally, it was discovered that excessive cleaning with high-pressure water had caused the fins to bend, and the combination of scale and bent fins was blocking the airflow, leading to the high-pressure anomaly. As a solution, we carried out a cleaning process. During this, we used a special cleaning agent to avoid damaging the aluminum fins. The bent fins were also returned to their normal state, resolving the issue. [Case Summary] ■ Issues - The outdoor unit with a cooling spray system experienced an abnormal shutdown due to a rise in high pressure during the summer. - It could not be removed by conventional regular cleaning with high-pressure water. ■ Solutions - Cleaned with a special cleaning agent to avoid damaging the aluminum fins. - Restored the bent fins to their normal state. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is an introduction to a case study that improved the combustion efficiency of a kerosene boiler and achieved cost reduction. In a certain factory, a measurement of the exhaust gas from a kerosene boiler that had been used with its initial settings revealed an air ratio of 1.8, which was causing an increase in fuel costs due to decreased combustion efficiency from excess air. We reported the current situation to the customer and proposed a solution to adjust the air ratio during combustion to 1.3. Our company conducted real-time exhaust gas measurements simultaneously with inspections by the boiler manufacturer. As a result, efficient adjustments became possible, and regular measurements are now conducted to confirm the proper operating conditions of the boiler. [Case Summary] ■ Issues - An air ratio of 1.8 caused increased fuel costs due to decreased combustion efficiency from excess air. ■ Solutions - Proposed a solution to adjust the air ratio during combustion to 1.3. - Enabled efficient adjustments and confirmed the proper operating conditions of the boiler. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn recent years, awareness of environmental issues has increased, and wastewater regulations have become even stricter. However, it is also true that many cleaning companies still discharge wastewater that exceeds regulatory limits. This wastewater issue is considered one of the significant challenges for factories. In response to the request to "collect all wastewater generated during air conditioner cleaning," our company has been working on improving various collection methods. As a result, we have developed dedicated wastewater collection vehicles and wastewater collection kits, establishing a robust system that allows us to collect wastewater from air conditioner parts cleaning as well. Additionally, we have collaborated with manufacturers to develop optimal cleaning agents, implementing measures to minimize the amount of cleaning wastewater generated. Our company aims not only to clean air conditioners but also to pursue environmentally conscious cleaning practices. [Case Overview] ■ Challenge - To collect all wastewater generated during air conditioner cleaning ■ Solution - Developed dedicated wastewater collection vehicles and wastewater collection kits, establishing a robust system to collect wastewater from air conditioner parts cleaning. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Labor Safety and Health Act mandates that workplaces using regulated substances such as organic solvents and specific chemicals in quantities above a certain level, such as factories, must conduct regular work environment measurements. There are penalties for violations. Our company has certified work environment measurement specialists who conduct measurements on-site and evaluate the environmental conditions of the workplace. For example, a hospital requested measurements due to concerns that the indoor formaldehyde concentration might be high. The measurements revealed that the formaldehyde levels indeed exceeded the standard values. As a result, we proposed the installation of local exhaust ventilation systems in areas with high concentrations. Additionally, we recommended and implemented proper storage methods for chemicals in storage areas, which led to a reduction in formaldehyde levels and overall improvement of the indoor environment. 【Case Summary】 ■Issue - There are concerns that the indoor formaldehyde concentration may be high, and measurements are requested. ■Solution - Proposed the installation of local exhaust ventilation systems in areas with high concentrations. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn a factory where drainage inspection and maintenance of the wastewater treatment facility are separately contracted, our company is responsible for the drainage inspection. In one factory, there was a tendency for the wastewater quality to exceed the standards. As a result, under the administrative penalty system, there was an obligation to pay a specified fee depending on the degree of exceeding the standard values. Therefore, the managing company requested the maintenance company for improvements. The maintenance company then implemented improvement measures and conducted a drainage inspection (separately from our company) to prove the effectiveness of these measures, submitting the inspection results to the managing company. However, the results did not reflect the actual situation (with suspended solids SS at 0 mg/L, indicating no suspended matter at all), and the data was unreliable. By the way, the data from the drainage inspection conducted by our company around the same time was near the standard value (200 mg/L) and yielded different results. Considering such cases, it is deemed effective to conduct cross-checks by a third-party organization like ours when drainage inspections are not separately contracted.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce examples of refrigerant ammonia recovery and decontamination work associated with the repair and removal of ammonia refrigeration systems. The number of refrigeration systems using ammonia as a refrigerant, which existed in large numbers 30 to 40 years ago, has decreased due to aging and removal, leading to a reduction in engineers capable of maintenance. Our company has a proven track record in recovery and decontamination associated with the removal of various facilities such as large cold storage warehouses and ice factories, and we have engineers capable of handling complex systems. Using our unique decontamination equipment, we can carry out decontamination work safely, quickly, and with consideration for the environment. 【Features】 ■ Engineers capable of handling complex systems ■ Not subject to the Manufacturing Act of the High-Pressure Gas Safety Act, no prior notification to authorities required ■ Quick response possible even in cases requiring urgent repairs ■ Implementation of safety measures within the system to ensure that repairs, removals, and demolition work can be carried out safely *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration