The Eaton Curve Select is software designed to analyze and adjust the characteristic curves of various protective devices. It allows you to display the characteristics of different devices on the same graph while changing the settings, making it a very convenient tool when considering selectivity. It clearly displays the characteristics from large circuit breakers to motor breakers and fuses, and allows for the adjustment of trip characteristics. It also includes support functions to match motor starting characteristics. Since it is in Excel format, operations such as input and display are easy. Additionally, it has a robust printout function for official documents. Please download the catalog (manual) and take a look.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- This is an accessory that can be mounted on the side or door of the control panel, allowing operation from the back of the circuit breaker. - It currently complies with IEC standards and is expected to obtain UL certification. - It is designed to be installed on our 3-pole circuit breakers NZM1 or NZM2 (rated current 16-250A). - It has been achieved by using invisible screws in four directions. - It is a lifesaver when there are space limitations inside the control panel.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe provide a technical book and service that thoroughly explains the recent hot topic of SCCR (Short-Circuit Current Rating) labeling requirements for machinery exports to North America. Please feel free to consult with us. Introduction to the materials: 1. Overview - Summary of the 2005 NEC revision - Mandatory SCCR labeling - Purpose of the revision - SCCR is not the short-circuit interrupting capacity - Using current-limiting circuit breakers can increase SCCR - Assemblies are certified as a whole 2. Method for determining the SCCR of control panels - Timing for implementing SCCR - Introduction of SCCR implementation examples - Kind support from Eaton
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn North America, there are two standards for circuit overcurrent protection devices: UL489 and UL1077, which have different requirements. It is important to note that the permitted usage methods differ between UL489 compliant products and UL1077 compliant products. Additionally, we will provide a free explanatory document that clearly outlines the differences from the international standard IEC. This is a must-read for customers exporting machinery to North America.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationEaton's high-performance, robust, and compact T cam switch & P load disconnector is used in industrial, commercial, and construction engineering applications. There are 10 types of basic switches (TM, T0, T3, T5, T5B, T6, T8, P1, P3, P5) with 4 mounting options (surface mount, flat mount, rear mount, and service distribution board mount). These can be selected and set with a variety of contact sequences. 【Features】 ■ Compliant with IEC60947, 60204 ■ UL, CSA, CCC, EAC, Lloyd’s Register ■ Compliant with IEC60947-3 as a load disconnector. Can be used as an emergency stop switch since it can interrupt the operating current. ■ Can be locked with up to 3 padlocks on the handle ■ Insulated case with double insulation structure ■ IP65 dustproof and waterproof structure ■ Best-in-class AC-23A rating for switching inductive currents
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration◆Compact Control Panel + Easy Labor Savings Realized◆ The MSC Motor Starter integrates a manual motor starter and a contactor with a dedicated plug, achieving a reduction in control panel size and wiring labor. 【Features】 ■ The manual motor starter has an adjustable thermal protection built into the main unit. It is a compact and multifunctional breaker with built-in short circuit protection, overload protection, and phase loss protection. ■ The wiring between the manual motor starter and the contactor is done with a dedicated plug, requiring no tools. Additionally, they are mechanically linked, eliminating the need for a base plate (max. 15A). ■ Flexible combinations are available, standardizing a wide range of DOL and reversible units from 0.16A to 15A (tool-free) and from 15A to 40A. There are also plenty of options available, including alarm contacts. ■ By simply adding a dedicated connection terminal on the primary side, it complies with UL508 Type F. There are no additional conditions for using other accessories. It also complies with CE/CCC standards. *For more details, please inquire via 'Request for Information' or 'Catalog Download'.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTerminal block ideal for wiring branch circuits How do you wire from the secondary of the main switch to individual branch circuits? Generally, it is done by: - Performing jumper wiring - Providing a perforated bar - Using a branch bar However, when considering the wiring in this area from the perspective of standards, particularly compliance with North American standards, it is necessary to take various requirements into account. North American standards - NEC, NFPA79, UL508A - apply what is known as the "tap rule" to this area, and unless these wiring regulations are followed along with proper equipment selection, it cannot be said to comply with North American standards. By using the power distribution block (PDB) from Moeller, wiring in this area can be done easily and in compliance with the aforementioned North American standards. Additionally, by using this PDB in combination with specified fuses, the SCCR value can be set to 100kA. ● Compliant standards: UL, CE, IEC ● Rated current: 115-310A/UL, 125-400A/CE ● Number of poles: 1P/3P
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a breaker/load switch compatible with system voltages of DC900V/DC1000V. It is ideal for medium-sized to mega-solar class photovoltaic power generation systems, making it easier to group PV panels and allowing for the miniaturization of connection boxes.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe FAZ-DC miniature circuit breaker is a protective device equipped with both thermal and electromagnetic release, available in single-pole and double-pole versions. FAZ can be used with rated currents from 2A to 50A. The switching capacity is 10 kA in accordance with IEC/EN 60947-2. The DC rated voltage is 220V per pole for the 2A version and 250V per pole for the 3A to 50A versions. It features a guide for safe terminal connections and a 3-position DIN rail, making the installation of the circuit breaker easy.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- GFCI (Ground Fault Circuit Interrupter) complies with the GFCI (UL943 standard: Ground Fault Circuit Interrupter for personal protection) required for service outlet circuits in control panels as specified by NFPA79. UL489 certification is also obtained. - NFPA79:2007 15.1.1.1(1) stipulates that receptacle (outlet) circuits installed outside the control panel for electric tools, testing equipment, etc., must be protected by GFCI. - NFPA79:2007 15.1.2 stipulates that receptacle (outlet) circuits installed inside and outside the control panel for maintenance purposes must be protected by GFCI. - UL508A requires that receptacle (outlet) circuits be protected by breakers that comply with UL489 standards.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Current Monitoring Relay ES/EC Series - Monitors overcurrent/undercurrent against the set current value of AC/DC circuits and outputs contact signals. - Measurement current is available in a series from 1 to 200A. - Integrated CT for space-saving. - Power supply options include self-powered, loop-powered, and separate power supply types. - CE/UL certified products. ● Current Conversion Sensor EA/ED Series - Converts AC load current into an analog signal. - Available in a series from 0-20/200/300/400A. - Output signals are available in three types: 0-5V, 0-10V, and 4-20mA. - Power supply options include self-powered, loop-powered, and separate power supply types. - CE/UL certified products. ● Leakage Monitoring Sensor EGF Series - Space-saving design with integrated leakage detection sensor (ZCT). - Sensitivity current options are 5/10/30/50/100mA. - CE/UL certified products.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Global compatibility Products compliant with UL/CSA/CE standards UL compliant with UL508 standard, usable up to 100% RoHS directive compliant products NEC Class II compliant products - Wide input voltage range Single-phase AC 100-240V (85-264V) Three-phase AC 400-500V (320-575V) Can be directly connected to three-phase AC power, eliminating the need for a control transformer Therefore, it simplifies panel miniaturization and temperature management within the panel - Output voltages are DC12V and DC24V - 150% overload capability
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Energy Efficiency In the United States, the Energy Policy Act of 2005 (EPAct 2005) and the federal law specified in 10 CFR Part 431 require that low-voltage dry-type distribution transformers (15 kVA and above) sold and used in the U.S. and its territories after January 1, 2007, must meet the energy efficiency requirements set forth in the NEMA standard TP1-2002. - UL Standards Naturally, it complies with UL standards. Additionally, we can supply three-phase distribution and power transformers that meet this NEMA standard TP1-2002. - Specifications Please specify the primary voltage/secondary voltage. Please specify the capacity and connection method (e.g., Δ/Y). Please specify whether it is a standalone transformer or packaged.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Can also be used as a power collection breaker in the junction box ● Has switching capability at a rated voltage of DC750V, allowing ON/OFF during power supply ● Complies with IEC/EN60947 standards
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWould you like to save time and costs? ● Maintenance-free Lineup of 300A/600A at DC1000V Maximum switching life of 150,000 cycles Significantly reduces maintenance costs ● Abundant coil drive options Achieves optimal ON/OFF with three types of coil drives Wide input coil voltage range of 110-250VAC/110-350VDC Direct drive from DC output of PLC is also possible ● Flexibility Non-polarity allows for no specification of connection direction (positive/negative) Also supports operating ambient temperatures from -40 to +70°C, making installation location flexible ● Compliance with global standards Complies with IEC/EN standards, and plans to obtain UL/CSA/CCC/GL/DNV certifications ● Hybrid contacts Hybrid contacts for arc extinguishing and insulation release IGBT elements are also arranged in parallel for arc extinguishing contacts These combinations and controls achieve long life.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationEssential for electrical system wiring, these are the earth seals and lightning marks. - Earth mark seal: Diameter 9mm, 100 pieces per bag - Lightning mark (small): 22mm tall x 25mm wide, 50 pieces per bag - Lightning mark (medium): 48mm tall x 43mm wide, 20 pieces per bag - Lightning mark (large): 140mm tall x 122mm wide, 10 pieces per bag
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe CI case is the most reliable control panel case with a 'double insulation' structure that our company has adopted for the first time. - With a protection structure of IP65, it can be used in any environment. - It demonstrates high reliability and safety for human protection and equipment protection. - Being a box type, it allows for various combinations and is easy to expand. - It features a 'total insulation = double insulation' structure, which does not age. The term 'total insulation = double insulation' was first used by our company and was later adopted by IEC standards. - There are also our products housed in CI cases. This not only saves assembly time but also enables the use of products in harsh environments on their own. - It is made of fiberglass-reinforced polycarbonate.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Eaton Moeller series MCS pressure switch is a control device that measures the pressure of a medium and converts that information into an electrical signal. It is used for monitoring the pressure of liquids and gases. The MCS pressure switch has two adjustable operating points (on and off operating points).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Up to 5 levels can be operated individually. - Any combination of continuous lighting, flashing, strobe light, and buzzer is possible. - Easy installation. - Various installation methods: direct on the base module, remote installation on a stand or spacer, and wall mounting using installation brackets.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationMain Features: Flexible copper bar (electrified wire) CU-BAND that sets a new standard 【Conductor Material】 - High conductivity Cu-ETP 99.9 - Tin-plated thin copper sheet - Suitable for drilling and punching 【Insulation】 - Reinforced edges to improve resistance - High operating voltage - Homogeneous and stress-free insulation (no edge bursting) - Higher thermal short-circuit resistance compared to bars and cables of the same class - Abundant color variations - Self-extinguishing in accordance with UL94 V0 【General Specifications】 - Rated operating voltage: 1000 VAC / 1500 VDC (UL standard below 600 VAC) - Insulation resistance: 20 kV/mm - Insulator heat resistance temperature: up to +105 °C - Length: 2000mm - UL certified
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- This is a relay that monitors the phase sequence, overvoltage, undervoltage, and phase loss (below 60% of the rated operating voltage) of a three-phase power supply. - The monitoring voltage range is adjustable. - It monitors the three-phase voltage within the range. - It is possible to select either on-delay or off-delay (0.1-10 seconds).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a versatile, rail-mounted type of panel-mounted outlet. - Complies with VDE and ÖVE - Easy to install in the panel due to rail mounting. - Number of poles: 2 poles + PE - Rated current: 16A, rated voltage: 250VAC - Connection wire size: 1-25mm², 2×1-25mm² - Front dimensions: 75mm (height) × 44mm (width)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- This is for the control of conveyor systems that use a relatively large number of small motors (from 0.09 to 2-3 kW). - The unit contains electronic circuits and contactors or inverters, controlling one motor per unit. - It is compatible with AS-i bus and can process sensor signals locally. - Power cables are consolidated into a single flat cable, allowing for tap-off connections without the need to strip the cable insulation. - By using commercially available gateways, it can connect to any fieldbus at a higher level without any need for program changes. - Each unit has a manual mode function, allowing for quick resolution at that location without stopping the entire system. - Each unit has a protection structure of IP65. - Overall installation labor for the project can be reduced by approximately 30-50%. - There are numerous achievements in European airport baggage conveyors.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSpecial contactor for three-phase capacitors - It is a special specification that can be used in power factor correction circuits without a choke. - In group power factor correction circuits, especially those primarily connecting multilayer capacitors, inrush currents can reach up to 180 times the motor rating, but this circuit is also suitable for such applications. - It comes with a series resistor. - The special pre-charging auxiliary contacts and resistor charge the capacitors before the main connection, reducing inrush current. - Some models come with discharge resistors for capacitors. This can prevent polarity reversal that occurs during repeated high-speed connections. Composite discharge time is 0.2 seconds.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationZEV Electronic Thermal Relay - Revolutionary Motor Protection Adaptable to Motor Currents from 1 to 820A - The ZEV electronic thermal relay from Moeller has seen technological improvements and reduced costs. - It utilizes a super compact current transformer that is 1/58th the size of conventional transformers, significantly saving space in control panels. - The sensor is small, lightweight, and has a very wide range of current compatibility, making selection easy. It has fewer components, simplifying inventory management. - Installation is easy, requiring only Velcro to secure the sensor, with no complicated wiring or drilling needed. - Settings are simple with button operation and LED display. - It can handle the most severe starting conditions, with the trip class strengthened up to Class 40, ensuring reliability even during long starting times. - Ground fault currents are immediately detected by an external SSW zero-sequence current transformer. It also has a built-in connection for thermistors, allowing for expansion into a complete motor protection system.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationMüller's Z series thermal relays protect motors from phase loss and overload. The auxiliary contacts disconnect the motor circuit and also provide a fault signal. They are also suitable for protecting EEx-rated motors. We minimize the number of models to reduce inventory management costs. For sizes up to 250A, they can be directly mounted on our DIL series contactors (see photo) or can be installed separately.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a global specification miniature circuit breaker compliant with CE (Europe), UL1077 (North America), and CCC (China). It supports a variety of applications such as semiconductor protection, cable protection, and control transformer protection with six types of trip characteristics (B, C, D, Z, K, S). As a compact circuit breaker, it has a short-circuit breaking capacity of 15kA. The rated current ranges from 0.5 to 63A. When using a remote operation unit, automatic restart is possible in the event of an unnecessary trip. There are also bridging bars available for neat installation of equipment of different sizes. It can be used not only in factories but also for the protection of building systems.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- The selector switch comes in beak shape and knob shape. - The beak-shaped selector switch has a lighted type, which has received praise for its aesthetic design. - The knob type can also have customer-specified characters printed on it. - The colors available for the lighted selector switch are white, red, green, and blue. - The key switch can be set to either momentary or alternate. There are models that allow for the selection of the key insertion position. - All products have front ring colors available in titanium, black, and gold. - All products have a protection structure of IP66.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- You can select and set either momentary or alternate. - The push button is also available in a lighted type, enhancing visibility in dark environments. - The central part of the two-point push button serves as an indicator light. - Protection structure: The push button is IP67 or 69K, and the two-point push button is IP66. - The front ring is available in titanium color, black, and gold. - The operation part comes in flat, protruding, and mushroom shapes. - Custom special characters or shapes specified by the customer can also be laser printed.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationPrevents unauthorized operation and ensures exceptional reliability. The Müller safety door limit switch features a double break contact system, making it suitable for constructing multiple safety circuits. It has interlocked opposing contacts and a forced disconnection mechanism based on IEC/EN60947-5-1. Therefore, it is compatible with electronic devices according to IEC/EN61131-2. The AT0-ZBZ has two types of operating principles: electromagnetic locking and spring locking. In the electromagnetic locking type, the lock engages when voltage is applied to the machine, allowing it to be opened directly during a power outage. In the spring locking type, the door remains locked even during a power outage. The lock is released when voltage is applied to the AT0-ZBZ. This mechanism protects the human body from machines that are overrunning. The lock is only released when dangerous operations have stopped. - Can be installed in any location. - Actuator head rotates 4×90 degrees. - Six types of actuator heads cover the range.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationLarge contactors for reliable opening and closing up to 2000A: DILM185A to 1000A, DILH1400A to 2000A. These are electronic contactors. **Advantages of being a vacuum contactor:** - Compact size - Since opening and closing occurs within a vacuum-sealed tube, it is unaffected by external influences, resulting in a long lifespan even when switching high currents. - No gas can enter from the outside during opening and closing. - No arcing occurs, leading to less wear on contacts and allowing for high-density installation configurations. **Advantages of being electronic:** - Flexible operation. - Holding power has been reduced to just 4% of the conventional level, significantly lowering the temperature inside the control panel. - Power consumption during operation is also only 21% of the conventional level, allowing for smaller transformer sizes. - It can accommodate a wider voltage fluctuation range than specified by standards. - Optimizing connection strength has extended the lifespan. - Surge absorption coil is built-in. - Comes with two a contacts and two b contacts as auxiliary contacts.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSEMI F47 fully compliant electronic drive contactor DILMF (up to 150A) - It meets all the requirements of SEMI F47, making it ideal for use in the semiconductor industry. - It has a built-in rectifier in the coil terminal input section, allowing it to operate in direct current internally. Therefore, there is no 'hum' generated, making it suitable for building applications. - Since it has a built-in rectifier, it can be used at frequencies of 50 to 400Hz. - It covers control voltages of 24VAC, 42-48VAC, 100-120VAC, and 190-240VAC with four types of coils. - It can also be used in combination with inexpensive non-smoothing bridge rectifiers.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFor machines that pose a significant danger to the human body, dual-hand operation is mandatory, and the time interval for dual-hand operation must be within 500ms. By using our ESR4-NZ-21 for this time-series monitoring, it complies with safety category 3C of EN574.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFor monitoring safety circuits, the Müller safety relay ESR series instantly or with a delay interrupts multiple current circuits when the emergency stop mechanism is activated. Depending on the circuit configuration, it can detect short circuits, ground faults, and short circuits in emergency stop circuits. It immediately interrupts after detection or prevents restart until the cause of the fault is removed. Safety relays that comply with Category 4 require an additional restart monitoring function, and our products meet this requirement. This also serves as a mechanism to prevent unauthorized operation. The ESR series complies with either EN954-1 categories 2 to 4, depending on the model. If more contacts are needed, the expansion unit ESR4-NE can increase the number of circuits up to four. For less stringent applications (such as stop category 1 in EN60204-1), the ESR4-NV delayed action safety relay is suitable, allowing for delays of up to 30 seconds.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationPreventing unauthorized operation and ensuring exceptional reliability, the Müller safety door limit switch features a double break contact system, making it suitable for constructing multiple safety circuits. It includes interlocked opposing contacts and a forced disconnection mechanism based on IEC/EN60947-5-1. Therefore, it is compatible with electronic devices according to IEC/EN61131-2. This hinge/hasp type safety door limit switch is effective in locations where an operating lever cannot be installed. It detects even a mere 5-degree angle of opening and closing, completely preventing unauthorized operation. The installation conditions are flexible, allowing for surface mounting, compact cases based on EN50047, or wide cases. The actuator rotates 4×90°.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationPreventing unauthorized operation and ensuring exceptional reliability, the Müller safety door limit switch features a double break contact system, making it suitable for constructing multiple safety circuits. It includes interlocked opposing contacts and a forced disconnection mechanism based on IEC/EN60947-5-1. Therefore, it is compatible with electronic devices according to IEC/EN61131-2. **Features of AT4-ZB:** - The actuator head can be used from both sides, providing high flexibility. - The switch allows for horizontal and vertical mounting, even with actuators inserted from one or more directions. - The case comes in three sizes. - It complies with EN1088. **Features of AT0-ZB:** - The actuator can be operated in five directions, with insertion possible from four directions and the top. - It complies with EN1088.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Eaton Moeller series robust foot-operated palm switch (FAK) features a large actuator that can be operated quickly and intuitively. Additionally, it is equipped with a design that prevents accidental operation. The FAK switch can be operated with the hand, fist, or foot, allowing the operator to respond quickly and safely in any situation, protecting people, machines, and systems. With high mechanical shock resistance and an extremely high protection rating (IP67, IP69K), the FAK switch is ideal for use in harsh environments.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is the ideal breaker for motor protection. - A multifunctional breaker compatible with various national standards such as CE (Europe), UL (North America), and CCC (China). - The breaker body has an adjustable thermal function built-in, eliminating the need for a separate thermal relay. - In addition to the conventional rotary operation type, a push-button type (PKZM01 type, up to 16A) has also been introduced. - It reliably interrupts short-circuit currents up to 150kA, making it suitable for systems with large short-circuit currents. - The trip block of the PKZ2 type breaker can be easily replaced without tools, allowing for simple capacity changes without replacing the breaker body. Rated current: - PKZM01: 0.1 to 16A - PKZM0: 0.1 to 32A - PKZM4: 10 to 63A - PKZ2: 0.4 to 40A
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a push-button type circuit breaker for small capacity motor protection. - Rated current up to 16A - When combined with an emergency stop push button and placed in a case (photo on the right), it can also be used as an emergency stop switch for relatively simple machinery. - In that case, the protection structure is up to IP65.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will reduce the size of the panel! The busbar adapter is a wiring accessory that covers the copper busbar and allows for the installation of control equipment on the front. - Space-saving for starters inside the control panel - Pre-wired, so no tools are needed, significantly reducing work time - Savings on branch wiring materials - No need to worry about wire sizes for North America (UL compliant) and Europe (CE compliant) - Busbar adapters are available for 125A, 250A, and 630A. We strongly recommend this to customers with the following conditions: - Using a main breaker rated at 125A or higher in the distribution or control panel - Need for compacting the size of the distribution or control panel - Want to reduce the total cost of the distribution or control panel - Have many three-phase motors and load equipment (more than 11 units) installed in the machinery.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationMain switch for emergency stop designed to match the recent trend of unitized machinery. It is a combination of a motor protection breaker (0.1 to 65A, short-circuit interruption capacity of 150kA) and an emergency stop push button. It allows for inexpensive, simple, and safe operation when a relatively small interruption capacity is sufficient. It can be combined with surface-mounted covers for IP40 and IP55, and cases for IP65 (waterproof and dustproof structure) (see photo). The emergency stop push button complies with UL (North America), CE (Europe), and CCC (China) standards, achieving a protective structure of IP66 or higher without the use of covers like rubber caps. Additionally, we offer a variety of resin cases specifically for push buttons.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a breaker specifically for transformer protection. To prevent unnecessary trips caused by the large inrush current of the transformer, the instantaneous disconnection value is set to 18 to 22 times the maximum continuous current. The thermal trip is adjustable, allowing for optimal protection tailored to the primary current of the transformer.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIdeal for a machine that handles a simple motor. - There are various types of cases available (rotary handle, push-button type). - It has a waterproof and dustproof structure with an IP65 rating. - There are also embedded mounting covers with IP40 and IP55 ratings. - The PKZ motor circuit breaker inside the case supports rated currents from 16 to 65A in three sizes. - Additionally, it reliably protects against short-circuit currents up to 150kA. - This single unit protects against overload, phase loss, and short circuits.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOriginal by Müller: The world's first electronic limit switch LSE-Titan. - The operating point can be easily and reliably changed with just one switch, eliminating the need to change the position of the switch once it is installed (the method for changing it is explained in an animation on our website's limit switch page). - The semiconductor PNP output replaces the contacts, providing bounce-free operation, 100% contact reliability, and strong resistance to noise. - Equipped with short-circuit and overload protection features. - Status indication with LED light. - Certified based on safety category 3 in EN945-1 and TUV 'mechanical safety', making it suitable for use in safety circuits. - Protection structure IP65.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a four-directional operation switch that allows for the on/off control of four contact points with a single installation. (1) Four-point push button - The four-point push button is convenient to use as a switch to drive the machine in four directions. - Arbitrary marks or characters can be printed on the four push surfaces using laser printing. (2) Joystick - The joystick also has contacts in four directions, enabling four-directional control. (3) Selector switch - There is also a selector switch for four-directional operation, available in dial and knob types. - Each has four points for on and off, making a total of eight contact elements. - The rotation angle is 360 degrees. * Nameplates Various nameplates are also available, including plain types, direction arrow printed types, and '0-1-0-2-0-3-0-4' printed types. Additionally, special character printing can be done upon order. Customers can also design their own laser printing images using the free label editor software provided.