Full support for time-lapse photography without failure with new features such as easy operation via touch panel! 【Features】 - Accurate temperature control through a database with the included software - Uniform heating regardless of observation container, from dishes to multi-well plates - Automatic image transfer to mobile phones and tablets via the included software, allowing for remote verification at home - Standard temperature programming included in the software, with built-in CO2/O2 programming - One-touch fixation of dishes - Reduced to just four connection cables for quick setup *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "PureBox SHIRAITO" is a clean box for microscopes that can be attached to Olympus IX83 or Nikon Ti2. It allows observation at a cleanliness class of 100 (equivalent to ISO Class 5) and enables operations such as media exchange while maintaining cleanliness. In addition to keeping the internal temperature at 37°C through temperature control, it features a unique structure that minimizes fan vibrations. 【Features】 - Supports sterile operations such as cell culture - Equipped with HEPA filters that capture 99.97% of particles larger than 0.3μm - Provides ample workspace - Equipped with a non-contact LED switch - Includes a cell-friendly red LED light *For more details, please refer to the materials. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt manages the temperature, humidity, and CO2 necessary for cell culture on the microscope stage, enabling long-term culture observation. It is a culture device for upright microscopes that can also perform high-magnification observations such as confocal microscopy.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDue to the adoption of feedback control, precise temperature adjustment near the sample is possible. - Comes with a dedicated chiller - Sample temperature feedback control - Compatible with 35mm dishes, slide glass, chamber slides, and cover glass chambers
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "PMD-D35" is a fluid control system that can automatically perform perfusion, medium exchange, drug administration, and mixing necessary for cell culture through program control. Settings can be easily made via the front touch panel, and it can operate on weekends and at night, reducing the workload for operators. It has a built-in tube heater, allowing for the warming of culture media and reagents with this single unit. It can also be used with existing culture devices, and the created programs can be saved to a USB memory, allowing for individual management of each user's program list. 【Features】 ■ Mixing operations are possible during drug administration ■ Minimal changes in medium volume due to medium exchange ■ Compatible with external devices such as microscope software ■ Standard 35mm dishes can be used *For more details, please refer to the materials. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOn the microscope stage, cell culture equivalent to that of a CO2 incubator can be achieved with the "Microscope Culture System," which now includes additional options for "perfusion" and "media exchange"! Since it can be used with the lid closed, perfusion prevents contamination and enables long-term culture. This option greatly expands the range of experiments for time-lapse imaging. 【Features】 ■ Compatible with commercially available 35mm dishes ■ Height adjustment for perfusion and media exchange pipes is possible *For more details, please refer to the catalog or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOn the microscope stage, cell culture equivalent to that in a CO2 incubator can be performed. An additional option for "drug administration" has been added to the "microscope culture system"! Since it can be used with the lid closed, long-term culture has become possible. This option greatly expands the range of experiments that can be conducted with time-lapse imaging. 【Features】 ■ Quantitative drugs measured with a pipette can be administered. ■ Administration starts automatically with the push of a button. *For more details, please refer to the catalog or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationYou can set up a hypoxia environment with easy settings.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationCO2 concentration: 1.0% to 20.0% CO2 flow rate: 50 to 200 ml/min Gas cylinder used: 100% CO2
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA cartridge-type gas supply system has been introduced for microscope culture systems. This space-saving, quick-start cartridge gas supply system can be used for about three days with one cartridge. No need to operate a gas regulator; it supplies the optimal gas for the culture system with the simple push of a button. We solve your concerns about handling gas. 【Features】 < Cartridge-type Gas Supply System > ■ Space-saving No more worries about securing space for gas cylinder placement! It can be fixed to existing controllers using the rear magnet! ■ Quick start An easy gas supply system that can be used immediately after opening the box! One cartridge lasts for about three days! ■ Easy to use No need to operate a gas regulator! It supplies gas at the optimal flow rate for the culture system with just one button! *For more details, please refer to the catalog or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThermoPlate is a product that allows for more accurate and reliable temperature management during microscopic observation. It meets various temperature management needs across different fields, including biological and industrial applications, and is supported by a rich lineup of products. The temperature control unit adopts PID control as standard, achieving ideal temperature regulation with fast response times and high stability against disturbances. The temperature measurement section is designed with sensors placed at optimal locations on the transparent heating element surface, resulting in excellent thermal responsiveness between the temperature measurement area and the center of the plate, minimizing overshoot when powered on and fluctuations in surface temperature due to disturbances. The heating plate is made of a specially processed transparent heating element with hard glass, suitable for observation using phase contrast, differential interference, and polarized microscopes. For more details, please contact us or refer to the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt can also accommodate observations using phase difference, differential interference, and polarized light microscopy.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt can also accommodate observations using phase difference, differential interference, and polarized light microscopy.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSince the entire heater is heated, temperature management is performed not only for the samples being observed but also for the samples on standby. This is very useful when handling a large number of samples.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt can also accommodate observations using phase difference, differential interference, and polarized light microscopy.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt minimizes the influence of ambient temperature and the focus drift caused by thermal expansion during the heating stage. Standard PID control is employed to achieve ideal temperature control, resulting in fast response times and high stability against disturbances.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt can also accommodate observations using phase difference, differential interference, and polarized light microscopy.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationPlate surface temperature: Adjustable from 4℃ to 60℃. Please choose between the type with a chiller for long-term use and the cooler box type for a few hours.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt can also accommodate observations using phase difference, differential interference, and polarized light microscopy.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationStandard PID control, which achieves ideal temperature control, is adopted, resulting in fast startup and high stability against disturbances. 15mm width type 10mm width type (used when the winding area is limited due to the presence of correction rings, etc.)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt suppresses overshoot and always maintains accurate and stable temperature control. By adopting PID control as standard, which achieves ideal temperature control, it has a fast startup and high stability against disturbances.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt is possible to suppress the temperature decrease of the sample due to heat transfer to the sensor and accurately measure the temperature with minimal influence from the ambient temperature.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a CO2 chamber mounted on a stereo microscope stage that allows for the observation of long-term cultures for more than 7 days and enables high-magnification observations such as confocal microscopy.