[Analysis Case] Ultra-high Sensitivity Measurement of Impurities in Silicon Using SIMS
We will enhance the sensitivity and evaluate the concentration distribution at the ppt level.
The detection sensitivity in SIMS analysis depends on the amount of sputtered sample per unit time. Depending on the element, significantly improved sensitivity can be achieved by limiting the impurities to one element, allowing evaluation down to ppt (parts per trillion) levels of less than 5E13 atoms/cm3, which is effective for assessing low-concentration impurities in IGBT devices and high-purity wafers. This document presents examples of ultra-high sensitivity evaluations of low-concentration impurities in silicon.
Inquire About This Product
basic information
For detailed data, please refer to the catalog.
Price information
-
Delivery Time
Applications/Examples of results
Analysis of solar cells, power devices, LSI, and memory.
catalog(1)
Download All CatalogsCompany information
MST is a foundation that provides contract analysis services. We possess various analytical instruments such as TEM, SIMS, and XRD to meet your analysis needs. Our knowledgeable sales representatives will propose appropriate analysis plans. We are also available for consultations at your company, of course. We have obtained ISO 9001 and ISO 27001 certifications. Please feel free to consult us for product development, identifying causes of defects, and patent investigations! MST will guide you to solutions for your "troubles"!