Scribner expands the possibilities of battery evaluation from fuel cells to secondary batteries.
Scribner Product Introduction High-precision measurement and evaluation solutions supporting research and development of fuel cells and secondary batteries Scribner provides various measurement and evaluation systems tailored for the research, development, and performance evaluation of fuel cells and secondary batteries. For fuel cell evaluation, we offer systems that combine electronic load devices with control software, allowing for automatic evaluation tests while controlling power generation conditions such as fuel flow and cell temperature. This supports efficient automatic evaluation for long-duration tests involving changes in power generation conditions and repeated measurements. For secondary batteries, we provide high-precision charge and discharge systems, impedance measurement capabilities, and evaluation systems compatible with five-terminal measurements. Additionally, we offer specialized measurement solutions tailored to specific applications and research content, such as performance evaluation of redox flow batteries. From fuel cells to secondary batteries and redox flow batteries, we comprehensively support the measurement and evaluation environment necessary for battery research. For product specifications, measurement methods, system configurations, and more, please feel free to contact InterChem Co., Ltd.
Inquire About This Product
basic information
Scribner Battery Evaluation and Fuel Cell Evaluation System We provide high-precision battery evaluation and measurement systems that support research and development of fuel cells, secondary batteries, redox flow batteries, and water electrolysis. ■ Fuel Cell Evaluation 850 and 840 series fuel cell testing systems, 855 series SOFC/SOEC testing systems, and 890 series electronic loads. Supports I-V characteristics, CC/CV/CP control, membrane resistance and impedance measurement, and fuel flow and temperature control. ■ Secondary Battery Evaluation 580 and 585 series charge/discharge measurement systems are available. Supports up to 24 channels, 5-terminal and 6-terminal measurements, CC/CV/CP control, impedance measurement, and temperature-controlled chamber integration. ■ Redox Flow Battery Evaluation With the 857 Electrochemical Flowbench, charge/discharge, EIS/HFR, SOC, and electrolyte flow and temperature can be controlled from a PC. ■ Water Electrolysis Evaluation Evaluation of electrolysis cells such as PEM/AEM/SOEC, control of current, voltage, gas flow, and temperature, as well as long-duration endurance tests and automatic measurements.
Price range
Delivery Time
Applications/Examples of results
Applications and Examples of Achievements ■ Fuel Cells and Water Electrolysis Performance evaluation of PEMFC, AEMFC, SOFC, SOEC, I-V characteristic measurement, durability testing, automatic evaluation of power generation and electrolysis conditions. ■ Secondary Batteries Charge and discharge testing of lithium-ion batteries and all-solid-state batteries, performance evaluation of battery materials and cells, degradation analysis, impedance measurement. ■ Redox Flow Batteries Evaluation of charge and discharge performance, state of charge (SOC), electrochemical impedance spectroscopy (EIS) and high-frequency resistance (HFR), control of electrolyte flow rate and temperature. ■ Main Applications Research and development in universities and research institutions, material evaluation for companies, performance evaluation of cells and stacks, long-duration durability testing, construction of automatic measurement systems.
Detailed information
-

Multi-Range Electronic Load 890 Series for Fuel Cells
-

Electronic load 890ZV for fuel cells with 0V support
-

Membrane Resistance Measurement System MTS740
-

Fixture for fuel cell cells
-

857 Type Redox Flow Battery Evaluation System
-

580 and 585 series charge and discharge measurement systems
Line up(6)
| Model number | overview |
|---|---|
| Fuel Cell Evaluation System (FUEL CELL TEST SYSTEMS) | Scribner's fuel cell evaluation system supports research and development and performance evaluation for PEMFC, AEMFC, DMFC, SOFC, and SOEC. It integrates electronic load, gas flow, humidification, and temperature control, enabling I-V characteristics, membrane resistance, impedance measurement, long-term durability testing, and automated evaluation. The lineup includes models such as the 850, 840, 855, and 890 series. |
| Scribner 890ZV Advanced SOFC Fuel Cell Test Load | Multi-range electronic load device for SOFC. Supports 5/25A, maximum 10V and 50W, achieving zero volt operation. Compatible with cell and furnace temperature control, gas flow control, cell resistance and IR-free voltage measurement using current interruption method, EIS and HFR measurement. Equipped with safety features such as automatic shutdown and N₂ purge in case of abnormalities. |
| Scribner 740 Membrane Conductivity Measurement System | An integrated system for accurately measuring the ionic conductivity and resistance of polymer electrolyte membranes (PEM). It precisely controls temperature, humidity, gas composition, and pressure, and is capable of measuring conductivity in both in-plane and thickness directions. It is suitable for evaluating fuel cell and water electrolysis materials, comparing ionomers, and conducting durability studies. |
| Scribner cell fixtures and accessories | A lineup of various fixtures for PEM, AEM, DMFC, liquid fuel cells, and redox flow batteries (RFB) is available. These fixtures support high-precision gas and liquid supply, low-resistance connections, and temperature control, aiding in the performance evaluation and research and development of fuel cells and RFBs. The fixtures for RFBs are constructed with excellent corrosion and chemical resistance. |
| 857 Type Redox Flow Battery Evaluation System | An integrated evaluation system for redox flow batteries and electrochemical flow research. Equipped with a high-precision potentiostat, EIS/HFR, SOC measurement, and control of electrolyte flow rate and temperature. Supports impedance measurement from 1 mHz to 10 kHz, flow control from 1 to 1,000 mL/min, and temperature control up to 50°C, allowing for centralized control of charging, discharging, and measurements from a PC. |
| 580 and 585 type charge and discharge measurement systems | High-precision charge and discharge system for research and development of secondary batteries. Model 580 supports a maximum of ±1A, while model 585 supports a maximum of ±5A (±20A in 4-channel parallel mode). It is compatible with 5-terminal and 6-terminal measurements, CC/CV/CC-CV/CP control, impedance measurement, and can be linked with a constant temperature chamber, supporting material evaluation, degradation analysis, and performance evaluation. |
Company information
We are the agent for Metrohm Autolab in the Netherlands in Japan. In Japan, we engage in the sales of AUTOLAB equipment and electrode & cell accessories, customer training, equipment maintenance, and technical support. We specialize in providing support for electrochemical technology. Please feel free to contact us if you have any requests. TEL: 047-344-8558 FAX: 047-344-8108 http://www.autolabj.com e-mail: sales@autolabj.com