It is a load cell converter with a 4-20mA current output.
This is a load cell converter with a 4-20mA current output. The measurement range is unidirectional, from no load to +FS load. An optional 0.8-4.0V voltage output is also available.
Inquire About This Product
basic information
Compatible load cell resistance value: 350Ω Built-in power supply for load cell: +3.89V±5% / 12mA max Sensitivity adjustment range: 1mV/V to 3mV/V Measurement range: No load to +FS load Current output: 4mA (no load) to 20mA (+FS load) Compatible load resistance for current output: 100Ω max (recommended value 50Ω) Current output response frequency: 120Hz (-3dB), standard value at sensitivity = 1mV/V Current output residual noise: 0.15mV rms, standard value at load resistance 100Ω, sensitivity = 1mV/V Voltage output (optional): +0.8V (no load) to +4.0V (+FS load) Compatible load resistance for voltage output: 10kΩ or more (output resistance 100Ω built-in) Voltage output response frequency: 100Hz (-3dB), standard value at sensitivity = 1mV/V Voltage output residual noise: 0.3mV rms, standard value at sensitivity = 1mV/V Relative error between voltage output and current output: within ±3% Offset adjustment range: ±10% of full scale Power supply: +5V±0.2V / 60mA max Dimensions: 60×40×12
Price information
Price including tax: ¥8,250
Delivery Time
※Please contact us.
Applications/Examples of results
It is ideal for applications where the measurement location with the load cell and the control circuit are far apart and a current output type is required.
catalog(1)
Download All CatalogsCompany information
We specialize in the development of measurement instruments as systems, including software, based on analog circuit design.