Even if the pulse air is being injected normally, it does not necessarily mean that all the dust on the filter cloth has been sufficiently removed.
The fact that the pulse cleaning is functioning normally and that dust is being sufficiently removed are two separate issues. In biomass power plants and factories using pulse jet bag filter dust collectors, even with repeated pulse cleaning, there may be residual dust on some parts of the filter cloth. Especially in conventional venturi-type retainers, a negative pressure can occur at the top of the filter cloth during pulse injection, which may prevent the cloth from expanding sufficiently and result in inadequate dust removal. Such insufficient dust removal can potentially affect the rise in differential pressure, increased load on the blower, and the frequency of filter cloth replacement. At Sō Village Consultant, we will check the operating conditions of existing equipment, the pulse cleaning mechanism, and the structure of the retainer to consider possibilities for improvement. Key confirmation items: - Supply pressure of pulse air - Pulse injection time and injection interval - Condition of solenoid valves, diaphragm valves, and injection nozzles - Expansion and dust removal condition up to the top of the filter cloth - Trends in differential pressure and operating load As one of the improvement measures, we will also consider dust removal enhancement using cone-type retainers manufactured by Shinkō Industries. Before repeatedly updating equipment or replacing filter cloths, why not check if the existing equipment is performing to its original capacity?
Inquire About This Product
basic information
Subject: Pulse Jet Type Bag Filter Dust Collector Target Equipment: Existing dust collection equipment in biomass power plants and factories Discussion Points: Confirmation of pulse cleaning status, retainer structure, differential pressure, blower load, and filter cloth replacement history Improvement Methods: Review of operating conditions, discharge mechanism, and retainer structure based on current diagnosis *The effectiveness of improvements varies depending on equipment specifications, operating conditions, and dust characteristics.
Price information
Price: Individual Consultation / Estimate
Delivery Time
※Delivery date: Individual adjustments based on improvement details and equipment conditions.
Applications/Examples of results
Review of improvements for insufficient cleaning of existing bug filters, increased differential pressure, clogging of filter cloth, blower load, and filter cloth replacement costs.
Detailed information
-

Even if the pulse cleaning is functioning normally, it does not necessarily mean that all the dust on the filter cloth has been sufficiently removed. This diagram organizes the factors that can lead to insufficient dust removal, such as the supply conditions of the pulse air, the injection mechanism, and the structure of the filter cloth and retainer. If the differential pressure is high and there is no improvement even after replacing the filter cloth, it is important to check not only the cleaning conditions but also the expansion state of the filter cloth and the structure of the retainer.
-

We are comparing the movement of the filter cloth during pulse cleaning. In conventional venturi systems, a negative pressure is generated at the top of the filter cloth, which may not expand sufficiently. The cone-type retainer promotes expansion from the top of the filter cloth, improving the removal of dust.
Company information
Sora Village Consultant is a business that finds improvement opportunities buried within existing equipment at factories and power plants, leading to energy savings and cost reductions. We emphasize the importance of confirming whether the current equipment is performing to its original capacity before deciding on equipment upgrades. Currently, we are focusing on reducing pressure loss and improving discharge performance with cone-type retainers in pulse jet bag filter dust collectors. We not only consider the technical feasibility of improvements but also assess their impact on annual electricity costs and maintenance expenses, supporting equipment managers in proposing improvements to management.




![[Case Studies / Customer Testimonials] Nara Prefecture: Hotel](https://image.mono.ipros.com/public/product/image/a16/2000718688/IPROS25279805851508665976.png?w=280&h=280)

![[Processing stability, removal of pressurized flotation devices, etc.] Improvement of wastewater treatment facility at chicken meat primary processing plant.](https://image.mono.ipros.com/public/product/image/245/2000695116/IPROS51420521977897336349.jpeg?w=280&h=280)
![[Free Consultation for Electronic Device Manufacturing] Improving Yield in the Manufacturing Process](https://image.mono.ipros.com/public/product/image/2116324/IPROS16462119352443689486.png?w=280&h=280)
![[Usage Example] Bug Filter Replacement Work](https://image.mono.ipros.com/public/product/image/2074492/IPROS13872573921720365251.jpg?w=280&h=280)