Data diode "OWCD" Let's protect the core from unauthorized intrusions!
One-way communication restriction device data diode OWCD
Frequent serious information leaks: Are we able to prevent intrusions? What is the "last boundary" required for all networks in the AI era?
Various companies are experiencing a continuous stream of "data leaks." Finally, it has occurred even at the national research institute "Fugaku," and vigilance against cyber threats is on the rise. The information-stealing malware (infostealer), which is the first step in intrusion, collects information from devices and sends only the useful information for intrusion to AI, which then instructs the next steps. This process is said to take about a minute, and it is clever enough to evade communication monitoring. If deep penetration is allowed, attackers can cause damage at any time, potentially leading to serious consequences such as business shutdowns. Web services for external use are accessible to anyone, making it difficult to implement zero trust and intrusion countermeasures. Surprisingly, cloud services are vulnerable to new types of attacks because the management responsibility lies with the user. Intrusions often start from these points, and information leaks occur because there are no boundary restrictions internally. Once breached, business continuity is at risk, and deep internal penetration can occur. OWCD physically isolates communication in one direction, firmly protecting the boundary and preventing intrusion. There is an explanatory video at the related link below! This technology is patented by Mitsubishi Heavy Industries, Ltd.
Inquire About This Product
basic information
In recent years, while Zero Trust security has gained attention, there is a growing misunderstanding that "perimeter defense is outdated" and "the perimeter is unnecessary." However, Zero Trust is a strong measure against lateral movement and the upgrading of authentication privileges, but its essence is not to "discard the perimeter," but rather to "not place trust solely in the perimeter." This does not mean that the perimeter is unnecessary. Rather, the perimeter should be "strengthened on the premise of not trusting it." A data diode is structured to connect a cable in one direction only to a circuit that is physically disconnected, completely eliminating reverse pathways. The "OWCD" does not allow any communication to flow in the reverse direction, physically neutralizing attacks. Exploits of vulnerabilities or attacks via remote accounts are also rendered ineffective, achieving a risk reduction equivalent to network separation. - Detailed design of security policies → Significant reduction (unidirectional, so unnecessary) - Vulnerability and intrusion vulnerability testing → Removal (unnecessary due to physical isolation) - Operation maintenance and monitoring design → Significant reduction (unnecessary as no configuration changes occur after operation begins) This is an intrusion countermeasure that can be implemented immediately. Please contact us via the related link above.
Price information
The OWCD's "method of purchasing equipment" is unique, but the difficulty of network design is equivalent to "setting up an internal file sharing server." 1: Centralize the output data (data to be sent outside). 2: Properly position the PCs for file (data) transfer, PC-1 and PC-2. 3: Completely skip the security testing. The only communication confirmation is at the same level as a general file transfer test to check if the data sent from the field reaches the external server. 4: Freeze (static) the operational manual. There is no need for emergency change flows for patch application procedures or rules. Please compare it with FW/GW.
Price range
P5
Delivery Time
※Although it is made-to-order, there are also items available for immediate delivery. Please contact us via the related link above.
Applications/Examples of results
IT → Internet, OT → If communication can be restricted in one direction between IT and OT, and for each device, it can be used anywhere. This time, we introduced the "Database ⇒ Customer-provided (Display) Information Update Circuit to Web Server," but it is also used in various ways, such as: - Segmentation from the most critical infrastructure segments - Securing communication in government agencies, data file transfers - Circuits for sending production data from OT systems to IT systems in the supply chain - Information distribution circuits from medical databases to insurance claim receipt systems - Information dissemination via email (also for sending predictive prevention information). I can't share much, but it is being utilized for the defense of critical infrastructure that is important to everyone. The notion of "Our company is small..." is no longer relevant. In the UK, four small-scale thermal power plants were breached, and water supply facilities have also been compromised. Once seen as infrastructure, everyone is a target; the supply chain is also infrastructure. Having holes drilled down to the core and leaking information is a fatal blow. Please use OWCD as the last bastion of multi-layered defense to protect your core by safeguarding critical and essential infrastructure. Please contact us via the related links above.
Detailed information
-

This is the first product of the data diode "OWCD," the OWCD2. It is a general-purpose model with a communication bandwidth of 100 Mbps. Recently, the communication volume used by everyone has increased, leading to capacity shortages, but it is still very much in active use for intrusion countermeasures from the Syslog collection route, among other things.
catalog(1)
Download All CatalogsCompany information
Our company is a member of the Mitsubishi Heavy Industries Group, serving as a design technology partner for Mitsubishi Heavy Industries, where we engage in planning and mechanical design for prime movers (steam turbines/boilers, gas turbines, water turbines), pumps, and various plants, as well as instrumentation control system planning and electrical design. In order to meet the increasingly diverse and sophisticated needs of our customers, we will continue to challenge ourselves to improve our technological capabilities, streamline operations, and reduce costs based on the trust we have built with users. Through this, we are developing activities that contribute to society by providing the products and engineering capabilities we have cultivated so far to everyone. Alongside the sale of products related to IoT, manufacturing DX, and on-site monitoring/condition monitoring, we will focus on custom orders, customization, and system construction to realize your ideas. We encourage you to consider utilizing our services. https://eng.power.mhi.com





![[Data] Data diodes provide cybersecurity for substations.](https://image.mono.ipros.com/public/product/image/2050212/IPROS1060237848567759815.jpg?w=280&h=280)



![[Information] Latest Trends and Examples of Data Diodes](https://image.mono.ipros.com/public/product/image/2050212/IPROS14803315463455232258.jpg?w=280&h=280)



