List of Safety Equipment products
- classification:Safety Equipment
4021~4035 item / All 4139 items
Reduce the workload from handling heavy objects! Here are five case studies that solved customer challenges! We are also accepting free consultations and tests tailored to your work!
- Other conveying machines
Strong cold wind from room temperature to -13°C! Depending on the usage environment, you can choose between the combo type or the separate type!
- Cooling system
April 10, 2024 (Wednesday) to April 12, 2024 (Friday) Notice of Participation in Nagoya Manufacturing World 2024
Sanwa Shiki Ventilator Co., Ltd. will be exhibiting at the 2024 Monozukuri World (Nagoya) held at Port Messe Nagoya. We will also be showcasing our large cooling fans and cool/warm ambient products. Date: April 10, 2024 - April 12, 2024 Opening: 10:00 AM Location: Nagoya Port Messe (Exhibition Hall 1) *Our booth: 19-1 We would be grateful if you could visit us if you have the time.
The installation of the ceiling-mounted fire alarm can be easily done from indoors. / New product for ceiling-mounted fire alarm brackets.
- LAN construction and wiring work
- PBX/IP phone
- Other safety equipment
A new product for easily inspecting and connecting junctions of ceiling wires from indoors / Junction inspection opening.
■Overview of the Joint Inspection Opening 1. It consists of a mounting frame and a cover, with the ceiling finishing material fitted into the cover. The mounting frame is attached to the ceiling finishing material, and a stand is combined with the supporting material of the mounting frame, with a joint box mounted on the upper part of the stand. 3. A hole is drilled from inside the room into the ceiling finishing material, and the main body is fitted and installed into that hole. It can be installed neatly and easily without any discomfort. 4. It is installed on the ceiling surface at the location of the connection (joint) of the electrical wires in the ceiling space from inside the room. 5. The cover is opened to connect the electrical wires in the ceiling space. Closing the cover completes the process. Additionally, the cover can be opened for confirmation and inspection of the connection points. Connection replacement work can also be performed. 6. By providing a joint inspection opening in the ceiling, it allows for the inspection of the connections (joints) of the electrical wires in the ceiling space from inside the room. Furthermore, it enables connection replacement work for miswiring or connection failures without damaging the ceiling finishing material. 7. By periodically inspecting the connection points of the electrical wires in the ceiling space, it is possible to prevent equipment damage and fires caused by abnormal heat due to overload or connection failures.
Beyond common sense irradiation distance" and "Surprisingly compact and lightweight body
- Other work tools
- Other safety equipment
New products have been uploaded!
Newly listed 2 items ↓↓↓↓↓↓↓↓ 【Heat exchanger using Teflon tube from Junkosha: 'Fluoroex'] 【Flashlight-type searchlight: 'Night Hunter'] In particular, the Night Hunter has been very effective for maintenance inspections of transmission towers (distribution towers) as a disaster prevention measure after the earthquake. It allows inspections to be conducted from the ground with a searchlight, eliminating the need for personnel to climb the towers! It may also be useful for inspecting roller coasters at amusement parks.
Expansion of installation location variations. Double visibility with LED and reflector.
- Other safety equipment
- Other safety and hygiene products
Super high visibility. Achieved approximately four times the reflective performance with front hardness.
- Other safety equipment
- Other safety and hygiene products
We have responded to the request that dual-sided use is not necessary in multiple diagonal line sections under the jurisdiction of the Ministry of Land, Infrastructure, Transport and Tourism.
- Other safety equipment
- Other safety and hygiene products
A compact design that doesn't create a sense of pressure even when installed on guardrails, along with excellent reflective performance!
- Other safety equipment
- Other safety and hygiene products
It is a large rear reflector that meets the technical requirements of "ECE R70".
- Other safety equipment
- Other safety and hygiene products
By adopting newly developed lenses, we have achieved 3 to 8 times the reflection performance compared to conventional products.
- Other safety equipment
- Other safety and hygiene products
Epoxy resin material was injected inside to improve strength.
- Other safety equipment
- Other safety and hygiene products
Introducing the stop display boards RR-1900TS and RR-1900EC.
- Other safety equipment
- Other safety and hygiene products
You can easily, reliably, and more safely lock out the air supply port.
- Wiring materials
- Other work tools
- Other safety equipment
Code lockout, plug lockout, outlet lockout, etc.
- Wiring materials
- Other work tools
- Other safety equipment
Used when a large number of workers need to enter a work area that requires lockout.
- Wiring materials
- Other work tools
- Other safety equipment
This is a lockout kit for electrical work, maintenance, and power control.
- Wiring materials
- Other work tools
- Other safety equipment
Stainless type, non-conductive, high security, laminated type, etc.
- Wiring materials
- Other work tools
- Other safety equipment