List of Testing Equipment and Devices products
- classification:Testing Equipment and Devices
2281~2310 item / All 6714 items
Presentation of explanatory materials on JIS and ISO standards. We propose suitable safety barriers from a rich product series! Free rental of demo kits.
- Other safety and hygiene products
You can download a free booklet that introduces the uses, structures, and examples of various types of frames.
- Other machine tools
- Solar power generator
- Other energy equipment
Ideal for tests such as destruction strength, tensile, compression, connector insertion and removal, and peeling.
- Testing Equipment and Devices
An automatic spring testing machine that can register up to 100 different item numbers with various conditions!
- Testing Equipment and Devices
The transport test can accommodate almost all test schedules specified in the ASTM D 4169 evaluation test method general rules.
- Vibration Testing
Contents and Key Points of ASTM D642-25 Standard Revision
The American Society for Testing and Materials (ASTM) has announced the latest version of ASTM D642 (Standard Test Method for Compression Resistance of Shipping Containers, Components, and Unit Loads), ASTM D642-25. This revision aims to enhance the consistency and accuracy of the testing. Background of the Revision - Improvement of accuracy, reproducibility, and reliability of compression tests - Strengthening of consistency among standards - Ensuring consistency in practical applications Main Changes 1. Addition of related standards due to strengthened consistency among standards: ASTM D5118 (Specification for Fiberboard Shipping Boxes) ASTM D6804 (Guide for Shipping Containers) 2. New requirements for movable platens: It is now mandatory to drive the platen at a constant speed of 0.5 inches per minute (12.7 mm ± 2.5 mm/min). This change aims to improve testing accuracy. 3. Direction recording during testing: It is now required to record the test direction during the test. 4. Update of Appendix X1 (X1.7): Clarification of flap handling methods for boxes: "Flaps should be bent directly to the sealing position or folded 180° and then returned to the normal sealing position." Impact and Benefits - Improved testing accuracy and reproducibility - Strengthened consistency among standards - Enhanced reliability of packaging tests
DC6 is a simulation test for transporting palletized goods either fully loaded or in mixed cargo on a truck.
- Vibration Testing
DC3 is a simulation test for truck transportation of mixed cargo small shipments that do not use pallets or skids.
- Vibration Testing
DC2 allows users to specify test conditions. It enables the flexible assembly of ten types of hazards to configure the entire test according to the transport environment.
- Vibration Testing
DC13 is a simulation test for air and truck transportation of small packages weighing 68.1 kg or less.
- Impact Test
Contents and Key Points of ASTM D642-25 Standard Revision
The American Society for Testing and Materials (ASTM) has announced the latest version of ASTM D642 (Standard Test Method for Compression Resistance of Shipping Containers, Components, and Unit Loads), ASTM D642-25. This revision aims to enhance the consistency and accuracy of the testing. Background of the Revision - Improvement of accuracy, reproducibility, and reliability of compression tests - Strengthening of consistency among standards - Ensuring consistency in practical applications Main Changes 1. Addition of related standards due to strengthened consistency among standards: ASTM D5118 (Specification for Fiberboard Shipping Boxes) ASTM D6804 (Guide for Shipping Containers) 2. New requirements for movable platens: It is now mandatory to drive the platen at a constant speed of 0.5 inches per minute (12.7 mm ± 2.5 mm/min). This change aims to improve testing accuracy. 3. Direction recording during testing: It is now required to record the test direction during the test. 4. Update of Appendix X1 (X1.7): Clarification of flap handling methods for boxes: "Flaps should be bent directly to the sealing position or folded 180° and then returned to the normal sealing position." Impact and Benefits - Improved testing accuracy and reproducibility - Strengthened consistency among standards - Enhanced reliability of packaging tests
[Transport Test] A series of packaging tests will be conducted in accordance with the test sequence specified in ISTA 7D.
- Thermostatic chamber
We will conduct a series of packaging tests in accordance with the test sequences specified in ASTM D4169 and ASTM D7386.
- Vibration Testing
Contents and Key Points of ASTM D642-25 Standard Revision
The American Society for Testing and Materials (ASTM) has announced the latest version of ASTM D642 (Standard Test Method for Compression Resistance of Shipping Containers, Components, and Unit Loads), ASTM D642-25. This revision aims to enhance the consistency and accuracy of the testing. Background of the Revision - Improvement of accuracy, reproducibility, and reliability of compression tests - Strengthening of consistency among standards - Ensuring consistency in practical applications Main Changes 1. Addition of related standards due to strengthened consistency among standards: ASTM D5118 (Specification for Fiberboard Shipping Boxes) ASTM D6804 (Guide for Shipping Containers) 2. New requirements for movable platens: It is now mandatory to drive the platen at a constant speed of 0.5 inches per minute (12.7 mm ± 2.5 mm/min). This change aims to improve testing accuracy. 3. Direction recording during testing: It is now required to record the test direction during the test. 4. Update of Appendix X1 (X1.7): Clarification of flap handling methods for boxes: "Flaps should be bent directly to the sealing position or folded 180° and then returned to the normal sealing position." Impact and Benefits - Improved testing accuracy and reproducibility - Strengthened consistency among standards - Enhanced reliability of packaging tests
We are accumulating the know-how necessary for data extraction as a basis for selection criteria!
- Testing Equipment and Devices
- Other contract services
Store the compound in a nitrogen environment to maintain concentration, solubility, and activity. Application notes are being distributed.
- Testing Equipment and Devices
Our company conducts the JIS C 60068-2-64 wideband random vibration test.
- Environmental Test Equipment
Our company conducts environmental testing, including temperature and humidity combination (cycle) tests, as well as temperature and humidity tests based on customer-specified conditions.
- Environmental Test Equipment
Our company conducts environmental testing according to JIS C 60068-2-30 - Temperature and Humidity Cycle Testing, as well as temperature and humidity testing based on customer-specified conditions.
- Environmental Test Equipment
◤ Shock Test (Sine Half Wave / Trapezoidal Wave) ◢ It is possible to conduct a shock test with a long duration sine half wave while wearing elastomers.
- Vibration Testing
Introducing the equipment we have, such as single-axis powerful winding machines and CNC tapping centers!
- Milling machine
- Drying Equipment
- Testing Equipment and Devices
[Transport Test] We will conduct the packaging tests specified in ISTA 6 SAMSCLUB.
- Impact Test
[Transport Test] A series of packaging tests will be conducted in accordance with the test sequence specified in ISTA 3F.
- Impact Test
[Transport Test] A series of packaging tests will be conducted in accordance with the test sequence specified in ISTA 3E.
- Impact Test
[Transport Test] A series of packaging tests will be conducted in accordance with the test sequence specified in ISTA 3B.
- Impact Test
[Transport Test] A series of packaging tests will be conducted in accordance with the test sequence specified in ISTA 3A.
- Impact Test
[Transport Test] We will conduct the packaging tests specified in ISTA 3A Small.
- Impact Test
[Transport Test] A series of packaging tests will be conducted in accordance with the test sequence specified in ISTA 2C.
- Impact Test
[Transport Test] A series of packaging tests will be conducted in accordance with the test sequence specified in ISTA 2B.
- Impact Test
[Transport Test] A series of packaging tests will be conducted in accordance with the test sequence specified in ISTA 2A.
- Impact Test