List of LAN construction and wiring work products
- classification:LAN construction and wiring work
871~885 item / All 915 items
For those who have isolators. Achieving high chemical resistance and workability. Low cost and short delivery times are also possible for glove box and isolator gloves.
- Work gloves
Notice of participation in 'INTERPHEX Week Tokyo' from May 20 (Wednesday) to May 22 (Friday), 2026.
Ito Corporation will be exhibiting at "INTERPHEX Week Tokyo" held at Makuhari Messe. This exhibition is the largest in Japan, showcasing a wide range of products and services related to the research and manufacturing of pharmaceuticals, cosmetics, and regenerative medicine from 25 countries and regions around the world. Pharmaceutical and cosmetic manufacturers, as well as regenerative medicine companies, will be attending from all over the globe. We will be showcasing "Gloves for Glove Boxes/Isolators" manufactured by Tron Power. We look forward to your visit.
The installation of the ceiling-mounted fire alarm can be easily done from indoors. / New product for ceiling-mounted fire alarm brackets.
- LAN construction and wiring work
- PBX/IP phone
- Other safety equipment
A new product for easily inspecting and connecting junctions of ceiling wires from indoors / Junction inspection opening.
■Overview of the Joint Inspection Opening 1. It consists of a mounting frame and a cover, with the ceiling finishing material fitted into the cover. The mounting frame is attached to the ceiling finishing material, and a stand is combined with the supporting material of the mounting frame, with a joint box mounted on the upper part of the stand. 3. A hole is drilled from inside the room into the ceiling finishing material, and the main body is fitted and installed into that hole. It can be installed neatly and easily without any discomfort. 4. It is installed on the ceiling surface at the location of the connection (joint) of the electrical wires in the ceiling space from inside the room. 5. The cover is opened to connect the electrical wires in the ceiling space. Closing the cover completes the process. Additionally, the cover can be opened for confirmation and inspection of the connection points. Connection replacement work can also be performed. 6. By providing a joint inspection opening in the ceiling, it allows for the inspection of the connections (joints) of the electrical wires in the ceiling space from inside the room. Furthermore, it enables connection replacement work for miswiring or connection failures without damaging the ceiling finishing material. 7. By periodically inspecting the connection points of the electrical wires in the ceiling space, it is possible to prevent equipment damage and fires caused by abnormal heat due to overload or connection failures.
New product for easily inspecting and connecting junctions of ceiling wires from indoors / Junction inspection opening.
- LAN construction and wiring work
- PBX/IP phone
- Other network tools
The installation of the ceiling-mounted fire alarm can be easily done from indoors. / New product for ceiling-mounted fire alarm brackets.
■Overview of Ceiling Space Fire Alarm Device 1. It consists of a mounting frame and a cover, with the ceiling finishing material fitted into the cover, and a stand combined with the mounting frame, forming a ceiling space fire alarm device. 2. The ceiling space fire alarm device is installed on the ceiling finishing material, with a wireless linked fire alarm unit attached to the top of the stand, and the main unit attached to the cover, allowing for the detection of fires in both the ceiling space and the room simultaneously. 3. A fire alarm can be installed on the top of the stand, and an additional buzzer can be attached to the cover, with signal lines connecting the devices. 4. A fire alarm unit can be attached to the top of the stand, and the main unit can be attached to the cover. A hole is drilled from the room into the ceiling finishing material, and the ceiling space fire alarm device is fitted into that hole, allowing for easy and aesthetically pleasing installation without discomfort. 5. Fire testing and inspection of the main unit attached to the cover and the fire alarm unit in the ceiling space can be easily performed from inside the room. 6. For example, if a fire occurs in the ceiling space of a house, the ceiling space fire alarm (sub-unit) detects the fire and sounds the alarm, while the fire alarm (main unit) in the cover also sounds the alarm inside the room. This allows for early detection of fires in the ceiling space.
New product of sealing unit that facilitates electrical work for building renovations and extensions.
- LAN construction and wiring work
- PBX/IP phone
- Other network tools
A new product for easily inspecting and connecting junctions of ceiling wires from indoors / Junction inspection opening.
■Overview of the Joint Inspection Opening 1. It consists of a mounting frame and a cover, with the ceiling finishing material fitted into the cover. The mounting frame is attached to the ceiling finishing material, and a stand is combined with the supporting material of the mounting frame, with a joint box mounted on the upper part of the stand. 3. A hole is drilled from inside the room into the ceiling finishing material, and the main body is fitted and installed into that hole. It can be installed neatly and easily without any discomfort. 4. It is installed on the ceiling surface at the location of the connection (joint) of the electrical wires in the ceiling space from inside the room. 5. The cover is opened to connect the electrical wires in the ceiling space. Closing the cover completes the process. Additionally, the cover can be opened for confirmation and inspection of the connection points. Connection replacement work can also be performed. 6. By providing a joint inspection opening in the ceiling, it allows for the inspection of the connections (joints) of the electrical wires in the ceiling space from inside the room. Furthermore, it enables connection replacement work for miswiring or connection failures without damaging the ceiling finishing material. 7. By periodically inspecting the connection points of the electrical wires in the ceiling space, it is possible to prevent equipment damage and fires caused by abnormal heat due to overload or connection failures.
Fire safety equipment installation for new construction and renovations can be done easily / Sealing stand construction technology
- LAN construction and wiring work
- PBX/IP phone
- Other network tools
A new product for easily inspecting and connecting junctions of ceiling wires from indoors / Junction inspection opening.
■Overview of the Joint Inspection Opening 1. It consists of a mounting frame and a cover, with the ceiling finishing material fitted into the cover. The mounting frame is attached to the ceiling finishing material, and a stand is combined with the supporting material of the mounting frame, with a joint box mounted on the upper part of the stand. 3. A hole is drilled from inside the room into the ceiling finishing material, and the main body is fitted and installed into that hole. It can be installed neatly and easily without any discomfort. 4. It is installed on the ceiling surface at the location of the connection (joint) of the electrical wires in the ceiling space from inside the room. 5. The cover is opened to connect the electrical wires in the ceiling space. Closing the cover completes the process. Additionally, the cover can be opened for confirmation and inspection of the connection points. Connection replacement work can also be performed. 6. By providing a joint inspection opening in the ceiling, it allows for the inspection of the connections (joints) of the electrical wires in the ceiling space from inside the room. Furthermore, it enables connection replacement work for miswiring or connection failures without damaging the ceiling finishing material. 7. By periodically inspecting the connection points of the electrical wires in the ceiling space, it is possible to prevent equipment damage and fires caused by abnormal heat due to overload or connection failures.
Installation and inspection of ceiling-mounted fire detectors can be easily done from indoors / New product for ceiling stands.
- LAN construction and wiring work
- PBX/IP phone
- Other network tools
A new product for easily inspecting and connecting junctions of ceiling wires from indoors / Junction inspection opening.
■Overview of the Joint Inspection Opening 1. It consists of a mounting frame and a cover, with the ceiling finishing material fitted into the cover. The mounting frame is attached to the ceiling finishing material, and a stand is combined with the supporting material of the mounting frame, with a joint box mounted on the upper part of the stand. 3. A hole is drilled from inside the room into the ceiling finishing material, and the main body is fitted and installed into that hole. It can be installed neatly and easily without any discomfort. 4. It is installed on the ceiling surface at the location of the connection (joint) of the electrical wires in the ceiling space from inside the room. 5. The cover is opened to connect the electrical wires in the ceiling space. Closing the cover completes the process. Additionally, the cover can be opened for confirmation and inspection of the connection points. Connection replacement work can also be performed. 6. By providing a joint inspection opening in the ceiling, it allows for the inspection of the connections (joints) of the electrical wires in the ceiling space from inside the room. Furthermore, it enables connection replacement work for miswiring or connection failures without damaging the ceiling finishing material. 7. By periodically inspecting the connection points of the electrical wires in the ceiling space, it is possible to prevent equipment damage and fires caused by abnormal heat due to overload or connection failures.
Electrical work for new construction and renovations can be done easily / Ceiling hole construction technology.
- LAN construction and wiring work
- PBX/IP phone
- Other network tools
The installation of the ceiling-mounted fire alarm can be easily done from indoors. / New product for ceiling-mounted fire alarm brackets.
■Overview of Ceiling Space Fire Alarm Device 1. It consists of a mounting frame and a cover, with the ceiling finishing material fitted into the cover, and a stand combined with the mounting frame, forming a ceiling space fire alarm device. 2. The ceiling space fire alarm device is installed on the ceiling finishing material, with a wireless linked fire alarm unit attached to the top of the stand, and the main unit attached to the cover, allowing for the detection of fires in both the ceiling space and the room simultaneously. 3. A fire alarm can be installed on the top of the stand, and an additional buzzer can be attached to the cover, with signal lines connecting the devices. 4. A fire alarm unit can be attached to the top of the stand, and the main unit can be attached to the cover. A hole is drilled from the room into the ceiling finishing material, and the ceiling space fire alarm device is fitted into that hole, allowing for easy and aesthetically pleasing installation without discomfort. 5. Fire testing and inspection of the main unit attached to the cover and the fire alarm unit in the ceiling space can be easily performed from inside the room. 6. For example, if a fire occurs in the ceiling space of a house, the ceiling space fire alarm (sub-unit) detects the fire and sounds the alarm, while the fire alarm (main unit) in the cover also sounds the alarm inside the room. This allows for early detection of fires in the ceiling space.
Round inspection opening/sealing hole that can be easily installed on the ceiling.
- LAN construction and wiring work
- PBX/IP phone
- Other network tools
A new product for easily inspecting and connecting junctions of ceiling wires from indoors / Junction inspection opening.
■Overview of the Joint Inspection Opening 1. It consists of a mounting frame and a cover, with the ceiling finishing material fitted into the cover. The mounting frame is attached to the ceiling finishing material, and a stand is combined with the supporting material of the mounting frame, with a joint box mounted on the upper part of the stand. 3. A hole is drilled from inside the room into the ceiling finishing material, and the main body is fitted and installed into that hole. It can be installed neatly and easily without any discomfort. 4. It is installed on the ceiling surface at the location of the connection (joint) of the electrical wires in the ceiling space from inside the room. 5. The cover is opened to connect the electrical wires in the ceiling space. Closing the cover completes the process. Additionally, the cover can be opened for confirmation and inspection of the connection points. Connection replacement work can also be performed. 6. By providing a joint inspection opening in the ceiling, it allows for the inspection of the connections (joints) of the electrical wires in the ceiling space from inside the room. Furthermore, it enables connection replacement work for miswiring or connection failures without damaging the ceiling finishing material. 7. By periodically inspecting the connection points of the electrical wires in the ceiling space, it is possible to prevent equipment damage and fires caused by abnormal heat due to overload or connection failures.
[RoHS compliant] Improved workability with flexible wiring! Enhanced appearance with color-coded wiring!
- Wiring materials
- LAN construction and wiring work
Ideal for inter-base communication in locations with limited installation space or harsh temperature conditions!
- LAN construction and wiring work
- LAN/Optical cable
- cable
Significantly enhance the scalability of optical fiber LAN to 40/100G!
- Optical Connector
- LAN/Optical cable
- LAN construction and wiring work
Standard types that can be used widely, as well as cable ties with weather resistance and flame retardancy.
- Other work tools
- Wiring materials
- LAN construction and wiring work
A lineup of temporary fastening types, push-in types, clamp types, and more!
- Other work tools
- Wiring materials
- LAN construction and wiring work
Protecting connectors in harsh environments such as factories to achieve reliable LAN wiring.
- LAN construction and wiring work
- Wiring materials
It physically ensures the prevention of troubles caused by unauthorized access to networks and USBs.
- Wiring materials
- Other security
- LAN construction and wiring work
Panduit's Category 6A 10Gb wiring system with a proven track record in the LAN wiring market.
- LAN/Optical cable
- LAN construction and wiring work
- Wiring materials