List of Distance measuring device products
- classification:Distance measuring device
46~60 item / All 938 items
Reduce the workload from handling heavy objects! Here are five case studies that solved customer challenges! We are also accepting free consultations and tests tailored to your work!
- Other conveying machines
Strong cold wind from room temperature to -13°C! Depending on the usage environment, you can choose between the combo type or the separate type!
- Cooling system
April 10, 2024 (Wednesday) to April 12, 2024 (Friday) Notice of Participation in Nagoya Manufacturing World 2024
Sanwa Shiki Ventilator Co., Ltd. will be exhibiting at the 2024 Monozukuri World (Nagoya) held at Port Messe Nagoya. We will also be showcasing our large cooling fans and cool/warm ambient products. Date: April 10, 2024 - April 12, 2024 Opening: 10:00 AM Location: Nagoya Port Messe (Exhibition Hall 1) *Our booth: 19-1 We would be grateful if you could visit us if you have the time.
Linear encoder, suitable for replacement from lightweight magnetic incremental scales such as optical types (VP-90 Easy Scale, etc.).
- Distance measuring device
- Sensors
Proposal for replacement of Keyence Corporation's "VP-90".
Guide to Linear Encoders Due to the discontinuation of the Keyence "VP-90," Makome Laboratory is proposing replacement products. As a replacement for the Keyence "VP-90," Makome Laboratory recommends the magnetic linear encoder "SI-140" system. The "SI-140" system utilizes magnetism to measure a scale that is magnetized alternately and evenly with N and S poles, in a non-contact manner. Because it uses magnetism, it can measure lengths without being affected by non-magnetic materials. The head has a protection structure rated IP67 (compliant with IEC standards). The output is in A and B phase with a resolution of 0.1mm. When using an incremental measurement device with a 4x multiplier, it can be used at 0.025mm. The detection distance between the head and the scale is 4±3mm (1 to 7mm), allowing for some variation in distance. The output circuit is a MOS FET open-drain output, which can be extended up to 5m. Additionally, there is a separate line driver output type that can be extended up to 100m. *The MOS FET open-drain is almost equivalent to an NPN transistor output. Please contact us for evaluation samples.
VICIVISION is the optimal solution for measuring extremely small details without contact.
- shaft
- Distance measuring device
We will be exhibiting at Mechatrotech Japan 2023.
Dear Sir/Madam, I would like to express my congratulations on the continued prosperity of your company. I sincerely appreciate your exceptional support. We will be exhibiting at the MECT2023 (Mechatrotech Japan 2023). We will be presenting the features and performance of the following products: - Pinhole Detector and Surface Inspection System by ARCK SENSOR, France - Optical Shaft Shape Measuring Machine by VICIvision, Italy We kindly invite you to visit our booth and view our exhibits. Sincerely, October 2023 CB Corporation President Remy Deschastel Details: Event Name: MECT2023 / Mechatrotech Japan 2023 Dates: October 18 (Wednesday) to October 21 (Saturday), 2023 Venue: Port Messe Nagoya, 3rd Exhibition Hall, 3A28 Opening Hours: 10:00 AM to 5:00 PM (until 4:00 PM on the last day)
Ready to use right after purchase! Comes with a display, magnetic encoder "SI-140 Package" length measurement system, also for Kaizen proposals.
- Distance measuring device
Proposal for replacement of Keyence Corporation's "VP-90".
Guide to Linear Encoders Due to the discontinuation of the Keyence "VP-90," Makome Laboratory is proposing replacement products. As a replacement for the Keyence "VP-90," Makome Laboratory recommends the magnetic linear encoder "SI-140" system. The "SI-140" system utilizes magnetism to measure a scale that is magnetized alternately and evenly with N and S poles, in a non-contact manner. Because it uses magnetism, it can measure lengths without being affected by non-magnetic materials. The head has a protection structure rated IP67 (compliant with IEC standards). The output is in A and B phase with a resolution of 0.1mm. When using an incremental measurement device with a 4x multiplier, it can be used at 0.025mm. The detection distance between the head and the scale is 4±3mm (1 to 7mm), allowing for some variation in distance. The output circuit is a MOS FET open-drain output, which can be extended up to 5m. Additionally, there is a separate line driver output type that can be extended up to 100m. *The MOS FET open-drain is almost equivalent to an NPN transistor output. Please contact us for evaluation samples.
Microwave Proximity Sensor: BSS300 (under development) - As a non-contact sensor, it can be widely applied to traffic lights, lighting activation, shutter opening and closing, etc.
- Distance measuring device
- Area Sensor
- Safety Sensors
GNSS receiver tablet device equipped with Windows 10
- Distance measuring device
It is an all-in-one receiver equipped with a rich interface (WiFi, Bluetooth, serial USB, CAN).
- Distance measuring device
360° exclusive. A laser rangefinder that can measure all around. Completely waterproof, red display.
- Distance measuring device
The scale with a vernier allows for precise straight line marking.
- Distance measuring device
High-precision 2D laser scanner capable of measuring in horizontal/vertical directions. Achieves measurements of displacement, strain, subsidence, and erosion that were not possible before. [Demo unit...
- Distance measuring device
High-precision 2D laser scanner capable of measuring in horizontal/vertical directions. Achieves measurements of displacement, strain, subsidence, and wear that were not possible before. [Demo unit av...
- Distance measuring device