List of Chiller products
- classification:Chiller
76~90 item / All 267 items
Achieves high collection efficiency through electrostatic methods. Offers a wide range of products from large to small sizes. Also compatible with water-soluble oil mist.
- air conditioning
Durable PCU-SL and PCU-R that supports -10 to 80°C. Suitable for both cooling and heating! Both series can be used interchangeably according to each site.
- Chiller
[Data Release] We have published "How to Choose a Chiller to Avoid Problems Later"!
When selecting a chiller, it is important to carefully consider the usage conditions, usage situation, and the chiller's functions, performance, and specifications. Neglecting the selection process may result in the chiller not performing as expected after it is put into use, potentially leading to issues with the equipment or the chiller itself. Additionally, the selection of a chiller requires not only the work (cooling target) temperature and heat load but also factors such as the piping lift. Therefore, compared to other equipment and devices, selecting the appropriate chiller model is more challenging and prone to problems. In this volume, we will clearly introduce the method for selecting a chiller. 【Contents (Excerpt)】 ■ Selection Step 1: Determine the temperature of the circulating water ■ Selection Step 2: Decide on the cooling method ■ Selection Step 3: Determine the cooling capacity ■ Selection Step 4: Determine the pump capacity *If you have any questions, please feel free to contact us.
With an ultra-wide range specification of -10℃ to 80℃, it can handle tests that require a variety of temperatures with just one unit.
- Chiller
[Case Study of Solution Proposal] Reducing the number of chillers for testing equipment with diverse temperature requirements! A catalog explained in 6 pages of manga is now available!
We are currently publishing a catalog showcasing examples that are possible only because of Apiste's expertise in both environmental improvement and air conditioning/temperature control. 【Solution Proposal Examples】 ■ Conventional Method - Using two chillers divided into low-temperature and high-temperature ranges ■ Issues - Difficult temperature control due to the use of two chillers - Initial costs for two units - Requires installation space for two units ■ Ideal Condition - One chiller that can handle both low and high-temperature ranges - High-precision water temperature control ■ Apiste's Proposal - Use one ultra-wide range chiller from the PCU-R series, capable of -10℃ to 80℃ ■ Benefits - One chiller covers both low and high-temperature ranges - Achieves temperature control with high precision of ±0.05℃ + Double safety pan structure for peace of mind in case of emergencies + Standard RS232C communication for remote control capability + Use of external temperature sensors allows for cascade control *For more details, please refer to the related product catalog or feel free to contact us.
The Apiste chillers are available in three series: non-Freon, high durability, and ultra-wide range! You can choose the optimal chiller according to your application.
- Chiller
Achieve "heating," "keeping warm," and "cooling" at the desired temperature! In addition to temperature control in the jacket part of the mixer, it supports various applications.
- Temperature and Humidity Control
- Chiller
Achieved a cycle reduction of over 20% compared to the conventional steam method (measured values using the same test mold).
- Chiller
[New Product] The industry's first superheated steam circulation device! We have launched a superheated steam circulation device capable of reaching up to 600℃.
We have launched the industry's first superheated steam circulation device, the "KCS-8078/600." Traditionally, when using high-temperature media, the maximum temperature for thermal media oil was 320°C, but this device can circulate superheated steam at temperatures up to 600°C. Typically, the use of superheated steam requires boilers and softening equipment, but since the water in the built-in tank circulates, no special utilities are needed. Furthermore, our patented heat recovery system achieves approximately 10% energy savings. 【Features】 ■ Circulates superheated steam at 600°C ■ Circulates at low pressure (below 0.1 MPa), eliminating the need for pressure-resistant design in piping and target objects ■ No special utilities such as boilers or softening equipment are required ■ No installation notifications or boiler qualifications are necessary
We propose units designed with customization to meet customer needs and applications, taking into consideration the global environment!
- Chiller
Ideal for temperature regulation of liquids such as pharmaceuticals and food! Custom solutions are also available to meet your needs.
- Chiller
We provide exceptional cooling capacity (up to 600 tons) to support data center thermal management!
- Chiller
- Refrigeration equipment/chiller
Temperature management for painting booths! Easy-to-install container-type cooling tower.
- Chiller
Streamlining plastic molding! Achieving both cooling performance and space-saving.
- Chiller
Optimize the cooling of the welding process to improve productivity.
- Chiller