List of Wastewater/wastewater treatment equipment products

  • classification:Wastewater/wastewater treatment equipment

16~30 item / All 1961 items

Displayed results

It won't break even after 1 million repetitions! A mat switch with reliable operation, high durability, and low price. Suitable for options in machine tools as well. Please consult us about delivery t...

  • Sensors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

We can accommodate high resistance over 10,000 ohms, with diameters ranging from approximately 30 mm to 8 inches, and we also offer thinning and chip processing arrangements!

  • Other semiconductors
  • Processing Contract
  • Wafer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Achieved with simple design and low cost! Polymer coagulant dissolution unit 'JG' that automatically dissolves polymer coagulants continuously.

  • IPROS7484547138355021810.png
  • IPROS93811045360711100134.png
  • 2020-01-23_16h45_17.png
  • jg-img-03.png
  • 2020-01-23_16h45_23.png
  • 2020-01-23_16h45_28.png
  • Wastewater/wastewater treatment equipment
  • Wastewater treatment equipment, technology and maintenance
  • Waste liquid treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
1.png

Introducing the latest information on the polymer coagulant dissolution unit 'JG', which automatically and continuously dissolves polymer coagulants with a simple design and low cost!

The leading company in precision pumps, Takumina, presents the polymer coagulant dissolution unit 'JG'. The 'JG Series' is a unit that automatically and continuously dissolves polymer coagulants such as coagulant aids for wastewater treatment and sludge dewatering aids. By controlling the water level in the dissolution tank, it is possible to continuously supply the dissolved solution from a single tank. The materials used are durable, allowing for long-term use. 【Features】 ■ From manual to automation This is a polymer coagulant dissolution unit for wastewater treatment, including dewatering, coagulation sedimentation, and pressurized flotation. ■ Simple design & low cost Polymer coagulants can be easily fed into the hopper for automatic dissolution. Changing the concentration requires just one timer! The simple structure of the powder feeding mechanism makes maintenance easy and allows for quick responses to any unexpected issues. ■ No dry air required Thanks to the mechanical seal structure, there is no need for dry air supply, and moisture resistance is sufficient. ■ Excellent durability The materials used are highly durable, allowing for long-term use. For more details, please refer to the catalog.

Carbon dioxide pH neutralization treatment system "ALC" capable of handling a large flow rate of 100㎥/h with【safety, reliability, and cost-effectiveness】.

  • IPROS60008566160884181547.jpeg
  • 2.jpg
  • 3.jpg
  • 4.jpg
  • Water treatment equipment
  • Wastewater/wastewater treatment equipment
  • Other pumps

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Takumina] Safe, reliable, and economical with carbon dioxide! We have released the latest information on the pH neutralization treatment device 'ALC' that supports a large flow rate of 100㎥/h.

The "ALC" pH neutralization treatment device with a large flow capacity of 100 m³/h from Takumina, the leading company in precision pumps. It efficiently and safely treats alkaline wastewater through inline pH neutralization using carbon dioxide. ■□■ Main Features ■□■ ☑ Feedback system incorporating an industrial pH meter This allows for more accurate injection of carbon dioxide while simultaneously preventing excessive injection, thereby reducing running costs. ☑ Significantly improved mixing efficiency of raw water and carbon dioxide By using a static mixer, the amount of carbon dioxide used is minimized, enabling extremely quick neutralization treatment inline. ☑ Space-saving achieved through Takumina's unique internal control technology The device is integrated into a common frame, making relocation possible. Operation and control are simple, and maintenance is easy. ■□■ Main Applications ■□■ ■ Wastewater from ready-mixed concrete manufacturing plants ■ Boiler cleaning wastewater ■ Wastewater from bottle washing in beverage factories ■ Drainage from road and bridge construction ■ Other alkaline wastewater For more details, please refer to the catalog.

Clean, safe, and easy to handle! Takumina's carbon dioxide pH neutralization device 'NAC'.

  • Water treatment equipment
  • Wastewater/wastewater treatment equipment
  • Other pumps

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
IPROS17259231511647548288.jpeg

[Takumina] Customize with a wealth of options! We have released the latest information on the carbon dioxide pH neutralization device 'NAL'.

Takumina's boiler wastewater carbon dioxide pH neutralization device 'NAL' series. We customize high-precision pH neutralization devices according to your needs. ■ No generation of harmful substances, clean No generation of corrosive gases or harmful substances, ensuring cleanliness. ■ Safe with no concern for secondary pollution Compared to neutralization treatment using sulfuric acid or hydrochloric acid, it is easier to handle, poses less risk, and is a safe device with no concern for secondary pollution. ■ No complicated handling, easy to use No complicated handling is required with the use of carbon dioxide cylinders. The gas is extracted in gaseous form from the cylinder, so no vaporization device is necessary. ■ High mixing efficiency achieved with unique internal control technology The newly adopted Takumina mixer significantly improves the mixing efficiency of carbon dioxide. ■ Easy operation and maintenance Operation is simple, and maintenance is easy. Various safety designs and alarm mechanisms are provided to enhance system reliability. ■ Space-saving and easy installation The main unit requires a compact installation space of 600×600mm and can be used both indoors and outdoors. Additionally, no stirring tank is needed, allowing for processing with just this device. For detailed information such as specifications, please refer to the catalog.

Diamond electrodes contribute to improving water quality in wastewater treatment! Environmental regulations are being strengthened in various countries.

  • Other water treatment equipment
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Contributing to the reduction of environmental impact! Fluorine-based surfactants can also be decomposed using diamond electrodes.

  • Other water treatment equipment
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Contributing to decolorization, COD/BOD reduction, and the decomposition of refractory substances and organic matter through direct electrolysis technology!

  • Other water treatment equipment
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Anytime, anywhere, for anything! Easy and convenient micro-nano bubble generator 'Foamest Column Series'

  • Other cleaning machines
  • Wastewater/wastewater treatment equipment
  • Oil-water separator

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

5 days for measurement? Or a few hours? Explaining the difference between BOD and COD!

  • Water quality testing
  • Wastewater/wastewater treatment equipment
  • Dissolved Oxygen Meter

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

The cause of the trouble is not just one! We provide comprehensive proposals based on field investigations to assist with fundamental improvements.

  • 4a.png
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

When the condition is poor, suspect the "measuring instrument"! Deterioration, dirt, or calibration errors of the sensor—please consult us at least once.

  • 8a.png
  • 8b.png
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

In addition to deodorant compatibility testing and selection testing, installation work for spraying devices is also possible!

  • 13a.png
  • 13b.png
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Abnormalities in drainage treatment may have causes in areas that are not visible. Please feel free to consult us about the inspection and maintenance of aeration tanks.

  • 16a.png
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Comprehensive support from automatic control design and construction to alert settings and equipment maintenance!

  • 19a.png
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Subscription Start: Nanobooster Membership - Extending the Lifespan of Water-Soluble Coolants - Nanobubble Generator

  • 写真2.jpg
  • 写真3.jpg
  • Other environmental equipment
  • valve
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

For those who are struggling with issues such as ineffective drainage treatment! By updating the diffusers in the aeration tank, we have confirmed the restoration of normal aeration and DO levels.

  • 10-2.png
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Filter

classification
Delivery Time
Location