We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Prevention Device.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Prevention Device Product List and Ranking from 107 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Jan 07, 2026~Feb 03, 2026
This ranking is based on the number of page views on our site.

Prevention Device Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Jan 07, 2026~Feb 03, 2026
This ranking is based on the number of page views on our site.

  1. 英田エンジニアリング Okayama//Industrial Machinery
  2. 日本システム企画 東京本社  Tokyo//Other manufacturing
  3. 兼工業 東京営業所 Tokyo//Machine elements and parts
  4. 4 ミナギ Osaka//Industrial Machinery
  5. 5 セイシン企業 Tokyo//Manufacturing and processing contract

Prevention Device Product ranking

Last Updated: Aggregation Period:Jan 07, 2026~Feb 03, 2026
This ranking is based on the number of page views on our site.

  1. Kengyo Industrial Co., Ltd. General Catalog 兼工業 東京営業所
  2. Automobile theft prevention device i/lock 英田エンジニアリング
  3. Electric Vehicle Theft Prevention Device i/lock 英田エンジニアリング
  4. 4 Powder clogging and adhesion prevention device "Jet Blaster" セイシン企業
  5. 5 Powder particle clogging prevention device "Brodisk" ミナギ

Prevention Device Product List

121~150 item / All 323 items

Displayed results

[Information] Hardy Create News No. 190

Measures to prevent falls, drops, and damage! Introducing a heavy machinery proximity warning system utilizing active IC tags.

This document features an introduction to safety products in "Hardy Create News No. 190." It separately introduces the features of the "Pallet Rack Option," which prevents rack tipping during disasters, as well as the lineup of "Pale Guard." It also includes the features of the "IC Rider Z," which prevents collisions between forklifts and operators, making it a useful reference for those considering implementation. 【Contents (partial)】 ■ Introduction to Pallet Rack Options ■ Tipping Prevention Measures! ■ Falling Prevention Measures! ■ Damage Prevention Measures! ■ Pale Guard *For more details, please refer to the related links or feel free to contact us.

  • palette
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Remote Control Forgetting Prevention Device "RemoSafe"

Prevents the loss of remote controls for truck-mounted cranes! Issues a warning when the remote control is detached from the base.

"RemoSafe" is a device designed to prevent the loss troubles caused by forgetting remote controls (RC) for vehicles such as unic vehicles and transport vehicles. If the remote control is not set on the dedicated base, an alarm will activate when the engine is turned on, preventing work interruptions due to loss and supporting smooth progress. Additionally, by applying the included steel seal to non-metal products like remote controls, it can accommodate products other than metal, making it usable with any type of remote control. [Features] ■ Loss prevention alarm function ■ Introduction of metal detection sensor ■ Reduction of on-site burden ■ Reduction of extra costs ■ Improved reliability *For more details, please refer to the related links or feel free to contact us.

  • Company:TCI
  • Price:Other
  • Other safety equipment
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Foreign Substance Contamination Prevention Device 'Good Eye J1 for 1 Camera'

Strong against noise! A punch misalignment prevention device for punching machines, preventing cross-contamination!

The "Good Eye J1 Single Camera" can store up to 999 images and is designed to prevent noise interference and contamination from different types. With the filtering feature, you can recheck NG images on the monitor. Additionally, selected images can be saved to a USB. 【Features】 ■ Resistant to noise ■ Can store up to 999 images ■ Allows rechecking of NG images on the monitor through filtering ■ Selected images can be saved to USB *For more details, please download the PDF or feel free to contact us.

  • Surveillance Cameras
  • Surveillance Camera System
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Crane derailment prevention device "Crane Gripper"

Safety measures for equipment in the factory! Prevents overhead cranes from derailing or falling during earthquakes and other emergencies!

The "Crane Gripper" prevents derailment and falling of overhead cranes, ensuring the safety of workers. It moves along the running rails and maintains a grip on the rails, making it physically impossible to detach. Even after a disaster, it enables the quick resumption of overhead crane use, supporting normal operations. 【Features】 ■ Ideal for preventing derailment and falling of overhead cranes ■ Moves left and right along the running rails ■ Physically impossible to detach due to its claw structure gripping the rails For more details, please refer to the catalog or feel free to contact us.

  • others
  • crane
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study on Labor Environment] Fall Prevention Measures

We propose the fall prevention device "Escort Aileron"! Introducing safety measures for tank construction.

At the food factory, it was pointed out that the outdoor CO2 circulation tank only had a ladder, raising concerns about safety during operations, and they sought advice on countermeasures. We proposed the "Escort I-Rail," a fall prevention device that can be installed in extremely small spaces. As a result, they were pleased that a long-standing issue had been resolved. During actual operations, simply moving the Iris allows for safe work, which was also evaluated as an improvement in work efficiency. 【Case Study】 ■Issues - They want to replace the back basket ladder, but there is no installation space. - There is no place to attach a safety harness during tank top inspections, posing a high risk. ■Proposal - We proposed the fall prevention device "Escort I-Rail." *For more details, please refer to the PDF document or feel free to contact us.

  • tank
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Noise trouble case / Flow meter values fluctuate during inverter pump operation.

Numerous examples! Introducing trouble cases caused by noise. Robots, logistics warehouses, plasma arc welding, servo-based weighing systems, etc...

【Noise Trouble Cases】 ■ The flow meter value fluctuates when the inverter pump is operating. ■ When the painting robot operates, the leakage breaker malfunctions. ■ In the logistics warehouse, the sensor module frequently fails. ■ The system experiences abnormal shutdown during plasma arc welding. ■ In the servo-based weighing system, the analog signal from the weighing controller fluctuates. ■ Frequent errors occur in the district heating and cooling system. ■ An alarm for leakage current is triggered when the overseas compressor operates. We also introduce many cases on our company website "Noise Maybe Blog," so please take a look. (You can view it from the link below.)

  • Transformers
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Noise Trouble Consultation Room <Noise Consultation / Noise Investigation / On-Site Technical Assistance>

The experience and knowledge accumulated since our founding are our strengths! We are like a "refuge" for all kinds of noise troubles.

The Noise Trouble Consultation Room is a consulting department where specialized engineers support the resolution of noise troubles faced by customers. We have a track record of solving even the most challenging issues, which are often described as "miraculous" if resolved. As a sort of "refuge" for all noise-related troubles, we provide consultations via email and phone, conduct on-site investigations, and offer advice on countermeasures to help resolve the problems our customers face. If you are troubled by noise, please feel free to contact us. 【Service Contents】 ■ Noise Consultation ■ Noise Investigation ■ On-site Technical Assistance *For more details, please refer to the PDF document or feel free to contact us.

  • Other services
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Video available that explains in 10 minutes! Pipe rust prevention 'NMR Pipe Protector'

Eliminates the need to replace old pipes! Extends the life of pipes for over 40 years! The effectiveness is proven by data.

The NMR Pipe Protector can be installed on the outside of pipes without cutting them, allowing for measures against red rust inside the pipes. It can transform existing red rust into black rust, rejuvenating the interior of the pipes! This means that you can continue to use the same pipes until the lifespan of the building without having to replace the old pipes. 【Features】 - Installed from the outside without cutting the pipes - Improves and prevents red rust inside the pipes - Allows for the continued use of existing pipes - No need to introduce chemicals or scrape the inside of the pipes, ensuring safety - No power supply required, zero running costs! 【TV Broadcast Video Available!】 We are streaming a video of the content that was aired on television. You can watch an overview of the NMR Pipe Protector in about 10 minutes. Customer testimonials from those who have actually implemented it are also featured. Please take a look. *This video was broadcast on February 28, 2019, on TOKYO MX's business program "Kigyo Tamashii." *Please feel free to contact us first.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Acquisition of a US patent for pipe rust prevention, NMR pipe protector popular in the UK.

Introducing examples of the rust prevention effect of the "NMR Pipe Protector" in pipes in the UK!

The red rust prevention device for piping, "NMR Pipe Protector," has obtained patents and registrations in the United States and major countries around the world after undergoing rigorous patent examinations abroad regarding its practicality and other factors. On February 16, 2004, the first installation in the UK was at Addenbrooke's Hospital, affiliated with the University of Cambridge. The NMR Pipe Protector holds a patent in the UK and established its reliability through presentations at conferences related to "corrosion," leading to its installation upon recommendation from the University of Cambridge. The hot water pipes at Addenbrooke's Hospital experienced leaks due to bacterial corrosion and red rust deterioration just three years after the piping was updated. However, after the installation of the NMR Pipe Protector, red rust in the hot water piping made of galvanized steel was prevented in just 11 days. The iron ion concentration due to red rust in the hot water decreased from 1.07 mg/L before installation to 0.188 mg/L after 11 days, falling below the water quality standard of 0.2 mg/L. The transformation of red rust in the hot water pipes to black rust with a volume reduction to one-tenth confirmed the rust prevention effect of the NMR Pipe Protector. [Case Studies (Partial)] - Addenbrooke's Hospital - St Thomas' Hospital - Harrods Department Store - BBC (British Broadcasting Corporation)

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Extending the life of apartment water supply pipes is achieved by converting red rust to black rust.

The piping internal red rust prevention device "NMR Pipe Protector" reduces red rust in the water supply pipes of apartments to insoluble and passive black rust, extending the lifespan of the building.

In addition to pipe rehabilitation, there is the "NMR method," which uses our internal rust prevention device, the "NMR Pipe Protector," to reduce red rust to insoluble and passive black rust. Vinyl-lined steel pipes are commonly used for condominium water supply (distribution) piping, where the straight sections do not deteriorate from red rust, but only the joints do. By converting this red rust to black rust, pipe replacement becomes unnecessary, reducing costs to 1/5 to 1/10. The NMR Pipe Protector utilizes free electrons in the water to convert internal red rust to black rust. Since the NMR Pipe Protector is installed on the outside of the pipes, it does not come into direct contact with the water inside, making it hygienic and safe. Through on-site surveys conducted by our technical workers, we can implement our product at suitable installation locations, enabling appropriate pipe rehabilitation throughout the entire piping system. The NMR method has obtained a patent as a groundbreaking pipe rehabilitation technique and has been recognized through research papers presented at the "Asia-Pacific Corrosion Society" and the "Japan Society of Corrosion Engineering." It has been highly evaluated for its water quality safety and has been adopted in many renowned hospital facilities around the world. The NMR Pipe Protector comes with a rust prevention effect guarantee, allowing for worry-free implementation. *For more details, please refer to the PDF or contact us.*

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

The apartment water supply pipes are prone to leaks due to deterioration from red rust, and you won't notice until it's too late!

By protecting only the joint sections of the water supply pipes in the apartment with the red rust prevention device "NMR Pipe Protector," pipe replacement is unnecessary.

The water supply pipes in buildings such as condominiums are made of vinyl-lined steel pipes, so the straight sections do not deteriorate, and only the joints experience red rust deterioration. Since there is no change in the color of the water coming from the faucet and no red water is produced, it is difficult to notice the red rust deterioration inside the pipes. Our company will first conduct an on-site inspection using an endoscope to investigate the condition of the red rust deterioration, and based on that, we will propose the introduction of the optimal "NMR Pipe Protector." With this product, it is possible to prevent red rust deterioration throughout the entire piping, including the joints. By introducing this product, it is possible to eliminate the need for costly pipe replacement expenses, which can be a significant financial burden for customers within limited repair budgets, and extend the life of existing pipes for over 40 years, thereby prolonging the lifespan of the pipes until the building's lifespan ends. *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Cosmo Kajigaya Le Seine introduces NMR pipe protectors to prevent piping red rust.

The management association of "Cosmo Kajigaya Le Seine" has verified the prevention of red rust deterioration in water supply pipes using the red rust prevention device "NMR Pipe Protector," ensuring long-term pipe longevity.

In the condominium "Cosmo Kajigaya Le Seine," where the NMR Pipe Protector has been introduced, polyvinyl chloride lined steel pipes (VLP) were used for the water supply piping. Polyvinyl chloride lined steel pipes (VLP) refer to pipes that are internally coated with polyvinyl chloride. While the joints of the pipes are prone to red rust deterioration, the straight sections are excellent in durability and corrosion resistance, and are currently used in most buildings' water supply pipes. However, this water supply piping has high maintenance costs, and after several decades of installation, measures against water leaks due to red rust at the joints become necessary. Many water supply pipes experience issues such as red rust blockage at the joints, water leaks, and deterioration of water quality after twenty years. The NMR Pipe Protector converts red rust into black rust, resolving these issues. Unlike pipe replacement work, the NMR Pipe Protector can be installed without water service interruption, transforming the red rust inside the water supply pipes into black rust that strengthens the pipes. By introducing the NMR Pipe Protector, red rust becomes inert black rust, extending the lifespan of the pipes by over 40 years. *For more details, please refer to the PDF materials or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pipe rust prevention, the Royal Bank of Scotland has introduced the NMR Pipe Protector.

The Royal Bank of Scotland confirmed the rust prevention and lifespan extension effects of NMR pipe protectors for air conditioning piping, reducing piping renewal costs to less than one-tenth.

As an example of the introduction of the "NMR Pipe Protector," we present the case of the Royal Bank of Scotland. Branch 250 had been in operation for 18 years and was facing issues with red rust in the air conditioning hot water piping. Due to the high costs of rust inhibitors and a shift towards environmental considerations, the "NMR Pipe Protector" was installed in the air conditioning hot water piping in March 2018. As a result of the installation, the iron content value from red rust in the hot water, which was 1.10 mg/L before installation, was re-examined 9 weeks after the installation of the NMR Pipe Protector, revealing that the hot water was clear and the amount of dissolved iron in the hot water had decreased to approximately 1/3, or 0.41 mg/L. The progression of red rust within the piping also stopped, and the red rust had transformed from a surface state to black rust. The NMR Pipe Protector successfully resolved the issue of red rust dissolving into the water and halted its progression. There is now no longer a concern about the acceleration of piping deterioration due to red rust. Additionally, the coating from black rust has a reinforcing effect on the piping, and it is expected to extend the lifespan of the piping to match the lifespan of the building. *Customer feedback (customer testimonials) and other PDF materials are currently available for free! *Please feel free to contact us first.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

The NMR Pipe Protector was featured on the business program "Corporate Spirit."

There are over 4,200 installations! The red rust prevention device for pipes, "NMR Pipe Protector."

The piping anti-rust device "NMR Pipe Protector" was introduced on the Tokyo MX business program "Corporate Spirit." This product has the function of transforming red rust into black rust. By reducing the size of water aggregates and utilizing free electrons in the water, it reduces red rust in the piping to black rust. While suppressing the occurrence of new red rust, it reduces existing red rust to black rust, thereby strengthening the piping itself. Black rust forms a dense film on the surface of iron, protecting it from red rust, which corrodes iron. It has been used as a rust preventive since ancient times and is still used today for coatings on iron products such as Nambu iron kettles and Chinese woks. This product leverages the advantages of black rust to extend the lifespan of piping. [NMR Pipe Protector Features] ■ Can fundamentally solve the red rust problem ■ Excellent cost performance ■ Installation work is small-scale (no need for water stoppage) *For more details, please refer to the PDF materials or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pipe rust prevention, the BBC in the UK has introduced the NMR pipe protector.

Preventing red rust in the air conditioning pipes of the BBC in the UK, extending the life of the pipes by preventing leaks with the red rust prevention device 'NMR Pipe Protector'

The air conditioning piping in the main block building of the BBC (British Broadcasting Corporation) is 53 years old and has been experiencing leaks due to red rust deterioration. To avoid disruptions in program production during the pipe replacement work, a red rust prevention device called the "NMR Pipe Protector" was installed. The effectiveness of the NMR Pipe Protector in preventing red rust was verified in just about one month. Before installation, the iron content in the circulating water of the cooling water piping in the main block building was very high at 5.53 mg/L, indicating serious red rust deterioration. However, a water quality test conducted 32 days after the installation of the NMR Pipe Protector showed a significant reduction to 0.05 mg/L, which is less than 1/100 of the previous value, confirming the rust prevention effect due to the black rust formation caused by the NMR Pipe Protector. In the Stage 5 building, the iron content was also very high at 3.80 mg/L before the installation of the NMR Pipe Protector, but after installation, it decreased to approximately 0.06 mg/L, which is about 1/63 of the previous value, completely preventing red rust deterioration in the cooling water piping. Even in the 53-year-old BBC building, the high effectiveness of red rust prevention has been proven to prevent leaks and extend the life of the piping. *For more details, please refer to the PDF document or feel free to contact us.*

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pipe anti-corrosion, hospital water supply and air conditioning piping longevity device "NMR Pipe Protector"

NMR Pipe Protector extends the lifespan of hospital water supply pipes and air conditioning chilled and hot water pipes affected by red rust deterioration for over 40 years at one-tenth the cost of pipe replacement.

Water supply pipes and chilled/hot water piping generally require replacement due to aging deterioration. In hospitals with over 25 years of operation, the chilled/hot water piping can experience red rust deterioration, leading to red rust blockage. At the same time, this red rust can flow into copper fan coils, causing blockages and reducing heating and cooling efficiency. Additionally, the red rust can accumulate within the heat source equipment, shortening its lifespan. In the water supply pipes, red rust can develop at the joints, and as the red rust deterioration progresses within both pipes, the threads at the joints can break off, leading to leaks during strong earthquakes. The NMR Pipe Protector prevents red rust deterioration, transforms red rust into black rust to improve pipe strength, and extends the lifespan of the piping. Since the chilled/hot water system is centralized, if piping replacement is carried out, the hospital must halt operations for more than six months, and the replacement costs can reach hundreds of millions to over a billion yen. The damages caused by operational downtime are also significant, leading to a demand for technology that can extend the lifespan of the air conditioning piping without replacement. The NMR Pipe Protector, a device for preventing red rust within pipes, has made this possible at less than one-tenth the cost.

  • top-block01-image01.jpg
  • top-block02-image01.png
  • top-block02-image02.png
  • Water treatment equipment
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Calcium scale solidification adhesion prevention device "Non-Scaler"

The only one in the world! Prevents calcium scale without using chemicals.

The Non-Scaler is the world's only device that solves calcium scale solidification and adhesion problems without using chemicals. The Non-Scaler oxidizes dissolved calcium in water as hydroxide through blades inside the device, transforming it into calcium carbonate microparticles (nanoparticles) that are dispersed and flow in the water. Once transformed into calcium carbonate nanoparticles, they do not change even when heat is applied, preventing issues such as damage to pump blades and clogging in heat exchangers caused by calcium scale. ■Features - Excellent calcium adhesion prevention effect - Prevents calcium adhesion when installed in the make-up water pipe of cooling towers - Prevents damage to pump blades - Prevents clogging in heat exchangers - Prevents calcium adhesion in piping - No chemicals required - No external power supply needed - Compatible with pipe sizes from 15A to 250A *You can download materials explaining cost reduction methods. *Please feel free to request a free estimate via the inquiry form.

  • results_01.jpg
  • 製品画像2.jpg
  • 製品画像3.jpg
  • ns_place01.gif
  • ns_place02.gif
  • ns_place03.gif
  • shikumi.jpg
  • onsen.jpg
  • Heating device
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[NMR Pipe Protector Verification Results] Office Building #TK

Prevent the progression of red rust and demonstrate the rehabilitation of piping due to black rust! A case where the amount of black rust increased to 16.9%.

At that time, the facility had been in operation for 42 years, and there were significant concerns about the corrosion of the hot water supply piping, which led to the adoption of the "NMR Pipe Protector." Before the installation of this product, the amount of black rust in the piping was 0.9%, but after 6 months of actual operation following installation, it increased to 16.9%, a relative increase of 1877.7%. The reduction of red rust to magnetite (black rust) has been demonstrated. In the future, if all the red rust turns into black rust, the piping will not require replacement as long as external corrosion does not occur. 【Introduction Overview】 ■ Location: Shibuya, Tokyo ■ Building Overview: 42 years old, 9-story office building ■ Installation Date: January 27, 2016 ■ Installed Piping: Cooling water pump primary side hot water supply piping (SGP pipe 200mm) ■ Number of Installations: PT-200DS × 1 unit *For more details, please refer to the PDF document or feel free to contact us.

  • Piping Materials
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[NMR Pipe Protector Verification Results] Major DPE Factory

Piping with a statutory useful life of 15 years has been extended by 40 years! Maintaining the condition of the piping without red rust deterioration until 55 years of age.

In this property, galvanized steel pipes (SGP) are used for the water supply piping, and at 35 years old, the pipes were diagnosed to have a lifespan of only 2 months due to frequent leaks and the occurrence of red water. To prevent red rust and extend the life of the pipes, an "NMR Pipe Protector" was installed. In the water quality test before installation, the iron content was 0.5 mg/l, and there was a significant occurrence of red water. However, six days after installation, the iron content dropped to below 0.05 mg/l, and the red water was completely resolved. Subsequently, water quality tests conducted 14 years and 20 years after installation showed that red rust had completely disappeared, and new leaks were entirely prevented, proving the rehabilitation of the piping. [Effects After Installation] ■ Water quality test six days after installation showed iron content below 0.05 mg/l, and red water was completely resolved. ■ Water quality tests 14 years and 20 years after installation showed that red rust had completely disappeared. ■ New leaks were entirely prevented, proving the rehabilitation of the piping. ■ Pipes with a statutory useful life of 15 years were extended by 40 years, maintaining a condition free from red rust deterioration until 55 years old. *For more details, please refer to the PDF materials or feel free to contact us.

  • Piping Materials
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[NMR Pipe Protector Verification Results] Kumamoto Red Cross Hospital

The total iron concentration in the water is also less than 0.1 mg/L, maintaining a good condition where red rust does not dissolve in the water!

At Kumamoto Red Cross Hospital, a red rust prevention device called "NMR Pipe Protector" was installed in the air conditioning chilled and hot water piping to prevent red rust after 16 years of construction, and the rust prevention effect was verified. Two weeks after installation, water samples were taken from the air conditioning chilled and hot water piping, and upon retesting, the total iron content due to red rust in the water had significantly decreased to 0.07 mg/l. On February 27, 2019, four years after installation, water sampling was conducted, and it was confirmed that new red rust was completely prevented, and the existing red rust had been converted into insoluble black rust in the water, maintaining the water's transparency. [Summary] ■ Before installation: The total iron content due to red rust in the water was 12.3 mg/l, indicating progression of red rust in the piping. ■ Effects after installation: - Two weeks after installation, the total iron content due to red rust in the water significantly decreased to 0.07 mg/l. - Four years after installation, new red rust was completely prevented. - The existing red rust was converted into insoluble black rust in the water, maintaining the water's transparency. - The total iron content in the water was also maintained at less than 0.1 mg/L, indicating that red rust was not dissolving in the water. *For more details, please refer to the PDF document or feel free to contact us.

  • hos-kn_sy.jpg
  • hos-kn_g.jpg
  • hos-kn_sm.jpg
  • hos-kn_s4.jpg
  • hos-kn_bunseki11.jpg
  • hos-kn_bunseki22.jpg
  • Piping Materials
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[NMR Pipe Protector Verification Results] Hospital #E

The amount of red rust in the air conditioning hot water piping has significantly decreased! Completely preventing the progression of red rust and proving the rust prevention effect.

At Hospital E, which was built 30 years ago, there were concerns about leaks due to the progression of red rust deterioration in the air conditioning hot water piping that uses galvanized steel pipes (SGP). Therefore, a red rust prevention device called "NMR Pipe Protector" was installed. Before installation, a sample of the circulating air conditioning hot water was taken, revealing that the total iron content in the water due to red rust was 360 mg/l, indicating significant corrosion within the piping. Two weeks after the installation of the product, a sample of the air conditioning hot water showed that the total iron content in the water had significantly decreased to 0.4 mg/l. [Introduction Overview] ■ Hospital Location: Ebetsu City, Hokkaido ■ Hospital Overview: 30 years old, 4 stories, 200 beds (entire building) ■ Installation Date: November 2017 ■ Installed Piping/Number of Installations - Main building heat exchanger secondary side hot water supply pipe (SGP pipe 100mm)/PT-100DS×1 unit - <Water Supply System> PT-100DS×2 units *For more details, please refer to the PDF document or feel free to contact us.

  • result_he_sy.jpg
  • result_he_g.jpg
  • result_he_sm.jpg
  • result_he_s2s.jpg
  • result_he_s4s.jpg
  • Piping Materials
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[NMR Pipe Protector Verification Results] Water Supply Pipe in Binh Phuc Province, Vietnam

The red rust inside the cast iron water supply pipe has turned into black rust! It has been proven that the leaching of red rust into the water has been completely prevented.

In the Huong Canh area of the Water Supply Bureau in Binh Phuc Province, Vietnam, cast iron pipes (150A) have been in use for 15 years, leading to the progression of red rust corrosion inside the pipes, which resulted in the regular occurrence of red water. To address this red water issue, a red rust prevention device called the "NMR Pipe Protector" was installed at the base of the cast iron water supply pipes (150A). Before installation, the water color and the amount of red rust at the sampling points located 500m north, 300m west, and 600m south of the installation site were as follows: the northern point had a light brown color with 7.0 mg/l of red rust, the western point had a brown color with 8.0 mg/l, and the southern point had a dark brown color with 23 mg/l. Two weeks after installation, the northern point showed a lighter color and a reduction in red rust to 4.6 mg/l. The western point nearly lost its color, decreasing to 2.0 mg/l. The southern point changed to a light brown color with a reduction to 12 mg/l. *For more details, please refer to the PDF document or feel free to contact us.*

  • screenshot_01.png
  • Piping Materials
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[NMR Pipe Protector Verification Results] Izu Ohni Country Club

The progress of red rust completely stopped just one month after installation! A case where the discoloration of the filter also decreased!

This property has been in existence for 33 years, and due to significant red rust blockage at the joints of the water supply pipes made of different metals, we adopted the pipe rehabilitation device "NMR Pipe Protector." Before the installation of the NMR Pipe Protector, a white filter was attached to the kitchen sink water supply faucet for seven days, during which the filter became discolored brown due to red rust generated in the water supply pipes. After dissolving the captured iron content with purified water and measuring the iron concentration, it was found that the iron level in the water was 21 mg/l, indicating that the red rust corrosion in the pipes was quite advanced. One month after installation, a white filter was attached under the same conditions as before, and it was confirmed that the filter's discoloration had reduced to light brown, with the iron concentration decreasing significantly to 5.8 mg/l. Additionally, six months after installation, a white filter was again attached under the same conditions, and it was confirmed that the filter's discoloration had nearly returned to white, with the iron concentration further decreasing significantly to 0.75 mg/l. From this, it can be concluded that just one month after the installation of the NMR Pipe Protector, the progression of red rust was completely halted, and at the same time, the surface of the red rust in the water supply pipes transformed into a non-soluble black rust, resulting in a reduction of iron leaching into the water and a decrease in filter discoloration.

  • oth-i_02.jpg
  • oth-i_g.jpg
  • 伊豆大仁カントリークラブ.jpg
  • Piping Materials
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[NMR Pipe Protector Verification Results] Nursing Facility #HO

The red rust inside the water supply pipe has transformed into hard crystalline black rust with a volume reduction of 1/10! The rehabilitation of the piping due to the black rust formation from red rust has been confirmed!

This nursing facility had experienced significant deterioration due to red rust in the water supply and hot water supply pipes. Therefore, when the building was 25 years old, a red rust prevention device called the "NMR Pipe Protector" was installed in the water supply pipe on the secondary side of the rooftop water tank and in the hot water supply pipe on the secondary side of the boiler. Before the installation of the NMR Pipe Protector, the iron ion concentration in the water supply was 2.27 mg/l, and the color degree was 20, indicating severe deterioration due to red rust in the pipes. Four weeks after the installation of the NMR Pipe Protector, the iron ion concentration in the water dropped to 0.46 mg/l, and the color degree improved to 5, showing a significant improvement in water quality. Furthermore, the water quality test results 12 weeks after installation showed that the iron ion concentration was 0.03 mg/l, and the color degree was less than 0.5. The red rust in the water supply pipe had transformed into hard crystalline black rust with a volume reduction of 1/10, stopping the leaching of red rust into the water. The rehabilitation of the pipes due to the black rust formation was confirmed. This demonstrated that if the use of the NMR Pipe Protector continues, both the water supply and hot water supply pipes can be extended to the lifespan of the building.

  • hos-ho_02.jpg
  • Piping Materials
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Non-Scaler Introduction Case Study] Major Chemical Plant

Prevention of calcium scale adhesion and cooling efficiency in heat exchangers! A case study that reduced the frequency of line stoppages due to pump disassembly and cleaning once every 1.2 months.

The heat exchanger at the chemical plant was subject to calcium scale buildup, necessitating disassembly, cleaning, and washing every five months. When scale accumulated on the heat exchanger, it reduced cooling efficiency and negatively impacted product quality. After installing a "non-scaler" following the cleaning of the heat exchanger, there was no calcium carbonate buildup on the hot water piping even after five months, resulting in maximum cooling effectiveness of the cooling water and maintaining the lowest defect rate for products. Additionally, the need to stop the plant every five months to scrape off calcium carbonate from the outside of the hot water piping was eliminated, leading to a reduction in product defect rates and an improvement in productivity. *For more details, please refer to the PDF document or feel free to contact us.*

  • nsresults_02_before.jpg
  • nsresults_02_after.jpg
  • Piping Materials
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[NMR Pipe Protector Verification Results] Moseley Hospital (NHS)

Prevent red rust and leaks in the hot water piping of Moseley Hospital!

Moseley Hospital has two independent hot water systems: one connected to the storage tank and the other connected to the hot water header, with galvanized steel pipes used in the hot water piping. As a result, NMR pipe protectors were installed in the storage tank piping and the hot water header piping to prevent red rust corrosion and leaks in both hot water systems. Water samples were taken from the hot water piping at five locations, and the average iron content in the water was calculated. Before the installation of the NMR pipe protectors, the average value was 13.824 mg/l. After 15 weeks of installation, it decreased to 1.3882 mg/l; after 31 weeks, it further decreased to 0.4762 mg/l; and after 49 weeks, it reached 0.3428 mg/l, showing a significant reduction. This result demonstrated that the NMR pipe protectors prevented the formation of new red rust within the pipes and reduced existing red rust to black rust, which is insoluble in water and has a volume that is one-tenth of that of red rust. It has been proven that by continuing to install NMR pipe protectors, the hot water piping will transform 100% of the red rust within the pipes into black rust, thereby extending the lifespan of the building.

  • hos-mo_g.gif
  • hos-mo_e01.jpg
  • hos-mo_e02.jpg
  • Piping Materials
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Effect of the calcium scale solidification adhesion prevention device "Non-Scaler"

The calcium scale prevention device "Non-Scaler" solves the calcium scaling problem in hot water boilers without using ion exchange resins or strong alkaline agents.

Calcium scale inevitably adheres to the interior of hot water boilers and similar equipment. To reduce the adhesion of calcium scale, traditionally, ion exchange resins have been used to soften the water by removing calcium ions before producing hot water in the boiler. The residual calcium in the water crystallizes as insoluble calcium carbonate within the boiler and adheres to it. Traditionally, strong alkaline agents were added to the boiler to prevent the formation reaction of calcium carbonate. However, strong alkaline hot water is highly corrosive to metals, leading to corrosion and deterioration of the boiler itself, internal piping, and hot water piping, which shortens the lifespan of the boiler and connected piping systems to around 10 years. The calcium scale prevention device "Non-Scaler" reacts the calcium in the water with free carbon dioxide within the Non-Scaler, forcibly transforming it into fine particles of calcium carbonate that are dispersed and flow in the water. Once calcium carbonate is converted into fine particles, it remains unchanged even under the high temperature and pressure conditions inside the boiler, flowing in its particulate state. Additionally, the effects of corrosion and deterioration caused by strong alkaline agents are eliminated, making it possible to extend the lifespan of the boiler and hot water piping by more than double.

  • Piping Materials
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Non-Scaler Implementation Case: Major Food Factory

A case of preventing flow reduction due to calcium buildup in the secondary side valve of the warm water piping.

**Effects After Installing the Non-Scaler** - Eliminated the decrease in flow rate caused by calcium crystals - Both flow rate and temperature remain stable even after 4 months - No need for disassembly cleaning, significantly reducing maintenance time and burden At our factory, we used groundwater containing a high level of calcium (180 mg/L), which made it easy for calcium scale to adhere inside the valves, frequently causing a decrease in flow rate. As a countermeasure, we introduced a coil electromagnet device two years ago, but there was hardly any observed effect in preventing scale. Therefore, we newly installed a "Non-Scaler," and clear improvement effects were confirmed. Before installation, due to the decrease in flow rate and the accompanying drop in temperature, we had to perform disassembly cleaning of the valve plates approximately every 4 months, which took about 36 hours each time. However, after the introduction of the Non-Scaler, even after 4 months, there were no issues with the decrease in flow rate or temperature, and disassembly cleaning of the valves became unnecessary. Current maintenance now only involves lightly tapping the outside with a rubber hammer to remove softened deposits, leading to a significant reduction in work time. *For more details, please refer to the PDF document or feel free to contact us.*

  • NSカルシウム固着物2.jpg
  • IPROS00071495968617236508.png
  • Heating device
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Non-Scaler Introduction Case] Major Chemical Plant B

A case of preventing calcium deposition in the piping of a cooling water line at a chemical plant.

**Effects After Installing the Non-Scaler** - Acid cleaning twice a year is no longer necessary, maintaining productivity without line stoppages. - Significant reduction in cleaning and maintenance costs as well as labor expenses. - Contributes to the longevity of piping equipment. In our factory, we use groundwater as cooling water, which has caused calcium carbonate scale (hard crystals) to adhere to the piping on the secondary side of the pump, necessitating acid cleaning twice a year. During this acid cleaning process, the factory line had to be temporarily halted, leading to significant economic losses due to production stoppages. To address this issue, a "Non-Scaler" was installed on the secondary side of the pump piping. Before installation, as seen in the photos, thick white scale was heavily adhered inside the piping, making removal extremely difficult. However, six months after the installation of the Non-Scaler, there was almost no scale adhesion observed inside the piping, and the effects were clearly evident, allowing for substantial cost reductions. *For more details, please refer to the PDF document or feel free to contact us.*

  • NS_chemicalB_be.jpg
  • NS_chemicalB_af.jpg
  • Heating device
  • Prevention Device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration