We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Switch.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Switch Product List and Ranking from 478 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Oct 22, 2025~Nov 18, 2025
This ranking is based on the number of page views on our site.

Switch Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Oct 22, 2025~Nov 18, 2025
This ranking is based on the number of page views on our site.

  1. 三和電機製作所 Tokyo//Industrial Electrical Equipment
  2. クラウスアンドナイマー 東京本社、大阪営業所 Tokyo//Industrial Electrical Equipment
  3. 大阪自動電機 (オジデン) Osaka//Industrial Electrical Equipment
  4. 4 Suntex Co., Ltd. Shizuoka//Industrial Electrical Equipment
  5. 5 木村製作所 Osaka//others

Switch Product ranking

Last Updated: Aggregation Period:Oct 22, 2025~Nov 18, 2025
This ranking is based on the number of page views on our site.

  1. Factory mat switch: Prevent access to hazardous areas in the factory! エスケイ電子工業
  2. Liquid Level Control Switch "Level Regulator" LC12 新明和工業
  3. Enercon Corporation Dine Pen (Dine Value Test) Catalog ザ・ブルーボアハウス
  4. Dual-hand operation push button switch "Touch Start" 小森安全機研究所
  5. 4 Remote operation of PCs without internet connection is possible with 'IP-KVM'. 因幡電機産業 産機カンパニー

Switch Product List

1741~1755 item / All 3684 items

Displayed results

Emergency stop switch for the belt conveyor 'Emergency Pull Cord Switch'

This is a safety switch designed to reliably stop operations on-site to prevent accidents, such as those involving belt conveyors.

The emergency pull cord switch is a switch used to stop a conveyor belt or similar equipment in the event of an accident. The emergency pull cord switch, installed on the side of the conveyor, allows the pull cord to be mounted along the conveyor, enabling the emergency stop switch to be activated at any position. This emergency pull cord switch is required to be installed on belt conveyors by labor safety and health regulations. 【Features】 ● It is a large switch with high pull cord tension and durability. ● It can be operated from both directions. ● It has two built-in contacts for stopping and alarm purposes. ● A status indicator panel can also be produced. ● Explosion-proof types for factory pressure resistance and dust explosion are also available. *For more details, please download the catalog or contact us.

  • Other safety equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Heavy-duty limit switch "MGL5000 Series"

Improved environmental resistance! Increased mechanical strength! Highly reliable limit switch.

The MGL5000 series is highly resistant to environmental factors and offers a wide variety of options. As a limit switch that requires high reliability, it is a genuine industrial limit switch designed to enhance environmental resistance and possess high mechanical strength. **Features** - **High Mechanical Strength** The housing is made of aluminum alloy die-cast, providing a lightweight yet robust structure with sufficient strength for mounting flanges and other components. The actuator part has a large total travel (T.T), allowing the switch's high mechanical strength to be fully utilized during operation. - **Excellent Environmental Resistance** "Protection Structure" The oil seal on the shaft and the O-ring seal on the cover create a waterproof, oil-resistant, and dust-proof structure suitable for outdoor use. "Vibration and Shock Resistance" With an excellent internal operating mechanism and the synergistic effect of stable contact pressure from the internal switch's snap action, it possesses high vibration and shock resistance. - **Long Lifespan and High Reliability** The front shaft bearing uses roller bearings, and the rear shaft bearing is fixed to the housing, ensuring mechanical longevity.

  • Other safety equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Rope-Pull Emergency Stop Switch 'Pull Stop'

It covers a wide area with one unit and is suitable for replacing numerous emergency stop buttons!

The rope-type emergency stop switch "Pull Stop" is a switch that stops long-distance transport lines such as conveyors by pulling a wire rope. It will stop even if the wire rope becomes loose or breaks. Additionally, since the main unit is equipped with an emergency stop push button switch as standard, it is easy to stop the machinery without pulling the wire rope. This Pull Stop complies with European international standards and JIS safety standards. 【Features】 ○ High reliability compliant with European international standards - Complies with safety standards EN 418, ISO 13850, and JIS B9703 ○ Usable in harsh environments - With a protective structure of IP67, it can be installed around machines that require washing or in dusty environments - Capable of detecting in both left and right directions, reducing the number of installations needed ○ Addresses various safety needs - The operation lever locks when the wire rope is pulled, allowing the operator to confirm safety before restoring the line ○ Stops the transport line by pulling the wire rope ○ Covers a wide area with a single unit

  • switch

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Customized Level Meter for Measuring Suspended Solids in Liquid

Introducing examples of customized sounding level meters tailored to customer specifications.

We are customizing our measurements to meet the request of measuring only the sediment in the tank liquid. 1. Adjusting the detection torque to prevent malfunction due to resistance at the water surface. 2. Using a special rope to prevent corrosion from the liquid. 3. Using specially shaped weights to reduce buoyancy and resistance when descending in the liquid. For more details, please contact us. Matsushima Mejatech responds to customer requests with customizations made possible by in-house production.

  • Level gauges and level switches
  • Flow Control
  • Weighing Control

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Improvement Proposal] Admittance Type Level Switch Performance Test

Even with a large amount attached, it won't malfunction! Introducing a demonstration test with slime!!

Have you ever experienced malfunctions due to adhesion when detecting levels of highly viscous liquids or moist powders? Matsushima Mejatech's admittance-type level switch 'MAL-110' can avoid troubles caused by adhesion and provide stable level detection. This time, we conducted a demonstration test using a highly conductive slime as the measured substance. Thanks to the guard electrode (with a special structure) canceling the effects of adhesion, there were no malfunctions despite a large amount of adhesive material on the probe. [Test] ■ Demonstration test using slime ■ Test product ・ Admittance-type level switch 'MAL-110' ■ Result ・ No malfunctions *For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Admittance Level Switch for Animal Fat Tank Level

Detecting bubbles to prevent leaks! Detecting even low dielectric constant bubbles!! Introducing case studies of animal fat tanks.

We would like to introduce a case study of the admittance-type level switch 'MAL-110' handled by Matsushima Majatech. Conventional capacitive level switches could only detect oils and fats, leading to overflow when a large amount of foam was generated. By adopting our product, we were able to detect low dielectric constant foam, eliminating the overflow issue. 【Case Study】 ■Challenges - Conventional capacitive level switches could only detect oils and fats, causing overflow when a large amount of foam was generated. ■Product Introduced - Admittance-type level switch 'MAL-110' ■Effects - Successfully detected low dielectric constant foam, eliminating overflow. *For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches
  • Liquid level control/level switch
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] River Upstream Water Level Measurement - Radio Wave Water Level Gauge

For monitoring river flooding! A water level gauge that detects flooding by capturing sudden changes in river water levels.

We introduce a case study of the radio wave water level gauge handled by Matsushima Majatech, which has been implemented in upstream rivers. This product detects sudden changes in river water levels and alerts to potential flooding. It can respond to extreme water level changes of about 5 meters in approximately 2 seconds. Microwaves have the property of penetrating steam, allowing for stable detection of the water surface even during fog, storms, or heavy rain. Since it measures the water surface non-contact, it can operate without collision or damage even when sediment or driftwood flows by. 【Case Study】 ■ Implementation Location  ・River ■ Implemented Product  ・Radio Wave Water Level Gauge

  • Level gauges and level switches
  • Other measurement, recording and measuring instruments
  • Distance measuring device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] High-Temperature Equipment Radar Microwave Level Gauge for Sintering Coolers

Proven in the high-temperature environment of steel mills! Monitoring layer thickness for process control! For controlling input amounts and detecting blockages!

We would like to introduce a case study of the "Radar Microwave Level Meter" handled by Matsushima Majatech, which has been implemented in sintering equipment (sintering cooler). This product monitors the thickness of the sintered ore layer for process control and checks the levels after feeding and discharging. It avoids heat sources with an L-shaped waveguide antenna and cools the antenna with purging. A heat shield prevents dust from entering the antenna, stabilizing measurement performance. Please use it for controlling input amounts and detecting blockages. 【Case Study】 ■ Installation Site - Sintering Equipment (Sintering Cooler) ■ Installed Product - "Radar Microwave Level Meter"

  • Level gauges and level switches
  • Other measurement, recording and measuring instruments
  • Distance measuring device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Radar-type Microwave Level Gauge for Corrosion Prevention Liquid Level Measurement

An optional PTFE antenna cap protects the antenna from corrosive gases!

We would like to introduce a case where the "Radar Microwave Level Meter" handled by Matsushima Majortech was implemented in a chemical tank. The gas contact part of this product is made of "SUS304." However, if there is still a possibility of corrosion, attaching the optional "PTFE Antenna Cap" to the antenna will prevent corrosive gases from entering and protect the antenna from corrosion. 【Case Study】 ■ Installation Location - Chemical Tank ■ Installed Product - "Radar Microwave Level Meter" + "PTFE Antenna Cap" * Limited to specific models * For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches
  • Liquid level control/level switch
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Radar-type Microwave Level Gauge for Liquid Level (Foam Countermeasure) Measurement

Even when a large amount of foam is generated during liquid level measurement in the tank, measurement is possible! Stable measurement is achieved using a guide pipe.

We would like to introduce a case study of the radar-type microwave level gauge handled by Matsushima Majatech. There was a problem of false detection due to the influence of bubbles when detecting the liquid level in the container. To address this, we installed a "guide pipe" and introduced our product. Even when bubbles occur at the liquid surface, they do not enter the pipe, allowing for measurement of only the liquid level. 【Case Study】 ■Challenge - False detection occurs due to the influence of bubbles when detecting the liquid level in the container. ■Product Introduced - Radar-type microwave level gauge 'MWLM-PR26H2F' + "Guide Pipe" ■Effect - Even when bubbles occur at the liquid surface, they do not enter the pipe, allowing for measurement of only the liquid level. *For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches
  • Other measurement, recording and measuring instruments
  • Liquid level control/level switch

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration