We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

column Product List and Ranking from 29 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Jul 16, 2025~Aug 12, 2025
This ranking is based on the number of page views on our site.

column Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Jul 16, 2025~Aug 12, 2025
This ranking is based on the number of page views on our site.

  1. null/null
  2. null/null
  3. アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  4. 4 null/null
  5. 5 null/null

column Product ranking

Last Updated: Aggregation Period:Jul 16, 2025~Aug 12, 2025
This ranking is based on the number of page views on our site.

  1. Innovative solid-phase extraction column Oasis PRiME HLB
  2. High Purity Silica Gel HPLC Column "Mightysil Series"
  3. ACQUITY UPLC column
  4. 4 Screening/Purification Prepackaged Column SkillPak Series
  5. 5 SEC column "TSKgel UP-SW3000"

column Product List

46~60 item / All 443 items

Displayed results

Low bleed GC/MS column "VF-5ms"

Guaranteed performance for each item with full inspection of the column! Usable even for highly polar compounds.

The "VF-5ms" is a 5% phenyl column that has undergone advanced inert treatment, designed to maximize sensitivity, accuracy, and the operational efficiency of GC with low bleed GC/MS capabilities. Column bleed is guaranteed to be below 1 pA at 325°C (for 0.25mm × 30m, 0.25μm). It has a slightly higher polarity than VF-1ms and offers excellent selectivity for aromatic compounds. Additionally, due to the advanced inert treatment, it can also be used for highly polar compounds such as phenols. 【Features】 ■ Excellent selectivity for aromatic compounds ■ Improved sensitivity with ultra-low bleed ■ Individual performance guaranteed through complete inspection of all columns *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "DB-XLB"

Expand the temperature limit to 340/360℃! It is possible to create a Duraguard column.

Introducing the 'DB-XLB' handled by Agilent Technologies, Inc. It is possible to create a Duraguard column (guard column integrated column). It is suitable for confirmation analysis, pesticide and herbicide analysis, PCB and PAH analysis, and GC/MS. We offer a wide variety of "GC and GC/MS columns." Please feel free to consult us when needed. 【Features】 ■ Low polarity ■ Temperature limit extended to 340/360℃ ■ Unique selectivity ■ Excellent inertness towards active compounds ■ Suitable for confirmation analysis *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "VF-Xms"

High-purity arylene compounds provide highly accurate analytical results! Ideal for both simultaneous testing and confirmation testing.

The "VF-Xms" is a stable low bleed GC/MS column that shows low bleed among all FactorFour columns. It offers top-class sensitivity and S/N ratio, demonstrating higher polarity than the VF-5ms. Additionally, compared to non-polar MS grade columns, this product is ideal for applications that require high separation efficiency in a short time, such as simultaneous analysis of pesticides. 【Features】 ■ High-purity arylene compounds for high-precision analytical results ■ Usable up to 340°C under isothermal conditions, accommodating a wide range of analyses ■ Ideal column for both simultaneous testing and confirmation testing *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-UI 8270D Ultra Inert"

Excellent peak shape at low concentration! Individually tested at low temperatures using highly verifiable semi-volatile compounds.

We would like to introduce the GC column "DB-UI 8270D Ultra Inert" that we handle. When used for the analysis of semi-volatile organic compounds targeted by EPA Method 8270D, it provides excellent peak shapes, thereby enhancing the reliability of trace analysis in the environmental field. Thanks to Agilent's advanced manufacturing processes, optimized chemistry, and design advancements, both inertness and column-to-column reproducibility are improved, and there is no reduction in bleed or selectivity of the stationary phase. 【Features】 - Industry-leading Ultra Inert treatment and manufacturing - Highly reliable results through excellent testing protocols - "MS Grade" low bleed stationary phase minimizes interference from the column even at high temperatures *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC Column "DB-BAC1/DB-BAC2 Ultra Inert"

Polar target compounds can also be accurately identified! An excellent solution for precise blood alcohol quantification.

The "DB-BAC1/DB-BAC2 Ultra Inert" is a column from the Agilent J&W Ultra Inert GC column family. It is capable of separating t-butanol and n-propanol from commonly encountered interferences in blood matrices. Using this column set in GC/FID/FID analysis achieves excellent selectivity due to the unique polarity of the columns. 【Features】 ■ An excellent solution for accurate blood alcohol quantification ■ Optimized separation capability and baseline separation for challenging peaks in blood alcohol ■ Provides excellent peak shape for low concentration compounds, enabling accurate integration ■ Can accurately identify polar target compounds that are difficult to analyze at trace concentrations *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "VF-35ms"

35% phenyl, 65% dimethyl polysiloxane equivalent for long life! Achieves ultra-low bleed and high stability!

The "VF-35ms" is a medium-polarity GC column suitable for confirmation tests in environmental and chemical analysis. It is manufactured using FactorFour technology, achieving ultra-low bleed and high stability even at 360°C. Additionally, it has a high maximum operating temperature, making it applicable to various analyses. 【Features】 ■ Suitable as a confirmation test column to enhance the reliability of analyses ■ High maximum operating temperature, applicable to various analyses ■ Equivalent to 35% phenyl and 65% dimethylpolysiloxane, with a long lifespan ■ Manufactured using FactorFour technology *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "DB-17ms"

Introducing a medium-polarity column that is almost equivalent to methyl polysiloxane and can be cleaned with solvents!

The "DB-17ms" is a medium-polarity column specifically designed for pesticide analysis with ultra-low bleed. It enhances the reliability of mass spectra. It is inert to active substances, with a maximum temperature of 320/340°C. It features a chemical bond and cross-linking type, making it suitable for CLP pesticides. 【Features】 ■ Nearly equivalent to (50%-phenyl)-methylpolysiloxane ■ Maximum temperature 320/340°C ■ Ultra-low bleed, medium-polarity column, suitable for GC/MS ■ Inert to active substances ■ Enhances the reliability of mass spectra *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "VF-17ms"

Provides excellent reproducibility and long column life! Mainly used in environmental analysis and clinical analysis!

The "VF-17ms" is a medium-polarity GC column that uses 50% phenyl and 50% dimethyl polysiloxane as the liquid phase. Like other FactorFour columns, it achieves ultra-low bleed and improves sensitivity and accuracy. Additionally, the use of advanced deactivation technology enhances the stability of the column, providing excellent reproducibility and a long column lifespan. 【Features】 ■ Uses 50% phenyl and 50% dimethyl polysiloxane as the liquid phase ■ Provides high-quality data through advanced deactivation treatment ■ Offers the highest level of reliability for EPA and USP method validation columns ■ Allows for solvent cleaning, reducing the cost of column replacement *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low-Bleed GC/MS Column "VF-WAXms"

GC columns for high-polarity compounds that achieve long lifespan, improved detection sensitivity, and high precision of data!

"VF-WAXms" demonstrates top-class performance for trace analysis of food, fragrances, and more. It achieves ultra-low bleed, long column lifespan, improved detection sensitivity, and high precision data. Additionally, it minimizes noise and is suitable for trace analysis of highly polar compounds. 【Features】 ■ Top-class performance for trace analysis of food, fragrances, etc. ■ Ultra-low bleed wax column even when using MS ■ Usable temperature range from 20°C to 260°C ■ Minimizes noise and is ideal for trace analysis of highly polar compounds *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-1"

Introducing the column series equivalent to USP PHASE G2 with chemical bonding and cross-linking type!

We would like to introduce our GC column 'DB-1' that we handle. It is a standard non-polar column series made of 100% dimethylpolysiloxane, and it is solvent-washable. Additionally, it boasts a high upper temperature limit and is compatible with DuraGuard. 【Features】 ■ 100% dimethylpolysiloxane ■ Non-polar ■ Excellent general-purpose column ■ Wide range of applications ■ Low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "HP-1"

Excellent performance for low molecular weight alcohols! Outstanding general-purpose column made of 100% dimethylpolysiloxane!

We would like to introduce our GC column "HP-1." It has a wide range of applications and is solvent-washable. We offer a variety of column sizes. Our company provides many columns among manufacturers worldwide. Please feel free to contact us when you need assistance. 【Features】 ■ 100% Dimethylpolysiloxane ■ Non-polar ■ Excellent general-purpose column - "Industrial Standard" ■ Wide range of applications ■ Excellent performance for low molecular weight alcohols (<C5) *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "CP-Sil 5 CB"

We offer two types: fused silica and metal columns! GC columns with a wide usable temperature range!

The "CP-Sil 5 CB" is a column that contains 100% dimethylpolysiloxane as the liquid phase. Separation is based on the boiling points of the compounds and can be applied over a wide temperature range. This chemically bonded product has high inertness, can withstand large injections, and can be used with good reproducibility. 【Features】 ■ Contains 100% dimethylpolysiloxane as the liquid phase ■ Separation is based on the boiling points of the compounds ■ Helps reduce costs ■ Applicable to various analyses ■ Available in two types: fused silica and metal columns *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "Ultra 2"

While equivalent to "HP-5," the specifications for the retention index and capacity factor are more stringent!

"Ultra 2" is a non-polar column made of (5%-phenyl)-methylpolysiloxane. It is a precision-designed product that can be cleaned with solvents and features chemical bonding and cross-linking types, with an operating temperature range of -60 to 325℃/350℃. It has also been tested based on the industry's very strict QC standards. 【Features】 ■ (5%-phenyl)-methylpolysiloxane ■ Non-polar ■ While equivalent to "HP-5," the specifications for retention index and capacity factor are more stringent ■ Chemical bonding, cross-linking type ■ Can be cleaned with solvents *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-17"

Ideal for confirmation analysis of pesticides! Medium-polarity column of phenylmethylpolysiloxane.

We would like to introduce the GC column "DB-17" that we handle. It is a medium-polarity column made of (50%-phenyl)methylpolysiloxane. It is suitable for confirmatory analysis of pesticides. It allows for solvent cleaning and is equivalent to SP Phase G3. 【Features】 ■ (50%-phenyl)methylpolysiloxane ■ Slightly higher polarity than medium polarity (HP-50+) ■ Suitable for confirmatory analysis ■ Chemical bonding and cross-linking type ■ Solvent cleaning possible ■ Equivalent to USP Phase G3 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "HP-17"

Reliable qualitative/quantitative results can be obtained! No need for crosslinked polymers or chemically bonded polymers.

We would like to introduce our product, the 'HP-17'. It is a 50% phenyl / 50% methyl siloxane phase and is not a chemically bonded or crosslinked type. Therefore, this product can be used in established methods where crosslinked polymers or chemically bonded polymers are not required. Since this product is neither chemically bonded nor crosslinked, solvent cleaning is not recommended. 【Features】 ■ 50% phenyl and 50% methyl siloxane ■ It has undergone testing based on the industry's very strict QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative and quantitative results. ■ For details on QC test conditions, including test mixtures and chromatograms of results, please refer to the Agilent J&W GC Column Performance Summary included with each GC column. *For more information, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration