We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

column Product List and Ranking from 44 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

column Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

  1. 日本ウォーターズ(米国本社 Waters Corporation)  Tokyo//Testing, Analysis and Measurement
  2. 東ソー バイオサイエンス事業部 計測分野 Tokyo//Chemical
  3. アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  4. 4 サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K. Tokyo//Testing, Analysis and Measurement
  5. 5 関東化学株式会社 バイオケミカル部 Tokyo//Chemical

column Product ranking

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

  1. ACQUITY UPLC column 日本ウォーターズ(米国本社 Waters Corporation) 
  2. Innovative solid-phase extraction column Oasis PRiME HLB 日本ウォーターズ(米国本社 Waters Corporation) 
  3. High Purity Silica Gel HPLC Column "Mightysil Series" 関東化学株式会社 バイオケミカル部
  4. 4 HybridSPE Phospholipid Solid Phase Extraction Column メルク株式会社ライフサイエンス(シグマ アルドリッチ ジャパン合同会社)
  5. 4 ACQUITY APC Column 日本ウォーターズ(米国本社 Waters Corporation) 

column Product List

61~75 item / All 647 items

Displayed results

GC column "CP-Sil 43 CB"

An ideal column for the analysis of inductively coupled compounds! Separating aliphatic and aromatic compounds.

We would like to introduce the GC column "CP-Sil 43 CB" that we handle. It is a chemically bonded medium-polarity GC column with a liquid phase consisting of 25% cyanopropyl, 25% phenyl, and 50% dimethylpolysiloxane. It is equivalent to the OV-225 stationary phase used in packed columns and efficiently separates aliphatic and aromatic compounds. 【Features】 ■ Medium-polarity column with distinctive selectivity ■ Separates aliphatic and aromatic compounds ■ Long lifespan with chemically bonded liquid phase *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "CP-1301"

Excellent reproducibility and good deactivation! Thin film GC columns suitable for the analysis of herbicides, pesticides, and pharmaceuticals.

We would like to introduce the GC column "CP-1301" that we handle. This column features a non-covalently bonded phase consisting of 6% cyanopropylphenyl and 94% dimethylpolysiloxane. This medium-polarity column is suitable for the analysis of herbicides, pesticides, and pharmaceuticals. 【Features】 ■ Column with a non-covalently bonded phase of 6% cyanopropylphenyl and 94% dimethylpolysiloxane ■ Medium-polarity thin film GC column ■ Excellent reproducibility ■ Good inertness *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-WaxFF"

Chemical bonding and cross-linking type! Exhibits excellent performance, especially in complex fragrance analysis.

"DB-WaxFF" is a microbore column of Agilent's standard DB-Wax column, specially tested to maximize reproducibility between columns. It demonstrates excellent performance, particularly in complex fragrance analyses. The lower temperature limit is 20°C, which improves the separation of low-boiling compounds. The reproducibility between columns is significantly superior to other microbore columns. 【Features】 ■ Polyethylene glycol (PEG) ■ Equivalent to USP Phase G16 ■ High polarity ■ Chemical bonding/cross-linking type ■ Alternative to HP-WAX ■ Solvent washability *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-FFAP CB"

It is possible to analyze free fatty acids from C2 to C24 in a single measurement without derivatization!

The "CP-FFAP CB" is a column that guarantees the analysis of free fatty acids. Due to its high maximum operating temperature of 250°C, it is possible to analyze free fatty acids from C2 to C24 in a single measurement without the need for derivatization. By using a chemically bonded liquid phase, it prevents the breakdown of the liquid phase due to acids. Even with large continuous injections of water or organic solvents, the column does not get damaged. 【Features】 ■ Guarantees the analysis of free fatty acids ■ Analyzes fatty acids from C2 to C24 in one go without the need for derivatization ■ High durability against water and organic solvents ■ Chemically bonded for long lifespan *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Carbowax 20M/HP-20M"

Temperature range is 60 to 220°C! Suitable for alcohol, free acids, ethers, glycols, and solvents.

"Carbowax 20M/HP-20M" is a polyethylene glycol (PEG) column equivalent to USP Phase G16. The temperature range is 60 to 220°C, suitable for alcohols, free acids, ethers, glycols, and solvents. Since it is neither chemically bonded nor cross-linked, solvent washing is not recommended. DB-WAX is chemically bonded and can be used as a substitute for HP-20M. 【Features】 ■ Polyethylene glycol, MW 20,000 ■ Equivalent to USP Phase G16 ■ All of our GC columns undergo testing based on the industry's very strict QC specifications regarding column bleed, sensitivity, and efficiency ■ Capable of obtaining highly reliable qualitative/quantitative results ■ Equivalent product: Rt-CW20M F&F *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CAM"

Base-inactive treated polyethylene glycol! Designed specifically for amine analysis.

The "CAM" is a column that can achieve excellent peak shape for primary amines. It can be used as a substitute for HP-BasicWax. Since this column is neither bonded nor cross-linked, solvent washing is not recommended. It is made of base-inactive treated polyethylene glycol and is specifically designed for amine analysis. 【Features】 ■ Base-inactive treated polyethylene glycol ■ Specifically designed for amine analysis ■ Excellent peak shape for primary amines ■ Can be used as a substitute for HP-BasicWax ■ All of our GC columns undergo testing based on the industry's very strict QC specifications for column bleed, sensitivity, and efficiency ■ Capable of obtaining highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Lowox"

Unique selectivity for a wide range of oxygen-containing compounds! Suppressing particle detachment and maintaining detector performance.

"Lowox" is a highly polar column suitable for the measurement of oxygen-containing compounds. It provides solutions for the chemical and petrochemical industries, particularly suitable for trace analysis of oxidizing impurities contained in gas and liquid hydrocarbon streams. It is appropriate for preventing catalyst contamination by oxygen-containing compounds and for process/online applications (such as measuring methanol in crude oil in accordance with ASTM D7059). 【Features】 ■ Unique selectivity for a wide range of oxygen-containing compounds ■ Suppresses particle shedding to maintain detector performance ■ Proven performance in process and portable GC applications (ASTM D 7059) ■ Analyzes trace levels of oxidizing impurities in gas and liquid hydrocarbon streams ■ Highly polar ■ Suitable for monitoring catalyst contamination by oxygen-containing compounds *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-Petro"

Cleaning with solvent is possible! Introducing columns with chemical bonds and cross-linking types.

"DB-Petro" is a 100% dimethylpolysiloxane phase precisely designed for the analysis of PONA, PIANO, and PNA generated in petroleum processing. It allows for solvent cleaning with chemical bonding and crosslinking types. It has also been tested based on the industry's very strict QC standards. One of its features is a wide operating temperature range of -60 to 325/350°C, enabling highly reliable qualitative and quantitative results regarding column bleed, sensitivity, and efficiency. 【Features】 ■ 100% dimethylpolysiloxane ■ PONA, PIANO ■ High separation capability ■ Chemical bonding, crosslinking type ■ Solvent cleaning possible *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-2887"

Low bleed with high-speed analysis! Introducing columns that allow solvent cleaning with chemical bonds and crosslinking types.

The DB-2887 is a column specially designed for pseudo-distillation in accordance with ASTM method D2887. It features fast conditioning, rapid analysis, and low bleed, with a chemical bond and cross-linked type, and excellent performance between columns. With a wide operating temperature range (-60 to 350°C) and tested based on the industry's very strict QC standards, it stands out for its performance and ease of use, and solvent washing is also possible. 【Features】 ■ 100% Dimethylpolysiloxane ■ Specially designed for pseudo-distillation (SIMDIS) using ASTM method D 2887 ■ Faster conditioning and analysis with lower bleed compared to packed columns ■ Chemical bond and cross-linked type, allowing for solvent washing ■ Capable of obtaining highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 5 CB for Sulfur"

Achieving high-quality data and low detection limits! Providing accurate analytical results based on volatility.

The "CP-Sil 5 CB for Sulfur" is a column optimized for the analysis of volatile sulfur compounds. It achieves high productivity in trace analysis of sulfur compounds up to C7 mercaptans. With a non-polar phase, it can accurately separate based on volatility. High inertness allows for the elution of sulfur dioxide, resulting in high-quality data and low detection limits. 【Features】 ■ Optimized for the analysis of volatile sulfur compounds ■ Achieves high productivity in trace analysis of volatile sulfur compounds up to C7 mercaptans ■ Provides accurate analytical results based on volatility due to the non-polar phase ■ Achieves high-quality data and low detection limits through the elution of SO2 due to high inertness ■ Capable of obtaining highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Squalane"

Very effectively separates C4 to C10 hydrocarbons! Provides a low-polarity liquid phase through reliable identification.

We would like to introduce 'CP-Squalane' handled by Agilent Technologies. It separates C4 to C10 hydrocarbons very effectively based on reliable identification using retention index. It provides a low-polarity liquid phase. Please feel free to contact us when you need assistance. 【Features】 ■ Very effective separation of C4 to C10 hydrocarbons ■ Reliable identification based on retention index ■ Low-polarity liquid phase *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Select Permanent Gases/CO2"

The maximum operating temperature is 300°C! You can choose the column size according to the purpose of the analysis.

The "Select Permanent Gases/CO2" is a column that connects CP-Molsieve 5Å for permanent gas analysis and CP-PoraBOND Q for carbon dioxide analysis in parallel. It allows for the selection of column size according to the analysis purpose, such as rapid analysis, low concentration analysis, and quantification of argon and oxygen. It performs the analysis of permanent gases and carbon dioxide in a single run. 【Features】 ■ Reduces analysis costs with isothermal separation above 40℃ ■ Maximum operating temperature is 300℃ ■ Although it is a parallel column, there is one injector and one detector *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Wax for Amines"

Introduction of columns compliant with EPA Method 607 featuring symmetrical peaks due to base reagent inactivation!

"CP-Wax for Amines" is a column designed for the analysis of C4 to C10 amines, diamines, and aromatic amines. It complies with EPA Method 607 and features symmetrical peaks due to the inactivation of basic reagents. Please feel free to contact us if you have any inquiries. 【Features】 ■ For the analysis of C4 to C10 amines, diamines, and aromatic amines ■ Complies with EPA 607 ■ Symmetrical peaks due to the inactivation of basic reagents *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Smart key equipped 8890 GC column

Achieving long-term column performance and accurate separation through strict quality control specifications and testing!

Agilent Technologies, Inc. offers GC columns with smart keys. The smart key allows for monitoring of the column profile and the usage status of the GC column. Additionally, a wide range of stationary phases is available, from ultra-nonpolar and polyethylene glycol (PEG) to stationary phases tailored for specific applications. 【Features】 ■ The smart key enables automatic detection of instrument configuration and monitoring of usage status during operation, supporting the automation of method development. ■ A wide selection of stationary phases (low polarity, medium polarity, high polarity, application-specific stationary phases) is available. ■ Strict quality control specifications and testing ensure long-term column-to-column performance and accurate separations. ■ Optimization of the GC flow path with Agilent Ultra Inert liners, low bleed septa, certified vials, and gas screen filters. ■ Designed for the Agilent 8890 GC system. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ZORBAX RRHD column

A new level of sensitivity and separation capability! It aligns many binding phases and flexibly responds to various analyses.

The 'ZORBAX RRHD Column' we handle achieves true high-resolution analysis without compromising stability. Thanks to its excellent flexibility, it is possible to increase the flow rate to the column's limit without reducing separation efficiency or quality. With more than 12 types of bonded phases available, including HILIC, you can select the appropriate column according to your analytical needs. 【Features】 ■ Stability up to 1200 bar: Stable use with UHPLC equipment is possible. ■ Separation capability: Stable high-resolution analysis and scalability are achieved with 1.8 μm particles, making method conversion with 3.5 μm and 5 μm particles easy. ■ More reliable compound identification: High-resolution chromatograms and a column with an inner diameter of 2.1 mm enhance MS separation capability. ■ A wide range of selectable bonded phases: By combining ZORBAX and Poroshell 120 families, it becomes easier to accommodate various samples and facilitate method conversion. *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration