We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Transformer.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Transformer Product List and Ranking from 80 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Nov 05, 2025~Dec 02, 2025
This ranking is based on the number of page views on our site.

Transformer Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Nov 05, 2025~Dec 02, 2025
This ranking is based on the number of page views on our site.

  1. 松田精機 Hyogo//Manufacturing and processing contract
  2. null/null
  3. UL Japan Tokyo//Testing, Analysis and Measurement
  4. 4 ジェーピーシー Tokyo//Electronic Components and Semiconductors
  5. 5 深井製作所 Tochigi//others

Transformer Product ranking

Last Updated: Aggregation Period:Nov 05, 2025~Dec 02, 2025
This ranking is based on the number of page views on our site.

  1. Film polishing device "SP-50 type" 松田精機
  2. Film polishing device "SP-100 type" 松田精機
  3. Honeycomb Embossed "embrella" 深井製作所
  4. 4 Extra Edition: What is "Trans" that you can't ask about now? For Complete Beginners Vol. 3
  5. 5 TOGA harmful gas purification device TOGA つくば研究支援センター

Transformer Product List

166~180 item / All 228 items

Displayed results

OI Trans

OI Transformers are custom products of Musashino Tsukou, engaged in the design, manufacturing, and sales of various transformers and reactors.

By combining a rectangular-shaped core and a strip-shaped core, we have achieved a slim design with excellent leakage and temperature characteristics. It also has an advantage in installation space compared to the EI type. 【Products Available】 ■ Compact VA Series *For more details, please refer to the PDF document or feel free to contact us.

  • transformer
  • Transformers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Presenting Basic Knowledge Materials!] Collection of Basic Technical Materials on Transformers

We are offering a technical document summarizing essential basic knowledge for considering transformers (voltage converters) for free!

This document introduces the basic technology of transformers. It explains the types of transformers, types of reactors, classification based on transformer structure, types of insulation for transformers, constituent materials of transformers, main types of transformers and their characteristics, and various inspection methods. For any inquiries regarding transformers, please contact Musashino Tsukou, which has been in business for 60 years. 【Contents (excerpt)】 ■ What is a transformer ■ Types ■ Principles ■ Classification based on transformer structure ■ Types of insulation for transformers *For more details, please refer to the PDF document or feel free to contact us.

  • transformer
  • Transformers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Principle of transformers

Composed of two windings independent of the iron core! Here is an introduction to the principles of transformers!

I will introduce the principles of a transformer. A transformer consists of a core made of iron and two independent windings. The winding connected to the power source is called the primary winding, and the winding connected to the load is called the secondary winding. When an alternating voltage is applied to the primary winding (P), a current flows through it (referred to as the excitation current), which generates a magnetic flux within the core. This change in magnetic flux induces a voltage in the secondary winding (S), and the induced voltages V1 and V2 in the primary and secondary windings are determined by the ratio of the number of turns in the primary winding N1 to the number of turns in the secondary winding N2. When a voltage is applied to the primary winding, a voltage proportional to the number of turns is induced in the secondary winding, and by changing N1 and N2, the ratio of the primary voltage to the secondary voltage can be arbitrarily altered. *For more details, please refer to the PDF document or feel free to contact us.*

  • transformer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Classification by the structure of transformers

Introducing the structure of "external iron type transformers" and "internal iron type transformers"!

I will introduce the classification of transformers based on their structure. Transformers are constructed using a combination of a core and windings. "External core transformers (including wound core types)" have two or more magnetic circuits surrounding the windings. They have an appearance where the core is located outside the windings. "Internal core transformers" have a single magnetic circuit with windings arranged around it. They have an appearance where the core is located inside the windings. *For more details, please refer to the PDF document or feel free to contact us.

  • transformer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Insulation type of transformer

The temperature rise limit is defined by the insulating materials used! An introduction to the types of insulation for transformers.

Transformers are reliable and long-lasting devices, but prolonged use can lead to deterioration of the winding insulation and insulating materials due to temperature effects. They are also significantly affected by the ambient temperature in which they are used. To ensure safe long-term use, temperature rise limits are established based on the insulating materials used, and each type of insulation material has its own specified temperature rise limit. The maximum allowable temperature, under rated conditions, is the temperature rise limit of the insulation type plus the reference ambient temperature (40°C). When installed and used in control panels, it is generally necessary to consider that the internal temperature rise of the panel can be 5 to 10°C. *For more details, please refer to the PDF documentation or feel free to contact us.

  • transformer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Trans Reactor Custom-Made Service

We will support the introduction from the specification review and design stage!

We offer custom-made transformers and reactors. We support you from the specification consideration and design stage, and can respond to a wide variety of customer requests, including the application of international safety standards and the reproduction of other companies' off-the-shelf products. Please feel free to contact us with your requests. 【Features】 ■ Custom-made to match usage conditions and product specifications ■ Support from transformer selection and capacity calculation to implementation ■ Comprehensive support from design compliant with international safety standards to standard application ■ Proposals for reproduction and improvement of other companies' off-the-shelf products ■ Flexible response to small lot and prototype projects *For more details, please contact us.

  • transformer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

コイルボビン式巻鉄心変圧器『NCWトランス』

狭いスペースにトランスを設置したい!省スペース・軽量・高効率を実現

★☆2022年4月1日より本社・工場の電気は100%再エネ電気を採用しております。 日幸電機の製品は【CO2フリー電気から生まれる電源トランス】へ★☆ 『NCWトランス』は、“ロ”の字型のコイルボビンに巻線がされ、 コイルボビンの両端に帯状の珪素鋼板が巻き付けられた巻鉄心変圧器。 優れた鉄心素材をムダなく活用しているため、装置重量の大幅削減 作業効率の大幅アップが期待されます。 さらに、1次コイルと2次コイルが完全に独立しているため、高い絶縁性能を実現しました。 ※詳しくはPDF資料をご覧いただくかお気軽にお問い合わせ下さい。 ★☆★☆イプロス未登録のお客様の問い合わせに関して★☆★☆ イプロス未登録の方のお問い合わせは、 本文下にある関連リンク 【日幸電機株式会社問い合わせフォーム(※イプロス未登録の方はこちらからお問い合わせください)】 よりお問い合わせください ☆★☆★↓↓↓↓↓↓↓↓↓↓↓↓↓↓↓↓☆★↓↓↓↓↓↓↓↓☆★ ☆★☆★↓↓↓↓↓↓↓↓↓↓↓↓↓↓↓↓☆★↓↓↓↓↓↓↓↓☆★

  • transformer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Wound Iron Core Transformer "NCW Trans" (Nikko Electric)

No joints, minimal leakage flux! A structure where the primary winding, secondary winding, and core are separately insulated!

The "NCW Transformer" is a wound iron core transformer designed based on the concept of winding an iron core around a coil bobbin, achieving space-saving, lightweight, and high efficiency. The structure features winding on a "U" shaped coil bobbin, with strip-shaped silicon steel sheets wrapped around both ends of the coil bobbin. It allows for efficient iron core winding operations and winding work using an automatic winding machine. 【Features】 ■ Efficiency in iron core winding operations ■ Winding work possible with an automatic winding machine ■ Complete separation of primary and secondary windings ■ Use of oriented silicon steel sheets ■ Full utilization of iron core performance due to no cuts ■ No joints, resulting in minimal leakage flux *For more details, please refer to the PDF document or feel free to contact us.

  • transformer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Trans

A rich lineup! Based on your requests, we will propose suitable products for you.

We would like to introduce the "Transformers" handled by Nippon Pulse Industry. Our lineup includes small "High-Frequency Pulse Transformers" used for applications such as IGBT drives and signal transmission, as well as "High-Frequency High-Voltage Transformers," "Flyback Circuit Transformers," and "High-Frequency Transformers." Our company designs, manufactures, and sells various transformers, and we will propose suitable products based on our customers' requests. 【Lineup (Excerpt)】 ■ High-Frequency Pulse Transformers ■ High-Frequency High-Voltage Transformers ■ Flyback Circuit Transformers ■ Switching Transformers ■ High-Frequency Transformers *For more details, please refer to the PDF materials or feel free to contact us.

  • transformer
  • Transformers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

High-speed transformer for drives "FDT Series"

Can be used in circuits requiring high voltage resistance and compact size! Ultra-compact high voltage resistant product with a core size of 8mm.

We would like to introduce our high-speed transformer for drive applications, the 'FDT Series'. The operating temperature range is -10°C to +70°C, and the storage temperature range is -20°C to +105°C. It features a low input-output capacitance and is an ultra-compact high-voltage product with a core size of 8mm. It can be used in power MOSFET & IGBT drive circuits, high-voltage signal isolation for feedback applications, and other circuits where high voltage and compact size are required. 【Features】 ■ Ultra-compact high-voltage product (core size 8mm) ■ Low leakage inductance ■ Low input-output capacitance *For more details, please refer to the PDF materials or feel free to contact us.

  • transformer
  • Transformers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Differential Transformer "ST-05"

It is compact, lightweight, requires little driving power, and is highly durable.

The "ST-05" is a differential transformer that provides non-contact displacement output. The output voltage is proportional to the displacement of the core, offering a high output voltage and infinite resolution. Additionally, it is compact, lightweight, requires minimal driving force, and is highly durable. 【Features】 ■ Non-contact displacement output ■ Output voltage is proportional to core displacement ■ High output voltage ■ Infinite resolution ■ Compact and lightweight with minimal driving force required *For more details, please refer to the external link page or feel free to contact us.

  • electromagnet
  • transformer
  • Transformers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Trans "BVA"

A lineup ranging from a maximum capacity of 1.0 VA to 50.0 VA! With a wide variety of options, you can also freely choose the terminals.

We would like to introduce the transformer "BVA" that we handle. It features a channel frame type using a high-efficiency coaxial bobbin, with a wide variety of options available. You can also freely choose the terminals. We have a large lineup, including the "28-11-AC" with a maximum capacity of 1.0VA, the "60-25-AC" with a maximum capacity of 20.0VA, and the "4G-40-AC" with a maximum capacity of 50.0VA. 【Features】 ■ Uses a high-efficiency coaxial bobbin ■ Channel frame (band cover) type ■ Wide variety of options ■ Terminals can be freely selected *For more details, please refer to the PDF document or feel free to contact us.

  • transformer
  • Converters and Transducers
  • Transformers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Trans "BHE"

Introducing a transformer that meets international safety standards! Split bobbin, horizontal type (band).

The "BHE" is a channel frame (band cover) type transformer. The primary and secondary windings are separated to comply with international safety standards. The maximum capacity conditions are 50/60Hz, with one circuit for input and output, and we offer maximum capacities ranging from 1.0VA to 50.0VA. 【Features】 ■ Separation of primary and secondary windings ■ Compliance with international safety standards ■ Channel frame (band cover) type ■ Safety standards: PSE UL CSA *For more details, please refer to the PDF materials or feel free to contact us.

  • transformer
  • Converters and Transducers
  • Transformers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Trans "BVE"

Split primary and secondary windings! Channel frame type transformer compliant with international safety standards.

We would like to introduce the transformer "BVE" that we handle. It is a channel frame (band cover) type transformer, with the primary and secondary windings separated, compliant with international safety standards. We offer a lineup ranging from a maximum capacity of 1.0VA to 50.0VA, with the maximum capacity conditions being 50/60Hz, and each input and output having one circuit. 【Features】 ■ Primary and secondary windings are separated ■ Compliant with international safety standards ■ Channel frame (band cover) type ■ Safety standards: PSE UL CSA *For more details, please refer to the PDF document or feel free to contact us.

  • transformer
  • Converters and Transducers
  • Transformers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Trans "BHI"

The terminal has only lead wires! We introduce a bobbin-structured transformer with an insulating cover.

"BHI" is a channel frame (band cover) type transformer. The terminals are only lead wires. The primary and secondary windings are separated, and it features a bobbin structure with an insulating cover, complying with international safety standards. The maximum capacity conditions are 50/60Hz, with one circuit for input and output, and we offer maximum capacities ranging from 5.0VA to 40.0VA. 【Features】 ■ Channel frame (band cover) type ■ Separation of primary and secondary windings ■ Bobbin structure with insulating cover ■ Complies with international safety standards *For more details, please refer to the PDF document or feel free to contact us.

  • transformer
  • Converters and Transducers
  • Transformers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration