We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Mass spectrometer.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Mass spectrometer Product List and Ranking from 17 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

Mass spectrometer Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

  1. 一般財団法人材料科学技術振興財団 MST Tokyo//Testing, Analysis and Measurement
  2. ブルカージャパン ダルトニクス事業部 微生物同定・菌株識別 Kanagawa//Testing, Analysis and Measurement
  3. ATONARP INC. Tokyo//Electronic Components and Semiconductors
  4. 4 LECOジャパン Tokyo//Testing, Analysis and Measurement
  5. 5 山善 Osaka//Machine elements and parts

Mass spectrometer Product ranking

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

  1. Overview and characteristics of LDI-MS (Laser Desorption Ionization Mass Spectrometry) 一般財団法人材料科学技術振興財団 MST
  2. Rapid Microbial Identification "MALDI Biotyper" ブルカージャパン ダルトニクス事業部 微生物同定・菌株識別
  3. [Analysis Case] Qualitative Analysis of Acrylic Resin 一般財団法人材料科学技術振興財団 MST
  4. Introduction to the Technical Note of the Mass Spectrometry Device ASTON ATONARP INC.
  5. 4 [Analysis Case] TOF-SIMS Analysis of Solder Separation Cross Section 一般財団法人材料科学技術振興財団 MST

Mass spectrometer Product List

46~48 item / All 48 items

Displayed results

Qualitative Analysis of Organic Materials Used in Perovskite Solar Cells

We will conduct qualitative evaluation of organic materials, focusing on hall transport materials, using LC/MS.

Perovskite solar cells are composed of various types of organic materials depending on their purpose and role. This document presents an example of qualitative analysis of organic materials using LC/MS. By utilizing high-resolution MS spectra and MS/MS spectra, we were able to identify hole transport materials and additives in the hole transport layer. It is also possible to quantify the identified materials by comparing between samples or using standard samples. Measurement method: LC/MS Product field: Solar cells Analysis purpose: Composition evaluation and identification For more details, please download the document or contact us.

  • Contract measurement

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Analysis Case] Component Evaluation of Positive and Negative Electrode Binders in Secondary Batteries

Identification of organic substances using TOF-SIMS and GS/MS.

The binder for lithium-ion secondary batteries not only serves as an adhesive between active materials but also needs to be insoluble in the electrolyte. Therefore, the selection of suitable materials for both the positive and negative electrodes is crucial. This document presents cases where the components of the binders used in each electrode sheet were identified by measuring the positive electrode binder using TOF-SIMS and the negative electrode binder using GC/MS, and then comparing the results with a materials library database.

  • c0594.jpg
  • c0594-2.jpg
  • Contract Analysis
  • Contract measurement

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Analysis Case] Off-flavor Analysis from Food (SIFT-MS)

We will introduce a case where 2,4,6-trichloroanisole (TCA) was quantified using SIFT-MS.

【Sample Analysis】 Banana 1 bunch (5 pieces) 【Analysis Results】 A bunch of bananas and high-purity nitrogen gas were placed in a 10L Tedlar bag and left at room temperature for about 24 hours. After that, the TCA concentration inside the bag was measured for about 10 minutes using SIFT-MS. As a result, the average concentration of TCA inside the bag was 10 ppbv, allowing for quantification of trace amounts of TCA without complex pre-treatment such as concentration.

  • Contract measurement

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration